Dual-channel (what does that mean?) receiver compatible with NICE rolling-code remote controls of the FloR (the 52-bit code allows 4.5 trillion combinations, making it virtually impossible to misuse). It also recognizes the coding used by O-View remote controls Era One and Era Inti. With this receiver, you can control an automated device of another brand using a NICE remote control. The device includes a BM250 memory module for storing 63 codes.
0. Page contents
1. Product description and electrical wiring
2. Selecting the remote control channel for the relay
3. Using normally closed (NC) contacts
4. Assigning a receiver channel to a remote control button
5. Programming
5.1. QUICK REMOTE CONTROL STORAGE
5.2. STANDARD REMOTE CONTROL STORAGE
5.3. REMOTE CONTROL STORAGE FROM A DISTANCE (WITHIN RECEIVER RANGE)
5.4. ERASING THE ENTIRE MEMORY
5.5. ERASING A SPECIFIC REMOTE CONTROL FROM THE RECEIVER MEMORY
6.1 STEP-BY-STEP
6.2 TIMER
6.3 ALARM
7. Memory lock
7.1 ACTIVATING THE MEMORY LOCK USING HARDWARE
7.2 ACTIVATING THE MEMORY LOCK USING SOFTWARE
7.3 DEACTIVATING THE MEMORY LOCK
7.4 PASSWORD-PROTECTING THE MEMORY
8. Technical specifications of the NICE FloxR FLOX2R receiver
1. Product description and electrical wiring
The external receiver can be mounted on a wall or ceiling using screws, or underneath the cover of the unit, which it is intended to control.
| 1. Open the receiver housing | 2. Connect the electrical wiring according to the following diagram: |
![]() |
![]() |
| Component | Description |
|---|---|
| L1 | Indicator LED |
| P1 | Programming button |
| BM | Removable BM memory module |
| Inputs | Description |
|---|---|
| 1–2 | POWER SUPPLY: 12/24 V DC or AC |
| 3–4 | RELAY 1: normally open (NO) contact for relay 1 |
| 5–6 | RELAY 2: normally open (NO) contact for relay 2 |
| 1–2 | ANTENNA: input for the antenna, ideally use RG58 coaxial cable, as short as possible (up to 10 m). In this case, connect the shield to input 1 and the core of the coaxial cable to input 2. |
2. Selecting the remote control channel for the relay
The external receiver can recognize all four buttons (channels) remote control), but only two buttons (channels) can be used.
Note: NICE remote controls with FloR coding support four types of commands assigned to the individual buttons (channels):
| Button | Command | Sequence when the remote control is pressed repeatedly |
|---|---|---|
| Button 1 | Step-by-step | Open > Stop > Close > Open |
| Button 2 | Partial opening | Partial opening > Stop > Closing > Stop > Partial opening |
| Button 3 | Open only | Open > Stop > Open |
| Button 4 | Close only | Closing > Stop > Closing |
Assigning a channel to each relay is done using a jumper as shown in the following table:
| Channel | Relay 1 | Relay 2 |
|---|---|---|
| Channel 1 | ![]() |
![]() |
| Channel 2 | ![]() |
![]() |
| Channel 3 | ![]() |
![]() |
| Channel 4 | ![]() |
![]() |
3. Using normally closed (NC) contacts
If you need to use an external receiver to control a device that requires normally closed (NC) contacts and performs the specified command when they open, proceed as follows:
- Disconnect the external receiver from the power supply.
- Carefully remove the circuit board from the casing and turn it over.
- As shown in the illustration
break the connection marked X and, using a small drop of solder, join connection Y.


- You do not have to make this change to both relays, so one relay can control normally closed (NC) contacts and the other normally open (NO) contacts
4. Changing the receiver channel assigned to a remote-control button
On the NICE FloR FLO2R-S remote controls you can set directly on the remote control which channel each button transmits. By default, the first button is set to channel 1 and the second button to channel 2. Follow these steps for each button separately:
![]() |
|
![]() |
![]() |
| Break the marked connection and join it to channel 2, 3 or 4 with a drop of solder. | Break the marked connection and join it to channel 1, 3 or 4 with a drop of solder. |
5. Programming
Programming is performed using button P1 and LED L1 on the receiver. The LED indicates the following signals:
| Slow flashing at half-second intervals | |
|---|---|
| Number of flashes | Meaning of the flashes |
| 1 | The code received from the remote control is not authorized, i.e. the remote control/button has not yet been paired. |
| 2 | Recognition of the received code was unsuccessful. If the second flash is longer than the first, the memory lock is enabled. If the flashes are the same length, the memory lock is not enabled. |
| 3 | Recognition of the received code was successful. |
| 4 | The transmitted code is already among the authorized codes. |
| 5 | The code list is empty (no codes are authorized). |
| 6 | The code list is full (there is no room to store another code). |
| 7 | The code you want to delete is not among the authorized codes. |
| 8 | Another code was detected while the code was being recognized (code collision). |
| 9 | A password |
| Rapid quarter-second flashes DURING INITIALIZATION | |
| Number of flashes | Meaning of the flashes |
| 1 | The device contains a BM60 memory module (capacity: 16 codes) |
| 2 | The device contains a BM250 memory module (capacity: 63 codes) |
| 3 | The device contains a BM1000 memory module (capacity: 250 codes) |
| 4 | The memory contains codes that do not use FloR coding |
| 5 | An error was detected while reading the memory |
| Rapid quarter-second flashes DURING OPERATION | |
| Number of flashes | Meaning of the flashes |
| 1 | The received code is a copy; only original codes are valid. |
| 3 | The code is not in the code table but has been resynchronized. |
| 4 | The code is not in the code table and resynchronization is locked. |
| 5 | The code is not in the code table and resynchronization is not possible. |
5.1. Quick remote control programming
Although this is the quickest method, it is not particularly secure, because during programming the receiver may pick up another code within range and accidentally save it. If you are unsure about security, use the standard method.
- Press and hold the P1 button on the receiver; the L1 LED will light up while you continue holding the P1 button
- Continue holding the P1 button and simultaneously press and hold the button on the remote control (the code is being transmitted)
- When the L1 LED goes out, release the button on the remote control (continue holding the P1 button)
- When the L1 LED lights up again, you can program another remote control, see step 2.
- When finished, release the P1 button on the receiver
5.2. Standard remote control programming
- Press and hold the P1 button on the receiver until the L1 LEDlights up, then release the P1 button
- The L1 LED will stay lit for 5 seconds. During this time, press and hold the button on the remote control (the code is being transmitted), until the L1 LED
- goes out. Then release the button on the remote control and wait 1 second
- Press and hold the button on the remote controluntil the L1 LED goes out, then release the button on the remote control
- If programming was successful, the L1 LED will flash three times
If you do not want any more remote controls to be added to the memory, you can lock it.
5.3. Programming a remote control remotely (within range of the receiver)
If you already have an OLD remote control paired with the receiver (i.e. the code transmitted by the remote control is stored in the receiver's memory), you can program a NEW remote control remotely within range of the receiver (10-20m). The OLD remote control must already be programmed and fully functional.
- On the NEW remote control, press and hold the desired button for at least 5 seconds, then release it.
- On the OLD remote control, press the desired button 3 times in succession (at intervals of about one second).
- On the NEW remote control, press the desired button once.
- If pairing was unsuccessful, try pressing the buttons more slowly. Alternatively, in step 1 hold it for 6 seconds.
5.4. Completely erasing the memory
A complete reset also deletes the software memory lock and sets the timer to 3 seconds.
- Press and hold the P1 button on the receiver. The L1 LED will light up and go out after 3 seconds (continue holding the P1 button)
- When the L1 LED starts flashing (continue holding the P1 button), during the third flash, release the P1 button and wait about 3 seconds
- As soon as the LED L1 lights up again, press the P1 button and hold it until the LED L1 goes out
Depending on the type of memory module, the process may take several seconds. During this time, the LED flashes rapidly and then flashes five times slowly to indicate that erasure was successful. If this does not happen, repeat the process.
5.5. Deleting a specific remote control from the receiver's memory
- Press and hold the P1 button on the receiver for approximately 3 seconds, until the LED L1 goes out,, release the P1 button.
- Press and hold the button on the remote control, which you want to delete, until the LED L1 goes out, LED L1, Release the button on the remote control
- Wait 1 second
- Press the button on the remote control again and release it
- LED L1 flashes once to indicate that the remote control has been successfully deleted. If this does not happen, repeat the process.
6. Advanced functions
By default, the relay function is Momentary — when a signal is received from a remote control, its code is recognized and, once successfully identified, the relay switches on (off) for approx. 300 ms.
Advanced functions are activated by soldering the connections according to the diagram:
|
No jumper | all channels Momentary | |
| Jumper 1 | channel 1 Step-by-step channels 2, 3 and 4 Momentary |
||
| Jumper 2 | channels 1 and 2 Step-by-step channels 3 and 4 Momentary |
||
| Jumper 3 | channel 1 Timer channels 2, 3 and 4 Momentary |
||
| Jumper 4 | channels 1+2 Alarm channels 3 and 4 Momentary |
||
| Jumper 5 | all channels Step-by-step |
6.1 Step-by-step
The relay is activated when the button on the remote control is pressed and remains activated after the button is released. Press the button again to deactivate the relay.
6.2 Timer
The relay is activated when a button on the remote control is pressed and remains activated for the programmed time:
- Press and hold button 1 on the remote control (or simply channel 1)
- While holding the button on the remote control for three seconds, also press button P1 on the receiver, then release the button on the remote control
- Hold down button P1 for the desired time to be programmed (up to 150 minutes), then release button P1
- The set time has been saved and will remain saved until the timer is programmed again
Note: The receiver does not respond to other commands while the timer is being programmed. If you do not want the relays to activate while programming the timer, select the channel jumpers.
6.3 Alarm
Coming soon.
7. Locking the memory
If you do not want the memory to be modified, you can lock the memory module.
7.1 Activating the memory lock using hardware
This method is very easy, but not very secure, as an intruder can easily remove the lock.
- Once you are sure that all the required remote controls have been stored, disconnect the receiver from the power supply
- Break connection X on the memory module:

- To add more codes (store remote controls) after locking the memory, place a drop of solder between the two points of connection Y:

7.2 Activating the memory lock using software
This method is more secure because you need a remote control stored in the receiver's memory to deactivate the memory lock:
- Press and immediately release button P1 on the receiver
- Wait until LED L1 flashes twice (after approx. 5 seconds), then press and hold button P1 during the second flash and release it once LED L1 goes out
- The LED will then flash twice. If the second flash lasts longer than the first, the memory lock has been successfully activated. If both flashes are the same, the process was unsuccessful and you must repeat it.
7.3 Deactivating the memory lock
To deactivate the memory lock, you need a remote control that is already stored in the receiver's memory.
- Press the P1 button on the receiver and release it immediately
- The L1 LED then lights up for approx. 5 seconds. During these five seconds, press and hold the button on the remote until the L1 LED goes out, then release it
- Wait 1 second
- Press and hold the button on the remote. The LED will flash 4 times to indicate that the remote is stored in memory and can therefore unlock the memory.
- During the fourth flash, press the P1 button and release it only when L1 goes out
- The LED will then flash twice. If both flashes last the same amount of time, the deletion was successful. If the second flash lasts longer than the first, repeat the process.
7.4 Locking the memory with a password
This method can only be carried out using the BUPC and OBox professional programmers.
8. Technical specifications of the NICE FloxR FLOX2R receiver
| Encoding | FloR O-View (basic functions) |
|---|---|
| Power supply | 12-24V (limit 10-28V) |
| Current consumption (minimum) | 16 mA at 24V |
| Current consumption (maximum) | 80 mA at 24V |
| Frequency | 433,92 MHz |
| Sensitivity | 0,5 µV |
| Number of relays | 2 relays |
| Contact for normally open relay | max. 0,5A and 50V SELV |
| Operating temperature | -20 to +55 °C |
| Protection rating | IP 30 |
| Dimensions | 86×22×58 mm (W×D×H) |
| Weight | 55 g |
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]