NICE SPIDO600 - standalone operator for garage doors


Product availability: In stock

We normally dispatch goods within 24 hours.


NICE SPIDO600 - standalone operator for garage doors NICE SPIDO600 - standalone operator for garage doors
NICE-SPIDO600-A
In stock
€156.11 excluding VAT
€192.02 including VAT

 pcs
Weight
3,80 kg

Description of NICE SPIDO600 - standalone operator for garage doors

NICE SPIDO600 is a standalone garage door opener with a 24 V DC motor, built-in control unit and radio receiver. The system is powered from a 230 V AC. Choose the rail and remote control separately, or select a complete kit.

The steel-cable-reinforced belt rail ensures quiet operation. The control unit learns the end positions, force and deceleration, and detects obstacles. In the event of a power failure, the door can be released with the cord and operated manually.

Quick navigation
AccessoriesEquipment and kits
Selection and limitsRail installation
Terminals and polarityPhotocells
Initial startupSettings
Remote controlsReset
DiagnosticsManual release
MaintenanceSpecifications
PDF manual

Accessories and control

Select safety devices based on the actual risks posed by the garage door. Obstacle detection by the opener does not replace photocells, a safety edge or force measurement during installation handover.

WhatWhyType
Control unitOpener setup, operation and servicing; the control board is built in.
RailThe opener moves a trolley with an arm and requires a compatible belt drive rail.
Taller doorChoose the rail extension according to the door type, height, area and resistance.
Up-and-over doorUp-and-over doors with counterweights require a compatible arm geometry.
  • SPA5; SPA5 is not used with spring-balanced up-and-over doors, depending on the installation type.
PhotocellsObstacle detection in the protected area. Choose the correct electrical interface.
Flashing beaconVisible indication that the door is moving, optionally with an external antenna.
Remote controlThe receiver is built in. The remote control must be stored in the receiver's memory.
Backup power supplyEnables operation during a power failure when a battery is added.
Service setupDiagnostics and more detailed settings via BusT4.

SPIDO600 opener equipment and kits

This product page offers the standalone SPIDO600. For a complete setup, also choose a rail, remote control and safety accessories. Photocells, a flashing beacon, backup power and the SPA5 arm are ordered as needed; they are not automatically included in every kit.

Standalone openerKit with rail
NICE SPIDO600
NICE SPIDO600
600 N; sectional door up to 9.6 m². Add a rail and remote control.
NICE SPIDO600
NICE SPIDO600
600 N; SR32B rail and remote control, depending on kit contents.

Which garage doors is the opener suitable for?

With the SR32B rail SR32B the approximate dimensions depend on the type of garage door. The dimensions in the table are width × height. Suitability also depends on the balance, friction and available installation space.

Door typeApproximate sizeCondition
Sectional3.7 × 2.6 mApproximately 9.6 m².
Non-protruding up-and-over3.5 × 2.4 mSPA5; area 8.4 m².
Protruding up-and-over3.5 × 3.0 mSPA5; area 10.5 m².
Spring-balanced up-and-over3.5 × 3.0 mDepending on the installation, no SPA5 is required; check the travel path and balance.

Maximum force 600 N indicates the drive's pulling force. It is not the weight of the door in kilograms. During the test with the door disconnected from the drive the force required to move it manually in either direction throughout its entire travel must not exceed 225 N. The drive must not be used as a substitute for repairing damaged springs or a poorly balanced door. The SPIDO600 also has a door weight limit of 110 kg and a maximum total area of 10.5 m²; for a sectional door, observe its lower dimensional limit.

The SR32B rail is 3.2 m long, with a useful trolley travel of 2.8 m. The door height also depends on its construction and arm. For a taller door, you can add the SR08B extension, 0.8 m long, with a longer belt; with a 4 m rail, the useful travel is 3.5 m. The extension alone does not confirm that it is suitable for a larger or heavier door. Send us the width, height, door type and required travel via contact.

Cycle count and load

The SPIDO600 is designed for home use: up to 40 cycles/day and 4 minutes of continuous operation. If operated repeatedly or subject to increased resistance, the controller may temporarily limit operation to prevent the motor from overheating. One cycle includes both opening and closing.

Installing the rail and drive

Install with the door closed and both the mains power and backup battery disconnected. The door must move smoothly by hand and remain balanced in each position when disconnected from the trolley. Address any locks that would prevent automatic movement before installation. Springs and counterweights must be adjusted by a qualified technician.

  1. Check the clearance above the door, rail length, and the strength of the wall and ceiling. Keep the drive and release cord accessible.
  2. For a two-piece rail, push both sections fully into the connector. With the preassembled SR32B this connection step is not required. Check that the trolley moves smoothly and freely along the rail.
  3. Fit the motor head to the rail and secure it with the supplied screws. The head may also be rotated 90° relative to the rail axis, as shown in the installation drawing.
  4. Adjust the belt tension. An overtightened belt can damage the drive; a loose belt causes noise and unreliable movement. When extending the rail, use the correct longer belt.
  5. Secure the front bracket to a sufficiently strong surface and suspend the rear section from the ceiling brackets. Align the rail and tighten all fasteners.
  6. With the door closed, disconnect the trolley, position the door bracket in line with the rail, and connect the drive arm. A thin panel must be suitably reinforced; the installation must withstand the drive force without deforming.
  7. Finish installing the release cord. Manually move the door through its full travel, check the clearances, then re-engage the trolley before programming.

SPIDO600 installation space: A, B, C, D and distance E

In the orientation shown:

  • A = 40–400 mm
  • B = 0–400 mm
  • C = 3 158 mm
  • D = 360 mm .

For an up-and-over door, maintain E = 65–300 mm , i.e. the distance between the rail and the highest point of the door's top edge during movement. The dimensions apply to the installation configuration shown.

Wiring and mains power supply

Use a protected socket 230 V AC, 50/60 Hz with a protective earth conductor and a means of safe disconnection. Do not cut off the supplied cable or plug. If there is no suitable socket, arrange for one to be installed with the required protection. Route low-voltage wires separately from the mains wiring and secure them against pulling and contact with moving parts.

ConnectionCable / maximum length
Warning light2 × 0.5 mm²; maximum 20 m.
AntennaSeparate RG58 coaxial cable; maximum 10 m, less than 5 m recommended.
Push button / key switch2 × 0.5 mm² for a volt-free NO command; maximum 50 m. For two contacts, use two 2 × 0.5 mm² cables or one 4 × 0.5 mm² cable.
PhotocellsTX: 2 × 0.5 mm²; RX: 4 × 0.5 mm², for power supply and NC contact. Maximum 30 m.
Safety edge2 × 0.5 mm²; maximum 20 m. OSE requires three wires according to the safety edge wiring.
Mains supply to the socket3 × 1.5 mm² up to 30 m; for longer runs, use 3 × 2.5 mm² as specified in the installation manual, with protective earthing at the automation unit.

The stated lengths apply to the relevant wiring configuration and environment. For a different safety edge or control module, also follow that device's instructions. Mains power must not be connected to accessory inputs.

Control board, terminals and polarity

The following wiring and accessory range apply to the SPA600 with a seven-segment display and PHOTOTEST terminal. Check the markings on your board before wiring. If the board has an OUT STB output instead of PHOTOTEST, use the instructions for that version.

Original SPIDO600 wiring – photocells, commands, STOP, flashing light and antenna

TerminalFunction and connection
1 – SbSVoltage-free NO contact between 1 and 7; step-by-step command.
2 – PHOTOVoltage-free NC contact between 2 and 7; opening the contact triggers a safety response.
3 – 12 V OSEPositive (+) 12 V DC for the optical safety edge, max. 15 mA. Signal to 4, negative to 5.
4 – STOPSafety input referenced to 5 – GND; NO, NC, 8.2 kΩ or OSE. The type is detected during setup.
5 – GNDNegative (−) for auxiliary power and OSE; not the mains protective earth.
6 – PHOTOTESTSwitched power supply for the photocell transmitter during testing. In PHOTOTEST mode, max. 15 mA; the function can be changed in the menu.
7 – +24 V COMMONPositive (+); auxiliary 24 V DC, tolerance −30% / +50%, total max. 100 mA between 7 (+) and 5 (−).
8 – FLASHConnect the flashing light between 8 and 7 as shown in the diagram. For one ELDC the limit is 200 mA; other output functions require a different load.
AERIALSeparate two-pole antenna connector; connect the centre conductor and shielding of the RG58 coaxial cable as shown in the diagram.

SPIDO600 auxiliary power: specific positive and negative terminals

Push button, key switch or relay

Connect only a voltage-free NO contact, such as a push button or control-module relay, to SbS. The contact connects 1 – SbS and 7 – COMMON. Do not apply the module's output voltage to the command input. If the module requires power, use 7 (+) and 5 (−) separately and observe the shared 100 mA limit.

Safety edge and STOP input

STOP halts movement and briefly reverses it. When changing a safety device, you must relearn the devices. Connect multiple NO contacts in parallel and NC contacts in series. Wire 8.2 kΩ edges and their combinations according to the specific diagram; a standard switch does not provide the same level of fault monitoring as a monitored edge.

Optical safety edge: 3 positive 12 V, 4 signal, 5 negative

Photocell wiring

SPA600 does not have BlueBUS. For standard wiring, use NICE EPM with relay contact. The EPMB model does not connect to this terminal block.

EPM connectionSPA600 terminals
TX 1 (+) and RX 1 (+)7 – +24 V COMMON (+).
TX 2 (−) and RX 2 (−)5 – GND (−).
RX 4 – COM / RX 5 – NCBetween 7 – COMMON and 2 – PHOTO. The contact is not polarity-sensitive. Leave RX 3 – NO unconnected for this wiring.

In this wiring configuration, EPM units operate at 24 V DC; do not set the jumper to 12 V. The TX + RX pair draws approximately 55 mA, which must be included in the shared 100 mA auxiliary power limit.

Wiring with the PHOTOTEST function

Before operation, PHOTOTEST checks that the photocells respond correctly. Use only a transmitter with a current draw no greater than 15 mA; this limit applies to the entire output. Check compatibility of the specific TX before moving the power connection.

WireWiring with testing
TX positive (+)6 – PHOTOTEST instead of the permanent positive supply at 7.
TX negative (−)5 – GND.
RX positive / negative7 (+) / 5 (−), permanent power supply.
RX COM / NCBetween 7 and 2 – PHOTO; NC, not NO.

In PHOTOTEST settings leave the value at 0 and relearn the devices. Standard EPM power from 7 / 5 must not be mistaken for tested wiring simply because the photocells are connected to PHOTO.

Photocell wiring with PHOTOTEST on SPA600

EPM relay photocells: power supply 1 positive, 2 negative; 4 COM and 5 NC

FLASH light, lighting and antenna

NICE ELDC connect it using its terminal block marked FLASH to 7 – COMMON and 8 – FLASH as shown in the SPA600 diagram. The standard flashing-light mode uses 12 V DC; for one ELDC LED flashing light, observe the 200 mA. The output function must be configured accordingly in programming. Do not connect a 230 V mains beacon to these terminals.

For the FLASH pair on the beacon, follow the markings on the connected device. The polarity is not marked in this ELDC detail; do not apply the orientation of the 24 V / GND auxiliary terminal block to it. Input AERIAL on the ELDC is a separate antenna: connect the coaxial cable to the control unit’s antenna connector as shown. Do not confuse the antenna with the beacon power supply.

ELDC terminals: separate FLASH and AERIAL connections

The drive also has built-in LED garage lighting. Switching the FLASH or PHOTOTEST function to lighting, a lock, or a radio channel changes the purpose of the output. The same connector must no longer serve its original device.

Initial startup and learning

First complete the mechanical installation and wiring, secure the trolley, and clear the entire movement area. Check the STOP device, photocells, and direction of travel. Position learning, force learning, and remote control pairing are separate procedures.

After power-up, the OK LED should flash about once per second; at startup, the display quickly shows 8 for 3 s. The beacon output should be off at rest.

1. Learning devices and end positions

  1. Press and hold STOP/SET for about 5 s, until the menu entry symbol flashes slowly.
  2. Press OPEN to go to item 1 – Device and position search. Press STOP/SET to start; the display flashes rapidly.
  3. Wait until device recognition is complete and the display stays lit.
  4. Press and hold OPEN to move the gate to the desired open position. Use CLOSE to adjust the position. Confirm by holding STOP/SET until the closed-position symbol shown in the illustration appears; then release.
  5. Press and hold CLOSE to move the gate to the desired fully closed position. Use OPEN to make adjustments. Press and hold STOP/SET for 5 s; the symbol flashes slowly.
  6. Use CLOSE to go to the exit symbol, then confirm with STOP/SET. Press OPEN: the gate opens and closes during automatic force learning.
  7. Wait for the process to finish. The display should stay lit. If it starts flashing again, resolve the cause and repeat the learning procedure.

Buttons and symbols for learning devices and positions on SPIDO600

Repeat learning after changing accessories

Go to installation item 1 according to the menu. Press and hold STOP/SET for about 6 s; after the devices are recognized, the display flashes slowly. Then release the button. If slow flashing does not resume, wait 15 s without pressing any buttons and repeat the procedure. Exit using the exit symbol and STOP/SET. Repeat the safety test after making a change.

Changing the direction of rotation for reverse installation

  1. Disconnect the mains and backup power supply. Press and hold STOP/SET, then restore power.
  2. Release STOP/SET 3 s after power-up. Press STOP/SET briefly to select the direction: internal LC light on = reverse direction; off = standard direction.
  3. Wait 3 s without pressing any buttons to confirm, then repeat position learning.

Force learning and the first movement test

Force learning runs an automatic opening and closing cycle at increased force. Keep people and objects away from the gate during this process. When started via SbS or radio, the internal light flashes during learning; when started using the control board buttons, it does not turn on. Force learning must be repeated after changing positions, speed, direction or the mechanical stress relief setting.

If positioning is interrupted by STOP or PHOTO, resolve the cause and continue using OPEN / CLOSE. If force learning is interrupted, resolve the cause and resume it with a movement command.

Pre-commissioning test

  • With the trolley disengaged, check manual opening and closing along the entire travel path: the required force must not exceed 225 N (approximately 23 kg-force, not the weight of the gate). Then re-engage the trolley.
  • Repeat powered opening and closing; the gate must reach the stored positions without binding or bending the brackets.
  • Check deceleration at the end positions, belt slackening after the gate stops, manual release, and re-engagement.
  • Interrupt each photocell at the TX, at the RX, and midway across the beam; check that it responds correctly as a safety device. Test all STOP devices.
  • Measure impact forces and verify the safety of the entire gate. Do not use increased force to compensate for poor mechanical operation. Repeat the measurement after changing the force setting.
  • Give the user instructions for operation, manual release, and maintenance. Only pass through when the gate is fully open and stationary.

Programming SPA600 using the display

Make adjustments while the motor is stopped. Buttons OPEN / CLOSE navigate the menu or change a value; STOP/SET selects and confirms. A lit dot distinguishes a menu item from its numerical value. The position number below indicates the item’s sequence, not the symbol shown.

  1. Press and hold STOP/SET for about 5 s, to open the menu.
  2. Use OPEN / CLOSE to select a function based on the symbol in the original illustration. Briefly press STOP/SET; the current value is displayed.
  3. OPEN / CLOSE changes the value. STOP/SET confirms it and returns to the menu.
  4. Select the exit symbol with horizontal bars and confirm with STOP/SET. If you select exit while changing a value, the change will be canceled.

Original display symbols and menu item sequence for SPA600

Item 1 is for learning devices and positions, item 9 is for erasing memory. Factory settings are highlighted in bold.

Position – parameter and purposeValues
2 – Force
Range of adjustment levels, not a value in newtons.
0 – minimum
1–4 – increasing levels
5 – factory setting
6–8 – increasing levels
9 – maximum
3 – Speed
Values are opening / closing speeds in %. Force learning follows any change.
0 – 40 / 40
1 – 50 / 50
2 – 50 / 75
3 – 50 / 100
4 – 75 / 50
5 – 75 / 75
6 – 75 / 100
7 – 100 / 50
8 – 100 / 75
9 – 100 / 100
4 – Automatic closing
Pause after opening before automatic closing.
0 – off
1 – 10 s
2 – 20 s
3 – 30 s
4 – 40 s
5 – 50 s
6 – 60 s
7 – 70 s
8 – 80 s
9 – 90 s
5 – FLASH (OUT1)
The function must match the load actually connected. Lock/magnet: suitable electromagnetic type only.
0 – warning light, 12 V DC; for ELDC max. 200 mA
1 – gate status: output active during movement
2 – electric lock, 3 s pulse
3 – electric strike during opening
4 – magnet active when the gate is closed; release and 3 s delay before opening
5 – lighting during movement and for 1 minute afterward
6 – radio channel 1
7 – radio channel 2
8 – radio channel 3
9 – radio channel 4
Modes 1–9: 24 V DC, max. 10 W. If channel 1–4 is assigned to an output, the motor will not execute its original command.
6 – PHOTOTEST (OUT2)
When testing, observe the TX limit. If you reprogram the output, it will no longer perform the photocell test function.
0 – PHOTOTEST, max. 15 mA
1 – gate status: output active during movement
2 – electric lock, 3 s pulse
3 – electric strike during opening
4 – magnet active when the gate is closed; release and 3 s delay before opening
5 – lighting during movement and for 1 minute afterward
6 – radio channel 1
7 – radio channel 2
8 – radio channel 3
9 – radio channel 4
Modes 1–9: 24 V DC, max. 3 W. After selecting 0, teach the devices again. A channel assigned to an output does not control the motor.
7 – Mechanical stress relief
A brief reverse movement relieves tension after stopping. This is not the lift distance in centimetres. After changing this setting, force learning is required.
0 – off
1 – minimum
2 – intermediate level
3 – factory setting
4 – intermediate level
5 – medium setting
6–8 – higher intermediate levels
9 – maximum
8 – Step-by-step command (SbS)
Changes the sequence for the button and the corresponding radio command.
0 – open → stop → close → open
1 – open → stop → close → stop
2 – shared input: a command during opening will not close the gate; after it is fully open, the next command closes it
3 – semi-automatic opening; closing while the command is held

Set the force only as high as needed for correct movement. A high setting must not be used to compensate for friction or a faulty spring. After setting, check obstacle detection and impact forces.

Remote controls and pairing

The receiver is built in. Compatible remote controls MYGO4, ON2E and INTI2 are paired using the RADIO button. The memory holds 90 entries: in mode 1, one entry for the entire transmitter; in mode 2, one entry per button.

Mode 1 – all buttons

  1. Hold RADIO until the LR LED lights up, then release it.
  2. Within 10 s hold any button on the unidirectional remote control. After LR flashes three times for a longer duration, release the button.
  3. You can save another transmitter during the next 10 s. Press RADIO briefly to end reception.

Button in mode 1Command
1Step-by-step command (SbS)
2Partial opening
3Open
4Close

Mode 2 – one button

Press and release RADIO n times, according to the command number. The LR LED will repeat the number. Within 10 s, save the selected remote-control button as above; repeat the procedure for each additional button.

Number of RADIO pressesCommand
1SbS
2Partial opening 1
3Open
4Close
5Lighting – timer
6Lighting – on/off

LR flashes once for a remote control that is already saved, 6 times for incompatible coding, and 8 times when the memory is full.

Adding a remote control using an existing one

Carry out the procedure within range of the operator and only when learning is enabled. The new remote control will inherit the assignment of the original.

  1. On the new remote control, hold down the desired button for at least 8 s and release.
  2. On the original remote, slowly press and release the stored button three times.
  3. On the new remote, press and release the same button once, as in the first step.

Clearing the radio memory

This deletes all stored remotes. Keep holding RADIO even after the LR LED lights up and then goes out. When it flashes again, release exactly on the third flash. Five long flashes confirm success. Clearing the radio memory is a separate operation from resetting the control unit.

Locking or unlocking the radio memory

  1. Disconnect the mains power and backup power supply. Hold down RADIO and restore the power supply.
  2. After 5 seconds, LR flashes slowly twice. Release RADIO.
  3. Within 5 seconds, use short presses of RADIO to select: LR off = unlocked; LR lit = locked.
  4. Two slow flashes 5 seconds after the last press confirm that the procedure is complete.

When the memory is locked, remotes cannot be paired, copied, or deleted; this does not mechanically lock the gate.

Clearing the memory and restoring settings

Select position 9 – Clear memory. Selecting a value starts the corresponding deletion; it is not merely a tentative selection. Decide what you want to keep before proceeding.

ValueWhat is deleted
0Custom parameters are restored to factory settings; positions and remotes are retained.
1Configuration, learned devices, and positions; remotes are retained.
2Only the remotes in the radio memory.
3All memory contents, including configuration, positions, and remotes.

After deleting the configuration or positions, re-learn the gate and perform a test. After clearing the radio memory, pair the remotes again.

Troubleshooting and fault resolution

The display indicates E1–E8. The corresponding number of short flashes may also be shown by the warning light or interior light; the sequence repeats after a 1-second pause.

IndicatorCause and next step
E1 / 1 flashClosing / position
Position learning is not complete. Perform position learning.
E2 / 2 flashesPhotocells
Remove the obstruction, check the alignment, and photocell wiring. Activation when an obstruction is detected is expected.
E3 / 3 flashesForce limitation
Check manual movement, springs, obstructions, and friction. Do not automatically increase the force; check the mechanics and safety.
E4 / 4 flashesSTOP
Check the STOP safety device.
E5 / 5 flashesParameter memory
Wait at least 30 seconds, then try a command. If the error persists, arrange for servicing.
E6 / 6 flashesOperation limit
Wait a few minutes for the unit to cool down. Check the operating load and the gate resistance.
E7 / 7 flashesInternal electrical circuit
Disconnect all power supplies for a few seconds. If the error persists, have a service technician check the control board and motor wiring.
E8 / 8 flashesContinuous command
Remove the continuously active command, such as a stuck button or relay; check SbS.

LED / indicationMeaning and checks
OK – 1 green flash/sNormal operation; two quick green flashes indicate an input change.
OK offCheck the mains supply and fuses. Before replacing a fuse, identify and eliminate the cause of the fault.
STOP on / offOn = STOP not activated; off = check the STOP device.
Interior light flashesAutomatic force learning has not yet been completed; complete the learning procedure.
Remote lights up, but gate does not respondCheck pairing, coding, and the status of the radio memory.

If a safety device is faulty, do not use the automation system as normal. Safely disengage the gate and arrange a repair. Replace a fuse only with one of the same type and rating; never bypass it.

PS124 backup battery

PS124 is installed in the designated compartment of the drive unit and connected to the specified connector, as described in the installation PDF. Connect it only after completing the mechanical installation, wiring, and programming. The battery remains a source of power even after the mains supply is disconnected: before working, disconnect the mains supply and PS124. The number of operations during a power failure depends on the battery condition, temperature, and gate resistance.

Disengaging the drive and manual operation

Disengage the drive only when the gate is stationary. If a spring is faulty or the gate is unbalanced, the released gate may drop uncontrollably; secure it and call a technician. If the garage can only be accessed through this gate, arrange in advance for an external release suitable for the specific gate.

  1. Pull release cord A. The carriage disengages, and you can safely move the gate by hand.
  2. For a new lock, pull cord A again as shown in the second picture.
  3. Move the gate by hand until the lower and upper parts of the carriage align and engage. Check that it is locked before operating it electrically.

Releasing and re-engaging the SPIDO600 carriage

Maintenance and safe operation

Schedule an inspection no later than every 6 months or after 3,000 cycles, whichever comes first. Disconnect all power sources before maintenance. Check the rail, belt, carriage, brackets, corrosion, springs and gate balance; replace worn parts. After the inspection, repeat the safety device and force tests.

Keep controls out of reach of children. Do not enter the gate area while it is moving. If you hear unusual noise, jerking, or notice that the gate is less well balanced, stop operation and contact service. Take electronic equipment and batteries to an appropriate collection point, not to general waste.

SPIDO600 technical specifications

ParameterValue
ApplicationElectromechanical garage door operator for residential use.
Control unitIntegrated SPA600 with display and PHOTOTEST.
Mains power supply230 V AC ±10%, 50/60 Hz; protective earth conductor.
Motor24 V DC; the complete system is powered from the 230 V AC mains.
Maximum / minimum force600 / 300 N.
Rated / maximum power input150 / 350 W.
Maximum speed0.20 m/s; actual operation depends on the settings and load.
Cycles/day40; also observe the other operating limits.
Continuous operation4 minutes maximum.
Ingress protection / temperatureIP40; −20 to +55 °C.
Head unit dimensions192 × 344 × 90 mm; see drawing for installation details.
Motor weight3.8 kg; this is not the weight of the complete kit.
Auxiliary accessories24 V DC, tolerance −30% / +50%, total max. 100 mA; polarity and terminals.
Backup powerPS124 – optional.
LightingIntegrated LED lighting.

NICE SPIDO600 motor head dimensions

SPIDO600 programming – video

The video supplements the steps above; always check the wiring against the terminals on your control board.

SPIDO600 quick installation pictorial guide (PDF). For complete safety and programming instructions, see the installation manual below.

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about NICE SPIDO600 - standalone operator for garage doors

Product: NICE SPIDO600 - standalone operator for garage doors
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.