NICE Sumo SU2000 – drive for sectional/overhead doors up to 35 m²
| Product availability: | within 3 days | We usually dispatch goods within 3 days. |
|---|
within 3 days
€549.42 including VAT
| Weight |
|---|
| 10 kg |
Description of NICE Sumo SU2000 – drive for sectional/overhead doors up to 35 m²
NICE SUMO SU2000 is a shaft-mounted operator for sectional garage doors or suspended sliding gates, including those with two counter-moving leaves. It has a 24 V DC motor, a magnetic encoder, torque of 120 Nm and a speed of up to 16 rpm. The sectional door area limit is 35 m².
The SU2000 does not include a control unit. For a counterbalanced sectional door add separately NICE DPRO924, which powers the motor and controls the accessories. A suspended sliding gate requires a separately selected, suitable control unit; the DPRO924 is intended for counterbalanced sectional doors. The 230 V AC mains supply connects to the control unit, not directly to the motor. The operator is non-reversible and is released manually using the cord release.
| Quick navigation | |
|---|---|
| Operator selection | Accessories |
| Package contents | Installation |
| Manual release | Wiring |
| Initial startup | Settings |
| Remote controls | Diagnostics |
| Reset | Maintenance |
| Specifications | PDF manual |
Control unit and accessories
The following wiring and setup instructions apply to a counterbalanced sectional door with the SU2000, DPRO924 and incremental encoder. For an older installation fitted with an A924, use its own terminals and manual; these control units do not share interchangeable wiring.
| What | Why | Type |
|---|---|---|
| Control unit | For a counterbalanced sectional door; wiring and protection according to operating mode. | |
| Photocells | Standard NC relay output, Phototest wiring. | |
| Warning light | Separate 24 V flashing lamp on OUT1. | |
| Radio receiver and remote control | SM socket, selection and pairing. | |
| Backup battery | DPRO924 emergency power supply after programming. | |
| Drive adapter | Direct adapter or chain, depending on the installation. |
The DPRO924 does not have BlueBUS: EPMB is not a direct replacement for the relay-output EPM models. The PS124 battery used with SOON operators is not a backup battery for the DPRO924.
Safety equipment required for the DPRO924 operating mode
| Mode | Required protection |
|---|---|
| Hold-to-run control | The control must be within sight of the gate. If it is accessible to the public, protect it against unauthorised use, for example with a key switch. |
| Semi-automatic operation | An active safety edge to limit forces, connected to the safety input. |
| Automatic closing | An active safety edge to limit forces and at least one pair of photocells. |
Simply programming the devices or adjusting sensitivity does not replace protective devices and safety tests.
When to choose the SUMO SU2000
The SU2000 is suitable for larger, mechanically counterbalanced gates in commercial and industrial settings. Selection depends on the resistance to movement, drums, shaft, drive ratio and required number of operating cycles.
| Requirement | What it means |
|---|---|
| Area up to 35 m² | The upper limit for a sectional door; it does not automatically determine the weight or length of a suspended gate leaf. |
| Torque: 120 Nm | Assess the torque required at the shaft for the entire gate, including startup. |
| Speed: 7.5–16 rpm | Motor speed range; gate speed depends on the drum and any reduction gearing. |
| Duty cycle: 50% | This does not mean continuous operation without breaks or a universal number of cycles per hour. |
| IP44 rating | Protect the motor from flooding and unsuitable environments; the standalone DPRO924 is rated IP55 when its enclosure is properly closed. |
SU2000 operator and separate control unit
| SUMO SU2000 | DPRO924 |
|---|---|
NICE SU2000![]() Up to 35 m², 120 Nm; the control unit is sold separately. | NICE DPRO924![]() Control unit for the SUMO 24 V motor on balanced sectional doors; relay-type photocells. |
What’s included with the SUMO SU2000
Standalone motor with encoder, mounting bracket, drive key, mounting hardware, and cord release with operating handle. The DPRO924, radio receiver, photocells, and chain drive are not automatically included with the motor.
Installing the operator
Disconnect the mains supply and backup battery before carrying out any work. The gate must be mechanically safe and properly balanced, with functional guides and stops. For a sectional door, also check the springs and lifting cables. The operator will not fix a gate that is difficult to move.
Direct shaft mounting
The NICE SUMO SU2000 operator mounts directly on the sectional door shaft Ø 25.4 mm. For shafts Ø 31.75 / 35 / 40 mm, use NICE CRA9. The mounting bracket is included; select wall anchors to suit the substrate. The Ø 25.5 mm opening in the motor does not indicate a different recommended shaft diameter.
- Remove the cover, prepare the cable glands, and hold the release lever in place during installation; secure it in the installation position as shown.
- Slide the motor onto the shaft, aligning the keyways. Insert the drive key and secure it against slipping out with a suitable collar.
- Screw the bracket to the operator and anchor it to the wall so the operator remains parallel to the wall.
- Release the installation lock on the release lever, return it to the operating position, and check the cover and release mechanism.
For a steel structure, use M8 bolts in grade 6.8 or A2-50. Anchors in other substrates must safely withstand a tensile load of 1,000 N; select the anchor type to suit the structure.

SUMO: cable glands, release lever installation position, drive key, and bracket
Offset mounting using a chain
When there is not enough room for direct mounting, use a shaft with an 18-tooth sprocket NICE CRA1 in the operator and a sprocket on the gate shaft. The drive uses a 1/2″ × 5/16″ chain NICE CRA3 (1 m) or NICE CRA4 (5 m), with connector NICE CRA2. Use brackets to mount the operator off-axis NICE CRA8.
| Ratio | Components and outcome |
|---|---|
| 1:1 | NICE CRA1 + NICE CRA7 (18 / 18 teeth). No speed reduction. |
| 1:2 | NICE CRA1 + NICE CRA6 (18 / 36 teeth). The gate shaft rotates more slowly; the transmitted torque and gate structure must be assessed. |
The sprockets must be in the same plane, and the chain must be properly tensioned and protected against trapping hands or clothing. Changing the drive ratio does not automatically change the allowable gate area. Dimensions, balance, travel, and the complete assembly must be assessed together.
Position the chain at least 2.4 m above the floor and out of reach; if this is not possible, fit a protective cover. Under a load of 4,000 N, the shaft supporting the sprocket must deflect by no more than 2 mm.

SUMO: vertical chain drive using CRA1, CRA6, or CRA7 and CRA8 brackets
Chain drive arrangement for a suspended sliding gate
For a suspended gate, the loop consists of a shaft with a sprocket NICE CRA1, a tensioner with an idler sprocket NICE CRA5, chain NICE CRA4 and connectors NICE CRA2. Attach the gate leaf to the upper or lower chain run, depending on the direction of travel. For two opposing gate leaves, attach one to the upper run and the other to the lower run.
This is a custom-designed chain assembly. The sectional door area limit does not determine the allowable weight or length of a suspended gate leaf. Check the travel resistance, force transmission, travel path, mechanical stops, and protection of pinch points.
For a suspended gate, the control unit must also be checked separately for suitability. The DPRO924 wiring and setup instructions below apply to a balanced sectional door. According to the manufacturer, the SUMO motor is intended for a gate that can be moved manually along its entire travel with a force of less than 300 N; the specific suspended-gate assembly must be assessed as a whole.

SUMO: installing a horizontal chain loop for a suspended gate
Manual release and return to motorized operation
The SU2000 uses the supplied nylon cord and handle for release from floor level; the cord can be no longer than 6.5 m. Release only a stationary, balanced gate.
- Pull the handle down to position 1 as shown.
- Move the gate manually with care.
- Before operating it electrically, return the release mechanism to its original locked position and check that the drive is engaged.

SUMO SU2000: floor-level cable release, position 1 for manual operation
External release is handled separately: NICE KA1 (6 m steel cable) and NICE KIO or NICE KIOMINI. This does not replace the requirement to correctly install the supplied release mechanism; adapt the cable routing and mechanical connection to the drive.
With SUMO and DPRO924, position synchronisation must be restored after moving the gate manually. If the control unit was switched on during release, it will register the release. To restore synchronisation, run the gate to the stored fully closed position; until synchronisation is restored, hold the command to open the gate. Keep the gate under observation and do not bypass the safety devices.
Wiring the SU2000 with DPRO924
Disconnect both the mains supply and PS224 before starting work. The motor cable and encoder cable are separate circuits. These procedures apply to a balanced sectional door with one SU2000 motor and a DPRO924.

DPRO924: motor, incremental encoder, commands, relay photocells, warning light and safety circuit
Cabling and cable lengths
| Cable run | Cable / maximum length |
|---|---|
| Mains supply to DPRO924 | 3 × 1.5 mm² / 30 m. |
| Motor | 3 × 2.5 mm² / 10 m; depending on the motor terminals and protective wiring. |
| Incremental encoder | 2 × 1 mm² / 10 m; route separately from power cables. |
| Warning light | 2 × 0.5 mm² / 20 m. |
| Photocells | 4 × 0.5 mm² / 20 m; use the specific branches shown in the selected wiring diagram. |
| Command switch | 2 × 0.25 mm² / 20 m or 4 × 0.5 mm². |
| Antenna | RG58 / maximum 10 m, 5 m or less recommended. |
For a mains cable run longer than 30 m, use 3 × 2.5 mm² and ensure protective earthing near the automation system. Select the cable type and protection for the electrical supply according to the installation.
Terminals and accessory polarity
| DPRO924 terminal | Function / wiring |
|---|---|
| MOTOR 1 / 2 / 3 | 1 and 2 – 24 V DC motor output; 3 – protective earth. The polarity at the motor output changes with the direction of movement. Do not connect 230 V mains to the motor terminals. |
| Incremental encoder | Two encoder signal wires; non-polarised. Not an auxiliary power supply. |
| GND (1) / 24 V (2) | 1 GND = negative (−), 2 24 V = positive (+); 24 V DC, −30% / +50%, maximum 200 mA for all accessories combined. |
| Phototest (3) | Tested positive supply for TX: 3 = positive (+), GND 1 = negative (−); 24 V DC, max. 200 mA at the Phototest output. |
| Common / COM SBY | Positive common supply for commands, 24 V DC. The Common for SbS remains active; COM SBY for Open/Close/Photo/Photo2 is switched off during Total Stand-by. This is not GND. |
| SbS / Open / Close | Voltage-free NO contacts: SbS to Common, Open and Close to COM SBY. The contacts themselves are non-polarised. |
| Photo / Photo2 | Voltage-free NC photocell contact; the common connection depends on Phototest or Stand-by. |
| STOP Safety Edge | 8.2 kΩ resistive or OSE optical safety edge. OSE: +12 V = positive, GND = negative, SIG = signal. |
| ALT | NC safety circuit. An open contact blocks operation. |
| OUT1 / OUT2 / OUT3 | OUT1 – 24 V warning light up to 25 W with separate flashing; OUT2/3 – voltage-free relay contacts for resistive loads up to 3 A. Do not assign fictitious +/− polarity to the OUT2/3 contact. |
| LIGHT on the cover board | 1 = negative (−), 2 = positive (+), 24 V DC, maximum 5 W; cable up to 2 m. The output has no short-circuit protection. |
Terminal block directly in the SU2000
SU2000: terminals 1/2 are for the motor, 3/4 for the encoder. Connect 1/2 to the DPRO924 motor output and 3/4 to the Incremental encoder input. Label Terminal 3 on the motor is not PE. According to the SU2000 wiring diagram, the third conductor of the three-core motor cable is safely insulated at the motor end. Protective earthing of the DPRO924 mains supply is still mandatory.

SUMO SU2000: motor terminals 1/2 and encoder terminals 3/4; third motor-cable conductor safely insulated
EPM photocells with Phototest
DPRO924 uses NICE EPM with a conventional relay output. For the safety function, connect on the EPM 4 COM and 5 NC; contact 3 NO is not the correct safety contact.
| Device | Power supply and contact |
|---|---|
| TX EPM | 1 = positive (+), 2 = negative (−). In Phototest mode: TX 1 → Phototest (3) DPRO924, TX 2 → GND (1) DPRO924. |
| RX EPM | 1 = positive (+), 2 = negative (−). RX 1 → 24 V (2) DPRO924, RX 2 → GND (1). RX 4 COM → 24 V (2) DPRO924; RX 5 NC → Photo or Photo2 depending on the protected area. RX terminal 3 NO is not connected to this safety function. |
| Two pairs | Assign each to the correct input. If they interfere with each other, change their position or use suitable optical shields. EPM synchronisation via SYNC requires an AC supply; do not use it with this DC wiring. |

EPM: TX/RX power supply 1 (+), 2 (−), relay contacts 4 COM and 5 NC

DPRO924: RX to GND/24 V and TX to GND/Phototest
Phototest checks the photocells before movement. After connecting them, programme the safety devices. Unused Photo or Photo2 is connected to Phototest in this diagram; this does not replace the required gate protection.
Alternative: Total Stand-by
Total Stand-by is enabled via Oview; after the set time (factory setting: 1 min), it reduces power consumption by switching off the accessories. Both TX and RX: 1 (+) → COM SBY, 2 (−) → GND (1). RX contact 4 COM → COM SBY, 5 NC → Photo or Photo2. Phototest is not performed with this wiring. Unused Photo/Photo2 is connected to COM SBY. Do not combine the two diagrams.

DPRO924: separate alternative for powering photocells with Total Stand-by
Safety edge and safety circuit
The 8.2 kΩ resistive edge is connected between SIG and GND, with no polarity. Optical OSE, according to the markings: brown wire to +12 V, green to SIG, white to GND. If the colour-coding differs, follow the markings provided by the edge manufacturer. With this resistive interface, NC contacts are connected in series with the 8.2 kΩ end-of-line resistor, and NO contacts in parallel with the resistor; the wiring must comply with the safety design. Repeat the learning procedure after making a change. The resistor must not be used to disable required protection.
Warning beacon and status indicator
For OUT1 is intended for NICE ELDC with built-in flashing, 24 V, max. 25 W. OUT1 is not an auxiliary GND/24 V pair; do not infer the polarity order from other connectors. The ELDC power-supply pair itself is not marked +/− in its diagram. Connect the antenna to the radio receiver using its connector.
The status indicator on the cover board is separate: LIGHT 1 (−), 2 (+), 24 V DC / 5 W. It goes out when the safety circuit is open, flashes 0.5 s ON / 0.5 s OFF in normal operation, and follows the OK indicator in the event of a fault. The cable must be no longer than 2 m, and the output is not short-circuit protected.

DPRO924: LIGHT 1 (−), 2 (+) on the cover button board
Backup power supply and service interface
NICE PS224 is connected to the designated DPRO924 battery connector only after installation and programming are complete. The number of operations during a power failure is not fixed and depends on the gate and battery. Oview connects via IBT4N and allows you to adjust force, sensitivity and deceleration points, and perform diagnostics. Choose accessories for the DPRO924, not the old A924.
Initial setup of the DPRO924 with SUMO
On the cover board, the switches enabling the OPEN and CLOSE buttons must be set to ON; STOP remains active at all times. Before learning, the gate should be approximately 50 cm above the floor, so the direction can be checked safely. The green OK indicator flashes about once per second; ALT/Photo/Photo2 must match the wiring.
1. Learning the safety devices
At least one safety device must be connected. For the selected operating mode, also ensure that you have the required safety equipment. Learn the devices and positions consecutively, without interruption.
- Set A1 to ON; A2/A3/A4 to OFF.
- Hold STOP for about 3 s until the OK indicator lights steady red; release it.
- When complete, set the switches to OFF and immediately continue by learning the incremental encoder.
2. Positions with an incremental encoder
- Set B2 OFF, B3 OFF; A1 ON, A2/A3/A4 OFF.
- Hold STOP for about 3 s until the indicator lights steady red, then release it.
- Use OPEN to move the gate to the desired open position before the mechanical stop. Confirm by holding STOP for 3 s: one red flash.
- Use CLOSE to move the gate to the fully closed position. Confirm by holding STOP for 3 s: two red flashes.
- To set a custom partial opening, use OPEN to move the gate to that position and confirm by holding STOP for 3 s: three red flashes. Otherwise, continue to the next step.
- Set A1 to OFF; set A3/A4 according to the operating mode and confirm by holding P1 for at least 2 s.
If OPEN closes the gate, stop, disconnect the mains and battery, swap the motor wires at outputs 1/2, and restart the learning procedure. Do not swap the encoder pair to change the direction.
3. Force learning
After setting the positions, perform complete opening and closing cycles without interruption until the unit stops alternating red/green flashes on OK during movement. An interrupted cycle is not counted. During learning, the unit uses maximum force: the area must be supervised. Repeat the learning procedure after changing the speed, deceleration points or sensitivity. Perform safety tests when complete.
The unit initially calculates the RA/RB deceleration points; adjust them via Oview. Do not set them using the SOON position-learning procedure.
Setting DPRO924 operating modes

DPRO924: block A with four switches and block B with three switches on the main board
Switches A and B are on the main board. After changing them, OK may flash red/green alternately and the unit may reject commands: confirm the correct configuration by pressing P1 for 2 s, or repeat the safety-device learning procedure. If these functions are set via Oview, the relevant DIP switches must be OFF.
DIP A – operation
| Setting | Meaning |
|---|---|
| A1 OFF, A2 OFF, A3 OFF, A4 OFF | Hold-to-run operation: movement only while the command is held. |
| A1 ON, A3/A4 OFF | Learning the safety devices and positions. For SU2000, also set A2 to OFF. |
| A1 OFF, A2 OFF, A3 OFF, A4 ON | Industrial mode: semi-automatic opening, closing with hold-to-run control. |
| A1 OFF, A2 OFF, A3 ON, A4 OFF | Semi-automatic operation after learning the positions. |
| A1 OFF, A2 OFF, A3 ON, A4 ON | Automatic closing with a saved pause time. |
| A2 ON | Reverse the absolute encoder; not used with the SU2000 incremental encoder. |
DIP B – sensitivity, speed and motor
| Switch | Status and meaning |
|---|---|
| B1 – sensitivity | OFF: disabled; ON: enabled. ON reduces the force applied when an obstacle is detected; after changing it, learn the forces and perform a measurement. |
| B2 – speed adjustment | OFF: normal operation; ON: speed adjustment mode, OK flashes orange rapidly. |
| B3 – motor type | OFF for SU2000 with encoder. ON is for a motor with electromechanical limit switches. |
Automatic closing – pause time
- After learning the positions, set A3/A4 to ON and A1/A2 to OFF.
- Hold P1 for at least 2 seconds.
- Send OPEN and wait for the gate to open fully.
- From this point, wait for the desired pause and send CLOSE. The time is saved.
To change the pause time, set A4 to OFF and confirm by holding P1 for 2 seconds; this deletes the previous pause time. Then set A4 to ON, confirm by holding P1 for 2 seconds, and repeat the opening, waiting and closing sequence.
Travel and deceleration speed
Opening, decelerated opening, closing and decelerated closing are set separately. You can use Oview or the control board buttons:
- Set B2 to ON; OK flashes orange rapidly.
- Hold P1 and send OPEN or CLOSE, depending on the direction being adjusted.
- While holding P1, adjust the current section: OPEN increases the speed by 5% per press; CLOSE decreases it by 5%.. A green OK light indicates a normal-speed section; red indicates deceleration.
- Release P1; to adjust the next movement, start again by holding it down.
- Set B2 back to OFF, complete force learning and carry out the tests.
Current monitoring is disabled while P1 is held. Supervise the gate during this procedure; do not use it to test the force against an obstacle.
Remote control and antenna
The radio receiver is plugged into the SM socket with both the mains supply and battery disconnected. Do not confuse the equipment supplied with a standalone operator with that of a complete kit: choose the receiver and transmitters according to the actual supplied configuration.
NICE OXIBD supports both unidirectional and bidirectional transmitters; a suitable unidirectional transmitter is the NICE MYGO4. An older installed receiver may use a different coding system. The same 433.92 MHz frequency alone is not enough.
In standard Mode 1, the receiver outputs are: 1 – step-by-step, 2 – partial opening, 3 – opening, 4 – closing. Mode 2 lets you assign an individual button to a selected command. For precise pairing and deletion, follow the instructions for the specific OXIBD receiver; the operator buttons do not erase its radio memory.
For the OXIBD, connect the antenna to the receiver connector according to the OXIBD antenna wiring diagram. Connect the coaxial cable's center conductor to the signal terminal and the shield to antenna ground. These are not the power supply +/− terminals.
DPRO924 diagnostics
After power-up, two slow green OK flashes indicate a motor with an incremental encoder. One slow red flash confirms a learned 8.2 kΩ safety edge; two flashes indicate OSE. Rapid green flashing after power-up may indicate that the memory has not been learned.
| Red OK flashes | Cause and check |
|---|---|
| 2 flashes | Photocell: obstruction, optics or relay wiring. |
| 3 flashes | Force, sensitivity or blocked encoder: check for mechanical resistance and inspect the encoder cable. |
| 4 flashes | STOP/ALT or release: secure the operator and check the safety circuit. |
| 5 flashes | Internal parameters: press STOP on the cover and wait at least 30 seconds. If the fault persists, contact service; if necessary, reset and relearn. |
| 6 flashes | Limit on the number of operations: wait for the unit to cool down. |
| 7 flashes | Internal electrical fault: press STOP, disconnect all power sources, and have the control board and wiring inspected by a qualified technician. |
| 8 flashes | Continuous input command: remove the cause of the stuck contact. |
| 9 flashes | The automation system is electronically locked: send the command to unlock it. |
| Other OK indications | Action |
|---|---|
| Steady red + 8 green flashes | No encoder signal. Press STOP and check the separate encoder cable. |
| Steady red + 10 green flashes | Movement time exceeded. Press STOP and check the mechanism and positions; adjust the time using Oview. |
| Red/green alternating while idle | DIP settings changed: check the configuration and confirm by holding P1 for at least 2 seconds. |
| Red/green alternating during movement | Force learning is in progress; complete full operating cycles. |
| Rapid orange flashing | B2 is ON; finish adjusting the speed and set B2 to OFF. |
Clearing DPRO924 memory
Resetting deletes settings, positions and learned safety devices. The plug-in radio receiver's memory is separate.
- With the gate stationary, set A1/A2/A3/A4 to ON; OK flashes orange rapidly.
- Hold STOP for about 3 seconds until OK stays red; release it.
- After the reset, OK flashes orange rapidly. Set all DIP switches A back to OFF; OK flashes green.
- Set the correct motor type, repeat the safety device and position learning procedures, learn the forces, and carry out the tests.
Pre-handover gate inspection
- With the operator released, check that the gate moves smoothly and is balanced. For the sectional door assembly described here, the force required for manual operation must not exceed 225 N. This is not the motor torque or the permissible impact force.
- After locking the operator, test opening, closing and STOP; the gate must not bind or strike beyond the stored limit positions.
- Test each pair of photocells at the TX, at the RX and in the centre of the beam, for example with a cylinder 5 cm in diameter and 30 cm long. Check the gate's actual response.
- Test the safety edge, safety circuit and emergency release. Measure impact forces using a suitable instrument; repeat the test after changing the force or sensitivity settings.
- Hand over the gate only after successful testing, and provide labels, release instructions and a maintenance plan. Only pass through the gate when it is fully open and stationary.
Operator and gate maintenance
Disconnect both the mains supply and the battery before each scheduled inspection. Check the bracket, anchors, wedge, shaft, release mechanism, guide components and balance; for chain drives, also check tension and wear and lubricate as required. Operate the unit only when the mechanical stops and safety devices are working.
Set the maintenance interval for the complete assembly according to usage and gate type; inspect and clean EPM photocells at least every 6 months. Repeat the tests after servicing. For a sectional door, spring or load-bearing cable faults must be repaired by a professional—not by increasing motor force.
SUMO SU2000 technical specifications
| Parameter | Value |
|---|---|
| Control unit | For a balanced sectional door, a separate NICE DPRO924; not included with the SU2000. A suspended installation requires a suitable control unit, supplied separately. |
| Motor power supply | 24 V DC; operating range 15–36 V DC. |
| Motor current draw / power consumption | 13 A DC / 500 W. This is not current drawn from the 230 V mains. |
| Torque | 120 Nm. |
| Speed | 7.5–16 rpm; settings depend on the control unit and configuration. |
| Sectional door area | Up to 35 m². |
| Duty cycle | 50%. |
| Ingress protection / temperature | SU2000 IP44; −20 to +50 °C. |
| Shaft / bore | Shaft Ø 25.4 mm; bore in motor Ø 25.5 mm. |
| Dimensions / weight | 350 × 270 × 110 mm / 10.5 kg. |
| Motor insulation thermal class | Class B. |

Dimensions of the SUMO SU2000, shaft bore and bracket adjustment range
DPRO924 power supply and limits
| Parameter | Value |
|---|---|
| Mains power supply | 230 V AC, 50/60 Hz; Class I, grounding. |
| Maximum mains power consumption | 500 W. |
| Accessory output | 24 V DC −30% / +50%, 200 mA; polarity and terminals. |
| Backup | NICE PS224. |
| Fuses | F2 T2 A; F1 automotive 20 A. Same type and rating after eliminating the cause. |
| Enclosure | IP55 when properly closed; 310 × 210 × 125 mm, approximately 4 kg. |