KEY Turbo S (TUS8324) - drive for sliding gates up to 800 kg


Product availability: within 3 days

We usually dispatch goods within 3 days.


KEY Turbo S (TUS8324) - drive for sliding gates up to 800 kg KEY Turbo S (TUS8324) - drive for sliding gates up to 800 kg
KEY-TURBO-S800
within 3 days
€278.23 excluding VAT
€342.22 including VAT

 pcs
Weight
12 kg

Description of KEY Turbo S (TUS8324) - drive for sliding gates up to 800 kg

Operator KEY Turbo S (TUS8324) is designed for a sliding gate up to 800 kg. It is equipped with 24 V electric motor, so even intensive operation. The gate leaf reaches a speed of 25 cm per second. The control unit is designated CT-10324 and the operator also includes a so-called electromechanical limit switch — a spring with microswitches. The operator has a built-in receiver for the radio signal.

Installation, wiring and setup
Standalone operatorInstallationWiring
Manual releaseControl boardOverall diagram
Terminals and power supplyPhotocellsSafety inputs
Initial startupTravel learningProgramming
Remote controlsResetDiagnostics
MaintenanceTechnical specificationsSlovak PDF

KEY Turbo S TUS8324 – standalone operator

This is a non-reversible operator for a sliding gate with mechanical limit switches. The accessories shown in the diagrams are examples of wiring and are not a list of items included with the standalone operator.

For installation and mechanical details, refer to the TURBO S manual. The operating procedures below apply to the illustrated CT10324 controller with a five-digit display, UP, MENU, DOWN-RADIO, SBS buttons, and BASE/ADV menus. Before setting up, compare the terminal labels and motor selection on your own board with the illustration shown.

The duty cycle does not allow unlimited continuous operation. A maximum of 40 cycles/hour applies to a reference gate leaf 4 m long, weighing 200 kg, at a temperature of 20 °C. For a longer gate leaf, the number of cycles is reduced proportionally (8 m: by 50%); above 20 °C, reduce it by 15% for every additional 5 °C; for a gate at the maximum permitted weight, reduce it by 50%. Speed depends on the weight of the gate.

TURBO S dimensions: 335 × 190 × 280 mm; pinion position 92 mm
TURBO S dimensions: 335 × 190 × 280 mm; pinion position 92 mm

Mechanical installation of the operator

When released, the gate must move smoothly and must not start moving on its own. It must have sturdy mechanical stops at both the open and closed positions. The gate must travel along a level path, not up or down a slope. The installation location must not be subject to flooding. The manufacturer requires safety edges to protect all potential crushing points (hands, feet and similar); other protective devices and their placement must be determined based on the risks posed by the specific gate.

Manufacturer’s example of a sliding gate system with an operator, photocells, warning light and safety edges
Manufacturer’s example of a sliding gate system with an operator, photocells, warning light and safety edges

Accessories list

  • 2 – operator
  • 3 – photocells
  • 4 – warning light
  • 5 – key switch
  • 6 – remote control
  • 7 – safety edges

The placement of safety devices must be based on the actual risks posed by the specific gate.

Base plate and mounting

Fixing the base plate to the substrate or concrete
Fixing the base plate to the substrate or concrete

  1. Determine the position based on the dimensions of the operator, base plate and rack. Install conduits for the cables. Secure the base plate with sturdy anchor bolts or set it in concrete as shown in the drawing.
  2. Release the operator and open the cover. Place the operator on the base plate and insert the two Allen-head mounting screws. For alternative mounting, use the inner slots in the casting to ensure the mounting does not interfere with the cover.
  3. Level the operator. If rack adjustment is insufficient, use the four levelling screws as shown in figure 4.7. Tighten the two main mounting screws securely; the operator must remain stable throughout the entire travel. Check the mounting again after several operating cycles.

Opening the cover, mounting, levelling and closing the operator again
Opening the cover, mounting, levelling and closing the operator again

Toothed rack and mechanical limit switches

Rack installation: leave a 2 mm gap between the rack and pinion
Rack installation: leave a 2 mm gap between the rack and pinion

  1. With the operator released, open the gate fully. Place the first rack section on the pinion and attach it to the gate using screws and spacers.
  2. Move the gate by hand; align the next sections using a spare piece of rack. After adjustment, maintain a 2 mm gap, so the weight of the gate does not rest on the operator’s pinion.
  3. Set the mechanical limit-switch ramps at the ends of the travel. Depending on the weight of the gate, leave a gap of 30–50 mmbetween the gate and the fixed mechanical stop; the ramp should press the limit switch before the gate hits the stop.
  4. Secure the ramps firmly as shown in the drawing, for both the open and closed positions. The stops must prevent derailment, and their position must prevent the ramp from hitting the toothed wheel.

Adjusting and securing the mechanical limit-switch ramps
Adjusting and securing the mechanical limit-switch ramps

Wiring and separation of power supplies

The power supply for this operator is 230 V AC, 50/60 Hz; the motor operates at 24 V DC. The control board itself is powered by a 24 V AC transformer. Do not mix up mains and low-voltage wiring. The power supply must have protective earthing, suitable overcurrent protection, a residual-current device and a means of disconnection for overvoltage category III. Disconnect the mains supply and any backup power before opening the unit or connecting wires.

Cables specified by the manufacturer for a typical installation
WiringCableMaximum length
230 V power supply3 × 1.5 mm²; for lengths over 20 m: 3 × 2.5 mm²up to 20 m / over 20 m, maximum 50 m
FLASH warning light / LED auxiliary light3 × 0.55 mm²20 m
AntennaRG5810 m; less than 5 m recommended
Electric lock2 × 1.5 mm²10 m
TX photocell2 × 0,55 mm²20 m
RX photocell4 × 0,55 mm²20 m
Safety edge2 × 0,55 mm²20 m
Key switch4 × 0,55 mm²20 m
Motor2 × 1,5 mm²10 m

The cable must be suitable for the installation environment; the manufacturer specifies H03VV-F for indoor use and H05RN-F/H07RN-F for outdoor use. Connect the protective conductor at the control unit.

Manual release in the event of a power failure

  1. The gate must be stationary. Disconnect the power supply and secure the gate against unintended movement.
  2. Insert the release key and turn it 90° counterclockwise.
  3. Flip the release lever out so that it is perpendicular to the drive. You can now move the gate manually.
  4. Re-engage the drive mechanically before resuming motorized operation. Do not engage it while the motor is running; this could damage the internal components.

Key and release lever for the TURBO S drive
Key and release lever for the TURBO S drive

CT10324 control board

Actual CT10324 control board showing connector and control numbers
Actual CT10324 control board showing connector and control numbers

Orientation as shown: heatsink on the left, display and control buttons on the right, main terminal blocks at the bottom. The labels on the board and in the diagrams remain as originally shown. The M1+/M1− designation in the manual's table corresponds to the M+/M− connector shown in the image.

Labels on the board

  • 1 – M+/M−, motor
  • 2 – Transformer power supply
  • 3 – FLASH, IND/ELEC, LED
  • 4 – 24 VAC for accessories
  • 5 – PH-POW and NEG, safety device power supply
  • 6 – Safety inputs
  • 7 – Control inputs
  • 8 – LEDs for safety and control inputs
  • 9 – EDGE, PH2, PH1 DIP switches
  • 10 – Limit switches
  • 11 – Limit switch LEDs
  • 12 – KBP/KBPN, backup battery charger
  • 13 – 1.6 AT fuse, slow-blow
  • 14 – Five-digit display
  • 15 – SBS, step-by-step
  • 16 – UP (+)
  • 17 – MENU
  • 18 – DOWN-RADIO (−)
  • 19 – RADIO / KEY LED
  • 20 – Antenna
  • 21 – Optional SBK energy-saving module
  • 22 – Optional KUBE / PowerBus interface

Overall wiring diagram of the board and accessories

The diagram shows the complete board, transformer and mains supply, ALIGHTEC flashing light, antenna, PH1 TX/RX photocells, and control contacts.

Complete CT10324 manufacturer wiring diagram: power supply, board, flashing light, photocells, antenna, and control inputs
Complete CT10324 manufacturer wiring diagram: power supply, board, flashing light, photocells, antenna, and control inputs

Terminals, polarity, and power supply limits

Power supply and outputs of the control unit shown
TerminalsFunction and wiring
L / N / PEL = live, 230 V AC; N = neutral; PE = protective earth. AC has no +/− polarity.
POWER SUPPLYPower supply to the board from the transformer: 24 V AC (+10% / −15%), 50/60 Hz. Do not connect 230 V here.
M+ / M−Positive (+) and negative (−) terminals of the 24 V DC motor; also labeled M1+/M1− in the diagram.
V+ / ENC / NEG at the motorIn this wiring configuration do not use; these are not the photocell power supply terminals.
24 VAC / 24 VACPair of terminals for accessories: unregulated 24 V AC, 200 mA maximum. No +/− polarity; inactive when running on battery power.
PH-POW / NEGPH-POW = positive (+) pole, NEG = negative (−) pole of the unregulated 24 V DC supply for safety devices; PH-POW limit: 200 mA. The mode is related to PHOTO TEST.
COM at the outputsCommon positive (+) pole for the FLASH, IND/ELEC, and LED outputs.
FLASHFlashing light between COM (+) and switched FLASH (−): 24 V DC, 15 W maximum. The output can be set to steady or flashing mode.
LEDAuxiliary lighting between COM (+) and switched LED (−): unregulated 24 V DC, 15 W maximum.
IND/ELECCommon COM (+), switched IND/ELEC (−). IND mode: indicator light, 24 V DC / 5 W maximum. ELEC mode: electric lock, 12 V DC / 15 VA maximum. The mode is set using INDIC LIGHT.
COM at the inputsCommon point for PH2, PH1, OPEN, CLOSE, PAR, and SBS; positive internally. A control or safety contact is voltage-free; no +/− polarity is specified at its terminals.
LS1 / LS2 / COMLimit switch connector; check the corresponding LEDs.
BATTERIESConnect the KBP/KBPN charger as described in the relevant manual.
ANT / SHIELDANT = signal, the coaxial cable's center conductor; SHIELD = shielding. This is not a +/− power supply pair.

The total current drawn by all devices connected to the relevant power supply output must stay within its limit. Do not confuse the unregulated DC output with 24 V AC. For accessories, use the terminal block terminals specified in the diagram, not NEG/V+/ENC at the motor connector.

PH1 and PH2 photocells – polarity-sensitive wiring

Manufacturer wiring for both PH1 and PH2 photocell pairs; original wires, jumpers, and terminal labels
Manufacturer wiring for both PH1 and PH2 photocell pairs; original wires, jumpers, and terminal labels

Standard DC photocell wiring according to the manufacturer’s diagram
DeviceConnection according to the four-terminal RX shown
TX units for both pairsTX 1 / NEG (−) → board NEG; TX 2 / POS (+) → board PH-POW.
RX units for both pairsRX 1 / NEG (−) → board NEG; RX 2 / POS (+) → COM (+).
PH1 RX contactRX 3 / COM → board COM; RX 4 / OUT (NC) → PH1. The RX 2–3 jumper is shown in the original diagram.
PH2 RX contactRX 3 / COM → board COM; RX 4 / OUT (NC) → PH2. The RX 2–3 jumper is shown in the original diagram.

Numbers 1–4 apply exclusively to the TX/RX shown. Other photocells may have different terminals; connect their power supply and NC contact according to their own instructions. COM and OUT on the receiver are relay contacts, not power supply +/− terminals. When wired according to this diagram, the common contact point is connected to the board’s COM.

PH1 stops and reverses movement during closing; the gate cannot be closed while it is active. PH2 depending on the setting, protects opening or both directions; when interrupted, it stops movement and resumes opening once the beam is clear. FOTO1 SETUP and FOTO2 SETUP change how it behaves.

Photocell test and energy-saving mode

In ADV, set PHOTO TEST: 0 off, 1 PH1, 2 PH2, 3 both pairs. In ADV, set PHOTO TEST: 0 off, 1 PH1, 2 PH2, 3 both pairs. Test only correctly connected devices.

Separate factory wiring diagram for STAND BY energy-saving mode
Separate factory wiring diagram for STAND BY energy-saving mode

In the energy-saving wiring configuration, the positive power leads of both TX and RX connect to PH-POW (+), and the negative leads to NEG (−); the RX contacts remain between COM and PH1/PH2. STAND BY is enabled in BASE. PHOTOTEST is not possible when STAND BY is enabled. Do not combine these two diagrams.

Safety and control inputs

Contacts are voltage-free; do not connect an external voltage to them
InputFunction
EDGE/STOP, pairVoltage-free input for STOP NC or a safety edge; TYPE EDGE: 0 STOP NC, 1 8k2 resistive, 2 NC contact, 3 dual 4k1 resistive. When the safety edge is triggered, movement briefly reverses and stops.
PH1 / COMNC contact of the closing photocell.
PH2 / COMNC contact of the photocell, according to the selected mode.
OPEN / COMNO opening contact.
CLOSE / COMNO closing contact.
SBS / COMNO step-by-step contact, as configured in SBS SETUP.
PAR/EDGE / COMNO partial-opening contact; the STOP TWO parameter allows it to be changed to STOP or a second opening safety edge.

The second safety edge on PAR/EDGE is configured via STOP TWO. For EDGE2, SETUP EDGE must be set to 0 so that the first safety edge, EDGE1, is triggered only during closing. EDGE2 protects during opening and briefly reverses movement when activated. The EDGE DIP switch does not disable this second input.

EDGE, PH2 and PH1 DIP switches on the control board
EDGE, PH2 and PH1 DIP switches on the control board

The ON position disables the corresponding safety function. When safety devices are installed, the corresponding DIP switch must be in the OFF position. An unused input may be disabled only in accordance with the installation’s safety design: set its DIP switch to ON and confirm by holding UP (+) and DOWN-RADIO (−), until the LED for that input stops flashing. This is not a fix for faulty photocells or a faulty safety edge.

Initial startup and motor selection

  1. Check the mechanical mounting, stops, rack, free movement, grounding, and correct wiring of the safety devices. Switch on the power only after completing the wiring.
  2. When the travel has not been learned, LEARN TO DO is displayed. Press UP to cycle through the status, cycle count, motor current, and board type, firmware and serial number; MENU returns to the normal display.
  3. Before learning, select the correct model in ADV → MOTOR SETUP. For KEY Turbo S TUS8324, option 2 is shown in the displayed menu. Select the value according to the model list for the corresponding board; changing the motor type restores the factory parameters and requires the travel to be learned again.

Automatic travel learning

Learning with the standard slowdown range

  1. Disengage the drive, move the gate to approximately halfway along its travel, then re-engage the drive.
  2. Press and hold UP (+) and MENU for approximately two seconds. The gate starts opening slowly; the display shows LEARN OPEN1.
  3. If the gate starts closing instead of opening, stop it with DOWN-RADIO (−). Press SBS to restart learning with the direction reversed.
  4. The motor stops at the opening limit switch. After approximately two seconds, it starts closing; the display shows the closing-learning status.
  5. Learning ends when the gate reaches the closing limit switch. Then run several complete cycles and test all safety devices and forces.

Learning must be completed fully and correctly before handover. According to the manufacturer, it can be interrupted by triggering EDGE, PH2 or PH1, or by disconnecting the power. After successful learning, BASE/ADV parameters can be changed.

Custom slowdown points

In BASE, set LENGH SLOW to P (custom setting) and start learning from halfway along the travel, as described above. Once the gate reaches the open position, the drive starts closing. At the desired slowdown point during closing, press SBS; the display shows CLOS1 SLOW. Once the gate is closed, it starts opening again; at the desired slowdown point during opening, press SBS (OPEN1 SLOW). After reaching the open position, the gate closes one final time. Any point you do not specify is automatically set to 20% of the full travel.

Programming BASE and ADV

  1. Press and hold MENU. When BASE appears, release the button to open the basic menu; to open ADV, hold it for approximately five seconds and release when ADV appears.
  2. Scroll through the items using UP and DOWN-RADIO. The name and value alternate on the display.
  3. To edit, hold MENU until the value starts flashing, then release the button. Change the value using UP/DOWN-RADIO.
  4. Hold MENU until the display stops flashing to save the new value. Exit the menu by briefly pressing MENU.

The tables explain the available options and what they do. Force, speed and safety-function settings must be based on measurements taken on the specific gate. A higher REACT TIME value means lower impact force, not a more powerful motor.

1. AUTO CLOSE

0–900 s; 0 = automatic closing off.

2. PHOTO CLOSE

0–30 s; closing delay after passing through PH1, 0 = off.

3. REACT TIME

0–10; 0 = maximum impact force, 10 = minimum.

4. OPEN SPEED

1–5; opening speed from minimum to maximum.

5. SL-OP SPEED

1–5; opening speed during slowdown.

6. CLOSE SPEED

1–5; closing speed from minimum to maximum.

7. SL-CL SPEED

1–5; closing speed during slowdown.

8. SBS SETUP

0: open–stop–close–stop; 1: open–stop–close–open; 2: open–close; 3: apartment-block mode with timer (AUTO CLOSE ≠ 0); 4: apartment-block mode with immediate closing.

9. STOP TWO

0 = disabled; 1 = PAR as STOP NO; 2 = STOP NC; 3 = NC opening safety edge; 4 = 8k2 opening safety edge; 5 = 4k1 opening safety edge. For EDGE2, SETUP EDGE must be set to 0; the DIP switch does not affect this second input.

10. LENGH SLOW

P = teach-in points; 1–100% of travel for deceleration when opening and closing.

11. BLACK OUT

0 = no action after a power failure; 1 = close.

12. STAND BY

0 = disabled; 1 = energy saving by switching off the photocells when the gate is closed. Requires the appropriate wiring; PHOTOTEST is not available with this function.

1. PHOTO1 SETUP

0 = checks PH1 before opening from the closed position; 1 = opens even if PH1 is activated.

2. PHOTO2 SETUP

0 = PH2 active in both directions; 1 = opening only; 2 = activation switches on the auxiliary light for TIME LIGHT.

3. PHOTO TEST

0 = disabled; 1 = PH1 test; 2 = PH2 test; 3 = test of both pairs.

4. TYPE EDGE

0 = STOP NC; 1 = 8k2 resistive safety edge; 2 = NC contact safety edge; 3 = 4k1 dual resistive safety edge.

5. SETUP EDGE

0 = EDGE1 active when closing; 1 = EDGE1 active when opening and closing. When triggered, it briefly reverses the movement. For a second safety edge on PAR, this must remain set to 0.

6. TEST EDGE

0 = safety-edge test disabled; 1 = enabled.

7. SETUP PART

0–100%; partial opening range.

8. CLOSE PART

0–900 s; closing time from partial-open position, 0 = disabled.

9. FLASH SETUP

0 = steady output; 1 = flashing output.

10. PRE SETUP

0 = pre-flashing before both opening and closing; 1 = before closing; 2 = before opening. Disabled when PRE TIME = 0.

11. PRE TIME

0–20 s; pre-flash time, 0 = disabled.

12. SETUP LIGHT

0 = light stays on for TIME LIGHT after movement ends; 1 = while the gate is not closed, then for TIME LIGHT; 2 = for the set TIME LIGHT duration.

13. TIME LIGHT

0–900 s; auxiliary-light duration.

15. WIND REACT

0 = disabled; 1 = if an attempt is made to open the closed gate, the drive will try to close it again.

16. HOLD TO RUN

0 = standard operation; 1 = movement while the control contact is held.

17. INDIC LIGHT

0 = disabled; 1 = open indicator; 2 = slow flashing while opening, fast flashing while closing, steady light when open, two flashes and a pause when stopped outside the closed position; 3 = electric lock; 4 = magnetic lock with an active output when closed, via an external relay with a 24 V DC coil.

18. CYCLE SERVI

0–200 × 1,000 cycles; service interval, 0 = disabled.

19. SETUP SERVI

0 = disabled; 1 = service reminder indicated by continuous flashing when the gate is closed, if CYCLE SERVI is non-zero.

20. ELECT TIME

1–10 s; electric-lock activation time, or deactivation time for a magnetic lock.

21. BOOST SETUP

0 = disabled; 1 = high-speed startup.

22. ENCOD SETUP

Encoder type display: 0 = virtual, 1 = physical. In the wiring configuration shown in this manual, the V+/ENC/NEG terminals at the motor are not used.

23. MOTOR SETUP

Select the model and restore the factory settings. For the KEY Turbo S TUS8324, use the value 2 in the corresponding motor list on the control unit display; the procedure is described below under Reset.

Remote controls and built-in receiver

The control unit has a 433.92 MHz OOK receiver with a memory capacity of 150 transmitters. To access RADIO, hold DOWN-RADIO for about two seconds. Exit the menu by briefly pressing MENU, or it will close after seven seconds of inactivity. Program the remote close to the control board; if you disconnect the antenna wire to reduce interference, reconnect it when finished.

Saving a remote-control button

  1. Exit any other menu and hold DOWN-RADIO until RADIO MENU appears.
  2. Briefly press DOWN-RADIO to select a function according to the number of presses shown in the table. The KEY LED flashes the corresponding number of times, with a pause of about one second.
  3. Within seven seconds, hold the desired remote-control button near the control board for a few seconds. For LEARN ALL, any button can be pressed.
  4. A long flash of the KEY LED, lasting about three seconds, confirms that the button has been saved. A series of short flashes means the button is already in the memory. Within the next seven seconds, you can save the same function to another button.

Selecting a function when programming a remote
PressesFunction
1LEARN SBS – step-by-step
2LEARN PAR – partial opening
3LEARN OPEN – opening only
4LEARN LIGHT – switch the light on/off
5LEARN ALL – buttons 1 SBS, 2 partial opening, 3 opening only, 4 light

The light switched on by remote control is switched off by remote control.

Deleting a saved button

  1. Enter RADIO MENU.
  2. Hold DOWN-RADIO until the KEY LED lights up, then release the button.
  3. Within seven seconds, hold the remote-control button to be deleted until the KEY LED starts flashing, then release it.
  4. Confirm deletion by pressing DOWN-RADIO. A long flash of the KEY LED confirms deletion.

If the remote was saved using LEARN ALL, this procedure deletes all functions assigned to it.

Deleting all remote-control memory

  1. In RADIO MENU, hold DOWN-RADIO: the KEY LED lights up after about three seconds; keep holding until it goes out, then release the button.
  2. The LED starts flashing slowly. On the third flash briefly press DOWN-RADIO.
  3. A long flash of the KEY LED confirms that all remotes have been deleted.

Adding a new remote using one already saved

  1. Near the control unit, hold a button on the new remote for at least five seconds.
  2. On the remote control already stored in the system, hold the button for the required function for at least three seconds. If the first step was performed correctly, the gate will not move during this step.
  3. Hold the same button on the new remote control again for at least three seconds.
  4. Hold the same button on the old remote control again for at least three seconds. Successful storage is confirmed when the copied command is executed.

Restoring factory settings

Resetting settings via MOTOR SETUP and deleting remote controls are separate procedures. If the motor type is not changed, the manual specifies restoring the factory settings without having to relearn the travel distance. If you change the type, the travel distance must be learned again.

  1. Hold MENU until ADV appears. Use UP/DOWN-RADIO to select MOTOR SETUP.
  2. Hold MENU until the motor type number starts flashing.
  3. Select value 2 for KEY Turbo S TUS8324 according to the corresponding list of board motors.
  4. Hold MENU during the countdown 50 → 0. Release when DONE appears. Exit the menu by briefly pressing MENU or after seven seconds of inactivity.

Display, input and beacon diagnostics

First, remove the cause. The error message will then clear after a full movement to the relevant limit switch, or by briefly pressing MENU without moving the gate. Only work on the mechanism and terminal blocks after disconnecting the power supply.

Operating and error messages
MessageMeaning / check
LEARN TO DOTravel distance has not been learned.
READYGate closed; control unit restarted.
OPEN ING / CLOSE INGOpening / closing in progress.
STOP OPEN / STOP CLOSEMovement stopped while opening / closing.
FOTO1 / FOTO2PH1 / PH2 input active; check the photocells, any obstruction and the wiring.
ALIGN MENTPosition recovery in progress.
OPENGate open with no active closing timer.
PAR TIAL / PART OPENPartial opening / stopped in a partially open position.
TIME CLOSE / TIME PARTClosing timer from fully / partially open position; the remaining time is displayed during the last ten seconds.
LEARN STOPLearning stopped by a safety device or an intentional stop command.
LEARN OPEN1 / LEARN CLOS1Learning the opening / closing travel distance.
SLOW OPEN1 / SLOW CLOS1Determining the deceleration points automatically.
OVER LOAD1Motor current rose sharply; check for an obstruction and mechanical resistance.
EDGESafety edge active or incorrectly wired.
FOTO TESTPhotocell or safety edge test failed; check operation and wiring.

Signalling according to the manufacturer's instructions
Beacon / LED KEY flashingEvent
2 quick flashes + pause + 1Automatic learning
4 quick flashes + pause, three timesObstruction detected
2 quick flashes + pause, three timesPH1/PH2 photocell triggered
5 quick flashes + pause, three timesSafety edge triggered
3 quick flashes + pause, three timesPhotocell or safety edge test failed
6 quick flashes + pause, three timesShort circuit or overload on the FLASH, IND/ELEC or LED output

Press UP repeatedly to display the number of full cycles (NCY), the motor's instantaneous current in mA, and the board type/firmware version/serial number. Red LEDs are for safety inputs and limit switches; green LEDs are for control inputs. A flashing LED after switching the safety DIP requires the relevant confirmation; do not disable functioning safety devices as a way to resolve a fault.

Checks and maintenance

Before handover, test all components, photocells, safety edges, commands, stops and manual release, and measure the impact forces. Provide the manual, safety instructions, documentation and maintenance schedule. For normal domestic use, the manufacturer recommends an inspection every six months; adjust the interval according to usage.

When the system is safely shut down and released, the user may clean the photocell lenses with a slightly damp cloth and remove leaves or stones. Carry out functional and safety tests after repairs or changes to the settings. In the event of a fault, disconnect the power supply and call a service technician; faulty safety devices must be repaired without delay. Keep the key and remote controls out of children's reach.

Technical specifications of KEY Turbo S TUS8324

Specifications of the standalone drive
ParameterValue
Brand:KEY Automation
Model:Turbo S (TUS8324)
Control unit:CT-10324
Drive power supply:230 V
Motor power supply:24V
Limit stop:electromechanical switch
Power consumption:345 W
Motor current:1,5 A
Gear module:M4
Max. load:800 kg
Speed:25 cm/s
Protection rating:IP44
Operating temperature:-20 / +55 °C
Torque26 Nm
Dimensions (L × W × H)335 × 190 × 280 mm
Drive weight8,5 kg
Maximum cycles per hour40 under the reference conditions listed above
Noise≤ 70 dB(A)
Integrated receiver433,92 MHz OOK; 150 transmitters

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about KEY Turbo S (TUS8324) - drive for sliding gates up to 800 kg

Product: KEY Turbo S (TUS8324) - drive for sliding gates up to 800 kg
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.