KEY Turbo S (TUS6324) - sliding gate operator for gates up to 600 kg


Product availability: within 3 days

We usually dispatch goods within 3 days.


KEY Turbo S (TUS6324) - sliding gate operator for gates up to 600 kg KEY Turbo S (TUS6324) - sliding gate operator for gates up to 600 kg
KEY-TURBO-S600
within 3 days
€232.56 excluding VAT
€286.05 including VAT

 pcs
Weight
10 kg

Description of KEY Turbo S (TUS6324) - sliding gate operator for gates up to 600 kg

Drive KEY Turbo S (TUS6324) is designed for a sliding gate up to 600 kg. It is equipped with a 24 V electric motor, so even heavy use. The gate leaf reaches a speed of 24 cm per second. The control unit is designated CT-10324 and the drive also includes a so-called electromechanical limit switch — a spring with microswitches. The drive has a built-in receiver for the radio signal.

Installation, wiring and setup
Standalone driveInstallationWiring
Manual releaseControl boardOverall diagram
Terminals and power supplyPhotocellsSafety inputs
Initial startupLearning the travel limitsProgramming
Remote controlsResetDiagnostics
MaintenanceTechnical specificationsSlovak PDF

KEY Turbo S TUS6324 – standalone drive

This is a non-reversible drive for a sliding gate with mechanical limit switches. Accessories shown in the diagrams are examples of wiring; they are not a list of items included with the standalone drive.

For installation and mechanical components, refer to the TURBO S manual. The operating procedures below apply to the CT10324 control unit shown, with a five-digit display, UP, MENU, DOWN-RADIO and SBS buttons, and BASE/ADV menus. Before configuring the unit, compare the terminal labels and motor selection on your own board with the illustration shown.

The duty cycle does not allow unlimited continuous operation. A maximum of 40 cycles/hour applies to a reference gate leaf 4 m long, weighing 200 kg, at a temperature of 20 °C. For a longer gate leaf, reduce the number proportionally (8 m: by 50%); above 20 °C, reduce it by 15% for every additional 5 °C; for a gate at the maximum permitted weight, reduce it by 50%. Speed depends on the weight of the gate.

TURBO S dimensions: 335 × 190 × 280 mm; pinion position: 92 mm
TURBO S dimensions: 335 × 190 × 280 mm; pinion position: 92 mm

Mechanical installation of the drive

When released, the gate must move smoothly, must not start moving on its own, and must have solid mechanical stops in both the open and closed positions. It must have solid mechanical stops in both the open and closed positions. The gate must travel along a level track, not up or down a slope. The installation site must not be subject to flooding. The manufacturer requires safety edges to protect all potential crushing points (hands, feet, etc.); other protective devices and their positioning must be determined according to the risks presented by the specific gate.

Manufacturer's example of a sliding gate installation with a drive, photocells, warning light and safety edges
Manufacturer's example of a sliding gate installation with a drive, photocells, warning light and safety edges

The installation diagram shows the drive (2), photocells (3), warning light (4), key switch (5), controller (6) and safety edges (7). Safety devices must be positioned according to the actual risks presented by the specific gate.

Foundation plate and fastening

Fastening the foundation plate to the base or concrete
Fastening the foundation plate to the base or concrete
  1. Determine the position based on the dimensions of the drive, foundation plate and rack. Prepare conduits for the cables. Secure the foundation plate to the base with strong anchor bolts, or set it in concrete as shown in the drawing.
  2. Release the drive and open the cover. Place the drive on the foundation plate and insert the two hex socket-head fixing screws. For an alternative fixing method, use the internal slots in the casting to prevent the fasteners from interfering with the cover.
  3. Level the drive. If rack adjustment is insufficient, use the four levelling screws as shown in figure 4.7. Tighten the two main fixing screws securely; the drive must remain stable throughout its travel. Recheck the fixing after several movements.
Opening the cover, fastening, levelling and closing the drive again
Opening the cover, fastening, levelling and closing the drive again

Toothed rack and mechanical limit switches

Installing the rack: leave a 2 mm gap between the rack and pinion
Installing the rack: leave a 2 mm gap between the rack and pinion
  1. With the drive released, open the gate fully. Place the first rack section on the pinion and secure it to the gate using screws and spacers.
  2. Move the gate by hand and align the next sections using a spare piece of rack. After adjustment, maintain a 2 mm gap, so the weight of the gate does not rest on the drive pinion.
  3. Set the mechanical limit-switch cams at the ends of the travel path. Depending on the weight of the gate, leave a gap between the gate and the fixed mechanical stop of 30–50 mm; the cam should activate the limit switch before the gate hits the stop.
  4. Secure the cams firmly as shown in the drawing, in both the open and closed positions. The stops must prevent derailment, and must be positioned so that the cam cannot hit the gear wheel.
Adjusting and securing the mechanical limit-switch cams
Adjusting and securing the mechanical limit-switch cams

Wiring and separation of power supplies

The power supply for this drive is 230 V AC, 50/60 Hz; the motor operates at 24 V DC. The control board itself is powered by a 24 V AC transformer. Do not mix up mains and low-voltage wiring. The power supply must have protective earthing, suitable overcurrent protection, a residual-current device and a disconnecting device for overvoltage category III. Disconnect the mains supply and any backup power before opening the unit or wiring it.

Cables specified by the manufacturer for a typical installation
ConnectionCableMaximum length
230 V supply3 × 1.5 mm²; for lengths over 20 m: 3 × 2.5 mm²up to 20 m / over 20 m, maximum 50 m
FLASH warning light / LED courtesy light3 × 0.55 mm²20 m
AntennaRG5810 m; less than 5 m recommended
Electric lock2 × 1.5 mm²10 m
Photocell TX2 × 0.55 mm²20 m
Photocell RX4 × 0.55 mm²20 m
Safety edge2 × 0.55 mm²20 m
Key switch4 × 0.55 mm²20 m
Motor2 × 1.5 mm²10 m

The cable must be suitable for the installation environment; the manufacturer specifies H03VV-F for indoor use and H05RN-F/H07RN-F for outdoor use. Connect the protective conductor at the control unit.

Manual release in the event of a power failure

  1. The gate must be stationary. Disconnect the power supply and secure the gate against unintended movement.
  2. Insert the release key and turn it 90° counterclockwise.
  3. Flip the release lever out so that it is perpendicular to the drive. You can now move the gate manually.
  4. Mechanically re-engage the drive before operating it under power again. Do not re-engage it while the motor is running; this could damage internal components.
Key and release lever for the TURBO S drive
Key and release lever for the TURBO S drive

CT10324 control board

Actual CT10324 control board with connector and control labels
Actual CT10324 control board with connector and control labels

Orientation as shown: heatsink on the left, display and control buttons on the right, main terminal blocks at the bottom. The labels on the board and in the diagrams remain unchanged. The M1+/M1− designation in the instruction manual's table corresponds to the M+/M− connector shown in the image.

Board legend according to the manufacturer's diagram
NumberComponent
1M+/M−, motor
2Power supply from transformer
3FLASH, IND/ELEC, LED
424 VAC for accessories
5PH-POW and NEG, safety device power supply
6Safety inputs
7Control inputs
8Safety and control input LEDs
9EDGE, PH2, PH1 DIP switches
10Limit switches
11Limit switch LEDs
12KBP/KBPN, backup battery charger
131.6 AT fuse, slow-blow
14Five-digit display
15SBS, step-by-step
16UP (+)
17MENU
18DOWN-RADIO (−)
19LED RADIO / KEY
20Antenna
21Optional SBK energy-saving module
22Optional KUBE / PowerBus interface

Overall wiring diagram for the board and accessories

The diagram shows the complete board, transformer and mains supply, ALIGHTEC warning light, antenna, PH1 TX/RX photocells and control contacts.

Complete CT10324 manufacturer’s wiring diagram: power supply, board, warning light, photocells, antenna and control inputs
Complete CT10324 manufacturer’s wiring diagram: power supply, board, warning light, photocells, antenna and control inputs

Terminals, polarity and power supply limits

Power supply and outputs of the control unit shown
TerminalsFunction and wiring
L / N / PEL = live 230 V AC; N = neutral; PE = protective earth. AC has no +/− polarity.
POWER SUPPLYPower supply to the board from the transformer: 24 V AC (+10% / −15%), 50/60 Hz. Do not connect 230 V here.
M+ / M−Positive (+) and negative (−) terminals of the 24 V DC motor; also labeled M1+/M1− in the diagram.
V+ / ENC / NEG at the motorIn this wiring configuration do not use; this is not a photocell power supply.
24 VAC / 24 VACPair for accessories: unregulated 24 V AC, maximum 200 mA. No +/− polarity; inactive when running on battery power.
PH-POW / NEGPH-POW = positive (+) pole, NEG = negative (−) pole of the unregulated 24 V DC supply for safety devices; PH-POW is limited to 200 mA. The mode is associated with PHOTO TEST.
COM at the outputsCommon positive (+) pole for the FLASH, IND/ELEC and LED outputs.
FLASHWarning light connected between COM (+) and switched FLASH (−): 24 V DC, maximum 15 W. The output can be set to steady or flashing mode.
LEDAuxiliary lighting connected between COM (+) and switched LED (−): unregulated 24 V DC, maximum 15 W.
IND/ELECCommon COM (+), switched IND/ELEC (−). IND mode: indicator light, 24 V DC / maximum 5 W. ELEC mode: electric lock, 12 V DC / maximum 15 VA. Mode is set by INDIC LIGHT.
COM at the inputsCommon point for PH2, PH1, OPEN, CLOSE, PAR and SBS; internally positive. A control or safety contact is volt-free; no +/− polarity is specified at its terminals.
LS1 / LS2 / COMLimit switch connector; check the corresponding LEDs.
BATTERIESConnect the KBP/KBPN charger according to the relevant instructions.
ANT / SHIELDANT = signal, coaxial cable center conductor; SHIELD = shielding. This is not a +/− power supply pair.

The total current draw of all devices on the relevant power supply output must remain within its limit. Do not confuse the unregulated DC output with 24 V AC. For accessories, use the terminal block terminals shown in the wiring diagram, not NEG/V+/ENC at the motor connector.

PH1 and PH2 photocells – polarity-sensitive wiring

Factory wiring for both pairs of PH1 and PH2 photocells; original wires, jumpers, and terminal labels
Factory wiring for both pairs of PH1 and PH2 photocells; original wires, jumpers, and terminal labels

Standard DC photocell wiring as shown in the factory diagram
DeviceConnection for the four-terminal RX shown
TX units for both pairsTX 1 / NEG (−) → board NEG; TX 2 / POS (+) → board PH-POW.
RX units for both pairsRX 1 / NEG (−) → board NEG; RX 2 / POS (+) → COM (+).
PH1 RX contactRX 3 / COM → board COM; RX 4 / OUT (NC) → PH1. The RX 2–3 jumper is shown in the original diagram.
PH2 RX contactRX 3 / COM → board COM; RX 4 / OUT (NC) → PH2. The RX 2–3 jumper is shown in the original diagram.

Numbers 1–4 apply only to the TX/RX units shown. Other photocells may have different terminals; connect their power supply and NC contact according to their own instructions. COM and OUT on the receiver are relay contacts, not power-supply +/− terminals. When wired according to this diagram, the contact common is connected to the board COM terminal.

PH1 stops and reverses movement while closing; while it is active, the gate cannot be closed. PH2 depending on the setting, protects opening or both directions; when the circuit opens, it stops movement and resumes opening once released. FOTO1 SETUP and FOTO2 SETUP change how it operates.

Photocell testing and energy-saving mode

During photocell testing, TX power is controlled via PH-POW. In ADV, set PHOTO TEST: 0 off, 1 PH1, 2 PH2, 3 both pairs. Test only correctly connected devices.

Separate factory wiring diagram for STAND BY energy-saving mode
Separate factory wiring diagram for STAND BY energy-saving mode

In the energy-saving wiring, the positive power terminals of both TX and RX are connected to PH-POW (+), and the negative terminals to NEG (−); RX contacts remain connected between COM and PH1/PH2. STAND BY is enabled in BASE. PHOTOTEST is not available when STAND BY is enabled. Do not combine these two diagrams.

Safety and control inputs

Contacts are volt-free; do not connect an external voltage to them
InputFunction
EDGE/STOP, pairVolt-free STOP NC or safety-edge input; TYPE EDGE: 0 STOP NC, 1 8k2 resistive, 2 NC contact, 3 dual 4k1 resistive. When the safety edge is triggered, movement briefly reverses and then stops.
PH1 / COMNC contact of the closing photocell.
PH2 / COMNC contact of the photocell, depending on the selected mode.
OPEN / COMNO opening contact.
CLOSE / COMNO closing contact.
SBS / COMNO step-by-step contact, as set by SBS SETUP.
PAR/EDGE / COMNO partial-opening contact; the STOP TWO parameter allows it to be changed to STOP or a second opening safety edge.

Set the second safety edge on PAR/EDGE using STOP TWO. For EDGE2, SETUP EDGE must be set to 0 so that the first safety edge, EDGE1, is triggered only while closing. EDGE2 protects opening and briefly reverses movement when activated. The EDGE DIP switch does not disable this second input.

EDGE, PH2, and PH1 DIP switches on the control board
EDGE, PH2, and PH1 DIP switches on the control board

The ON position disables the corresponding safety function. When safety devices are in use, the corresponding DIP switch must be set to OFF. An unused input may be disabled only in accordance with the installation's safety design: set its DIP switch to ON and confirm by pressing and holding UP (+) and DOWN-RADIO (−), until the LED for that input stops flashing. This is not a fix for faulty photocells or a faulty safety edge.

Initial startup and motor selection

  1. Check the mechanical fastenings, end stops, rack, free movement, grounding, and correct wiring of safety devices. Switch on the power only after completing the wiring.
  2. When the travel limits have not been learned, LEARN TO DO is displayed. Press UP to scroll through the status, cycle count, motor current, board type, firmware, and serial number; press MENU to return to the normal display.
  3. Before learning, set the correct model in ADV → MOTOR SETUP. For KEY Turbo S TUS6324, the displayed menu option is 8. Select the value according to the model list for the board; changing the motor type restores factory settings and requires the travel limits to be learned again.

Automatic travel learning

Learning with the standard deceleration range

  1. Release the drive, move the gate to approximately halfway along its travel, then re-engage the drive.
  2. Press and hold UP (+) and MENU for approximately two seconds. The gate starts opening slowly; the display shows LEARN OPEN1.
  3. If the gate starts closing instead of opening, stop it with DOWN-RADIO (−). Use the SBS button to restart learning with the direction reversed.
  4. The motor stops at the opening limit switch. After approximately two seconds, it starts closing and the display shows the closing-learning status.
  5. Learning ends when the closing limit switch is reached. Then run several complete cycles and test all safety devices and forces.

Learning must be completed fully and correctly before handover. According to the manufacturer, learning is interrupted by triggering EDGE, PH2, or PH1, or by disconnecting the power supply. After successful learning, BASE/ADV parameters can be changed.

Custom deceleration points

In BASE, set LENGH SLOW to P (custom setting) and start learning from halfway along the travel, as described above. Once the open position is reached, the drive starts closing. At the desired deceleration point while closing, press SBS; the display shows CLOS1 SLOW. After closing, it starts opening again; at the deceleration point while opening, press SBS (OPEN1 SLOW). Once the open position is reached, the final closing cycle follows. If a point is not entered, it is automatically set to 20% of the total travel.

Programming BASE and ADV

  1. Press and hold MENU. When BASE appears, release the button to open the basic menu; to access ADV, hold for approximately five seconds and release when ADV appears.
  2. Scroll through the items using UP and DOWN-RADIO. The name and value alternate on the display.
  3. To edit, hold MENU until the value starts flashing, then release the button. Change the value using UP/DOWN-RADIO.
  4. Hold MENU until the display stops flashing to save the new value. Briefly press MENU to exit the menu.

The tables explain the functions and available options. Force, speed, and safety-function settings must be based on measurements taken on the specific gate. A higher REACT TIME value means lower impact force, not a more powerful motor.

1. AUTO CLOSE

0–900 s; 0 = automatic closing off.

2. PHOTO CLOSE

0–30 s; closing time after passing through PH1, 0 = off.

3. REACT TIME

0–10; 0 = maximum impact force, 10 = minimum.

4. OPEN SPEED

1–5; opening speed from minimum to maximum.

5. SL-OP SPEED

1–5; opening speed during deceleration.

6. CLOSE SPEED

1–5; closing speed from minimum to maximum.

7. SL-CL SPEED

1–5; closing speed during deceleration.

8. SBS SETUP

0: open–stop–close–stop; 1: open–stop–close–open; 2: open–close; 3: apartment-block mode with timer (AUTO CLOSE ≠ 0); 4: apartment-block mode with immediate closing.

9. STOP TWO

0 = disabled; 1 = PAR as STOP NO; 2 = STOP NC; 3 = opening safety edge NC; 4 = opening safety edge 8k2; 5 = opening safety edge 4k1. For EDGE2, SETUP EDGE must be 0; DIP does not affect this second input.

10. LENGH SLOW

P = custom points set by learning; 1–100% of travel for deceleration during opening and closing.

11. BLACK OUT

0 = no action after a power failure; 1 = closing.

12. STAND BY

0 = off; 1 = energy saving by switching off the photocells when the gate is closed. Requires the appropriate wiring; PHOTOTEST is not available with this function.

1. FOTO1 SETUP

0 = checks PH1 before opening from the closed position; 1 = opens even when PH1 is activated.

2. FOTO2 SETUP

0 = PH2 active in both directions; 1 = opening only; 2 = activation switches on the auxiliary light for TIME LIGHT.

3. PHOTO TEST

0 = off; 1 = PH1 test; 2 = PH2 test; 3 = test of both pairs.

4. TYPE EDGE

0 = STOP NC; 1 = 8k2 resistive safety edge; 2 = NC contact safety edge; 3 = 4k1 dual resistive safety edge.

5. SETUP EDGE

0 = EDGE1 active during closing; 1 = EDGE1 active during both opening and closing. When triggered, it briefly reverses movement. For a second safety edge connected to PAR, this must remain set to 0.

6. TEST EDGE

0 = safety edge test off; 1 = on.

7. SETUP PART

0–100%; partial opening range.

8. CLOSE PART

0–900 s; closing time from partial opening, 0 = off.

9. FLASH SETUP

0 = steady output; 1 = flashing.

10. PRE SETUP

0 = pre-flashing before both opening and closing; 1 = before closing; 2 = before opening. Disabled when PRE TIME = 0.

11. PRE TIME

0–20 s; pre-flashing duration, 0 = off.

12. SETUP LIGHT

0 = light stays on after movement ends for TIME LIGHT; 1 = while the gate is open, then for TIME LIGHT; 2 = for the set TIME LIGHT duration.

13. TIME LIGHT

0–900 s; auxiliary lighting duration.

15. WIND REACT

0 = off; 1 = when an attempt is made to open a closed gate, the drive will attempt to close it again.

16. HOLD TO RUN

0 = normal operation; 1 = movement occurs while the control contact is held.

17. INDIC LIGHT

0 = off; 1 = open indicator; 2 = slow flashing during opening, fast flashing during closing, steady light when open, two flashes and a pause when stopped outside the closed position; 3 = electric lock; 4 = magnetic lock with an active output when closed, via an external relay with a 24 V DC coil.

18. CYCLE SERVI

0–200 × 1,000 cycles; service interval, 0 = disabled.

19. SETUP SERVI

0 = off; 1 = service reminder indicated by continuous flashing when the gate is closed, if CYCLE SERVI is non-zero.

20. ELECT TIME

1–10 s; electric lock activation time, or deactivation time for a magnetic lock.

21. BOOST SETUP

0 = off; 1 = high-speed start.

22. ENCOD SETUP

Encoder type display: 0 = virtual, 1 = physical. In the wiring shown in this manual, the V+/ENC/NEG terminals at the motor are not used.

23. MOTOR SETUP

Select the model and restore factory settings. For KEY Turbo S TUS6324, use the value 8 in the corresponding motor list on the displayed controller; the procedure is below in the Reset section.

Remote controls and built-in receiver

The controller has a 433.92 MHz OOK receiver with a memory capacity of 150 transmitters. Enter RADIO by holding DOWN-RADIO for about two seconds. Exit the menu by briefly pressing MENU, or it will close after seven seconds of inactivity. Perform the learning procedure near the control board; if you disconnect the antenna wire to reduce interference, reconnect it afterwards.

Saving a remote-control button

  1. Exit any other menu and hold DOWN-RADIO until RADIO MENU appears.
  2. Briefly press DOWN-RADIO to select a function according to the number of presses shown in the table. The KEY LED flashes the corresponding number of times, with a pause of about one second.
  3. Within seven seconds, hold the desired remote-control button for a few seconds near the control board. For LEARN ALL, any button can be pressed.
  4. A long flash from the KEY LED for about three seconds confirms that it has been saved. A series of short flashes means that the button is already in memory. The same function can be saved to another button within the next seven seconds.

Selecting a function when programming the radio
CountFunction
1LEARN SBS – step-by-step
2LEARN PAR – partial opening
3LEARN OPEN – opening only
4LEARN LIGHT – switch lighting on/off
5LEARN ALL – buttons 1 SBS, 2 partial, 3 open only, 4 lighting

The light switched on by the remote control is switched off by the remote control.

Deleting a stored button

  1. Enter RADIO MENU.
  2. Hold DOWN-RADIO until LED KEY lights up; then release the button.
  3. Within seven seconds, hold the remote-control button to be deleted until LED KEY starts flashing; release it.
  4. Confirm deletion with DOWN-RADIO. A long flash of LED KEY confirms deletion.

If the remote control was stored using LEARN ALL, this procedure deletes all functions assigned to it.

Deleting all remote controls from memory

  1. In RADIO MENU, hold DOWN-RADIO: LED KEY lights up after about three seconds; keep holding until it goes out, then release the button.
  2. The LED starts flashing slowly. At the third flash, briefly press DOWN-RADIO.
  3. A long flash of LED KEY confirms that all remote controls have been deleted.

Adding a new remote control using one that is already stored

  1. Near the control unit, hold the button on the new remote control for at least five seconds.
  2. On the remote control that is already stored, hold the button for the desired function for at least three seconds. After the first step is completed correctly, the gate will not move during this step.
  3. Again, hold the same button on the new remote control for at least three seconds.
  4. Again, hold the same button on the old remote control for at least three seconds. Successful storage is confirmed when the copied command is carried out.

Restoring factory settings

Resetting settings via MOTOR SETUP and deleting remote controls are separate procedures. If the motor type is not changed, the manual specifies restoring the factory settings without needing to learn the travel path again. If you change the type, the travel path must be learned again.

  1. Hold MENU until ADV appears. Use UP/DOWN-RADIO to select MOTOR SETUP.
  2. Hold MENU until the motor type number starts flashing.
  3. Select value 8 for KEY Turbo S TUS6324 according to the corresponding motor list for the control board.
  4. Hold MENU during the countdown 50 → 0. Release when DONE appears. Exit the menu by briefly pressing MENU or after seven seconds of inactivity.

Display, input and warning light diagnostics

First, eliminate the cause. The error message will then clear once the gate has moved fully to the relevant limit switch, or when you briefly press MENU without moving the gate. Only work on the mechanism and terminal blocks after disconnecting the power supply.

Operating and error messages
MessageMeaning / check
LEARN TO DOThe travel path has not been learned.
READYGate closed, control unit restarted.
OPEN ING / CLOSE INGOpening / closing in progress.
STOP OPEN / STOP CLOSEMovement was stopped while opening / closing.
FOTO1 / FOTO2PH1 / PH2 input active; check the photocells, any obstruction and the wiring.
ALIGN MENTPosition recovery in progress.
OPENGate open with no active closing timer.
PAR TIAL / PART OPENPartial opening / stopped in the partially open position.
TIME CLOSE / TIME PARTClosing timer from fully / partially open; the remaining time is displayed during the last ten seconds.
LEARN STOPLearning stopped by a safety device or an intentional stop command.
LEARN OPEN1 / LEARN CLOS1Learning the opening / closing travel path.
SLOW OPEN1 / SLOW CLOS1Determining the slowdown points automatically.
OVER LOAD1Motor current has risen sharply; check for an obstruction and mechanical resistance.
EDGESafety edge active or incorrectly wired.
FOTO TESTPhotocell or safety edge test failed; check operation and wiring.

Signals according to the manufacturer's manual
Warning light / LED KEY flashingEvent
2 quick flashes + pause + 1Automatic learning
4 quick flashes + pause, three timesObstruction detected
2 quick flashes + pause, three timesPH1/PH2 photocell triggered
5 quick flashes + pause, three timesSafety edge triggered
3 quick flashes + pause, three timesPhotocell or safety edge test failed
6 quick flashes + pause, three timesShort circuit or overload on the FLASH, IND/ELEC or LED output

Repeatedly press UP to display the total number of cycles (NCY), the instantaneous motor current in mA, and the control board type/firmware version/serial number. Red LEDs indicate safety inputs and limit switches; green LEDs indicate control inputs. A flashing LED after changing a safety DIP switch requires the relevant confirmation; do not disable functioning safety devices as a way to resolve a fault.

Checks and maintenance

Before handover, test all components, photocells, safety edges, commands, stops and manual release, and measure impact forces. Provide the manual, safety instructions, documentation and maintenance plan. For normal domestic use, the manufacturer recommends an inspection every six months; adjust the interval to suit usage.

With the system safely shut down and disengaged, the user may clean the photocell lenses with a slightly damp cloth and remove leaves or stones. Carry out functional and safety tests after repairs or changes to the settings. In the event of a fault, disconnect the power supply and call a service technician; faulty safety devices must be repaired immediately. Keep the key and remote controls out of children's reach.

Technical specifications of KEY Turbo S TUS6324

Specifications of the standalone drive
ParameterValue
Brand:KEY Automation
Model:Turbo S (TUS6324)
Control unit:CT-10324
Drive power supply:230 V
Motor power supply:24V
Limit stop:electromechanical switch
Power consumption:250 W
Motor current:1.2 A
Pinion module:M4
Max. load:600 kg
Speed:24 cm/s
Protection rating:IP44
Operating temperature:-20 / +55 °C
Torque18 Nm
Dimensions (L × W × H)335 × 190 × 280 mm
Drive weight8 kg
Maximum cycles/h40 under the reference conditions specified above
Noise≤ 70 dB(A)
Integrated receiver433.92 MHz OOK; 150 transmitters

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about KEY Turbo S (TUS6324) - sliding gate operator for gates up to 600 kg

Product: KEY Turbo S (TUS6324) - sliding gate operator for gates up to 600 kg
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.