KEY Turbo S (TUS4324) – drive for a sliding gate weighing up to 400 kg


Product availability: for the question

The product may not be available, contact us for more information.


KEY Turbo S (TUS4324) – drive for a sliding gate weighing up to 400 kg KEY Turbo S (TUS4324) – drive for a sliding gate weighing up to 400 kg

Description of KEY Turbo S (TUS4324) – drive for a sliding gate weighing up to 400 kg

Drive unit KEY Turbo S (TUS4324) is designed for a sliding gate weighing up to 400 kg. It is equipped with a 24 V electric motor, so even intensive operation; there is no problem even with intensive operation. The gate leaf reaches a speed of 24 cm per second. The control unit is designated CT-10324 and the drive also includes a so-called electromechanical limit switch — a spring with microswitches. The drive has a built-in radio signal receiver. Download the manual >>.

Installation, wiring and setup
Drive unit onlyInstallationWiring
Manual releaseControl boardOverall diagram
Terminals and power supplyPhotocellsSafety inputs
Initial startupTravel learningProgramming
Remote controlsResetDiagnostics
MaintenanceTechnical specificationsSlovak PDF

KEY Turbo S TUS4324 – drive unit only

This is a non-reversible drive for a sliding gate with mechanical limit switches. The accessories shown in the diagrams are examples of wiring; they are not a list of items included with the drive unit only.

For installation and mechanical components, refer to the TURBO S manual. The operating procedures below apply to the CT10324 controller shown, with a five-digit display, UP, MENU, DOWN-RADIO and SBS buttons, and BASE/ADV menus. Before setup, compare the terminal labels and motor selection on your own board with the illustration shown.

The duty cycle does not allow unlimited continuous operation. A maximum of 40 cycles/hour applies to a reference gate leaf 4 m long and weighing 200 kg, at a temperature of 20 °C. For a longer gate leaf, reduce the number proportionally (8 m: by 50%); above 20 °C, reduce it by 15% for every additional 5 °C; for a gate at the maximum permitted weight, reduce it by 50%. The speed depends on the weight of the gate.

TURBO S dimensions: 335 × 190 × 280 mm; pinion position: 92 mm
TURBO S dimensions: 335 × 190 × 280 mm; pinion position: 92 mm

Mechanical installation of the drive

When released, the gate must move smoothly, must not start moving on its own, and must have secure mechanical stops in both the open and closed positions. The gate must run on a level track, not on an upward or downward slope. The installation site must not be prone to flooding. The manufacturer requires safety edges to protect all potential crushing points (hands, feet, and similar); other protective devices and their placement must be determined based on the risks presented by the specific gate.

Manufacturer's example of a sliding gate installation with a drive, photocells, warning light and safety edges
Manufacturer's example of a sliding gate installation with a drive, photocells, warning light and safety edges

The installation drawing shows the drive (2), photocells (3), warning light (4), key switch (5), control unit (6) and safety edges (7). The placement of safety devices must be based on the actual risks presented by the specific gate.

Base plate and fixing

Fixing the base plate to the substrate or concrete
Fixing the base plate to the substrate or concrete
  1. Determine the position based on the dimensions of the drive, base plate and rack. Install conduits for the cables. Secure the base plate to the substrate with sturdy anchor bolts, or set it in concrete as shown in the drawing.
  2. Release the drive and open the cover. Place the drive on the base plate and insert the two hex-socket fixing bolts. For an alternative fixing method, use the inner slots in the casting so that the fixings do not interfere with the cover.
  3. Level the drive. If adjusting the rack is not sufficient, use the four levelling screws as shown in figure 4.7. Tighten the two main fixing bolts securely; the drive must remain stable throughout the full travel. Check the fixings again after several movements.
Opening the cover, fixing, levelling and closing the drive again
Opening the cover, fixing, levelling and closing the drive again

Toothed rack and mechanical limit switches

Rack installation: maintain a 2 mm clearance between the rack and pinion
Rack installation: maintain a 2 mm clearance between the rack and pinion
  1. With the drive released, open the gate fully. Place the first rack section on the pinion and secure it to the gate with screws and spacers.
  2. Move the gate by hand; align the remaining sections using a spare piece of rack. After adjustment, maintain a 2 mm clearance, so that the weight of the gate does not rest on the drive pinion.
  3. At the ends of the travel, adjust the mechanical limit switch cams. Depending on the weight of the gate, leave a gap between the gate and the fixed mechanical stop of 30–50 mm; the cam should press the limit switch before the gate hits the stop.
  4. Secure the cams firmly as shown in the drawing, at both the open and closed positions. The stops must prevent derailment, and must be positioned so that the cam cannot strike the toothed wheel.
Adjusting and securing the mechanical limit switch cams
Adjusting and securing the mechanical limit switch cams

Wiring and separation of power supplies

The supply for this drive is 230 V AC, 50/60 Hz; the motor operates at 24 V DC. The control board itself is powered by a 24 V AC transformer. Do not mix up mains and low-voltage wiring. The supply must have protective earthing, suitable overcurrent protection, a residual-current device and a means of disconnection for overvoltage category III. Disconnect the mains supply and any backup power before opening or wiring.

Cables specified by the manufacturer for a typical installation
ConnectionCableMaximum length
230 V supply3 × 1.5 mm²; for lengths over 20 m, 3 × 2.5 mm²up to 20 m / over 20 m, maximum 50 m
FLASH warning light / LED auxiliary light3 × 0.55 mm²20 m
AntennaRG5810 m; less than 5 m recommended
Electric lock2 × 1.5 mm²10 m
Photocell TX2 × 0.55 mm²20 m
Photocell RX4 × 0.55 mm²20 m
Safety edge2 × 0.55 mm²20 m
Key switch4 × 0.55 mm²20 m
Motor2 × 1.5 mm²10 m

The cable must be suitable for the installation environment; the manufacturer specifies H03VV-F for indoor use and H05RN-F/H07RN-F for outdoor use. Connect the protective conductor at the control unit.

Manual release in the event of a power failure

  1. The gate must be stationary. Disconnect the power supply and secure the gate against unintended movement.
  2. Insert the release key and turn it 90° counterclockwise.
  3. Swing the release lever out so that it is perpendicular to the drive. You can now move the gate manually.
  4. Mechanically re-engage the drive before operating it again under motor power. Do not engage it while the motor is running; this could damage internal components.
Key and release lever for the TURBO S drive
Key and release lever for the TURBO S drive

CT10324 control board

Actual CT10324 control board with connector and control numbers
Actual CT10324 control board with connector and control numbers

Orientation as shown: heatsink on the left, display and control buttons on the right, main terminal blocks at the bottom. The labels on the board and in the diagrams remain unchanged. The M1+/M1− designation in the manual table corresponds to the M+/M− connector shown in the image.

Board legend based on the manufacturer's illustration
NumberComponent
1M+/M−, motor
2Power supply from transformer
3FLASH, IND/ELEC, LED
424 VAC for accessories
5PH-POW and NEG, safety device power supply
6Safety inputs
7Control inputs
8Safety and control input LEDs
9EDGE, PH2, PH1 DIP switches
10Limit switches
11Limit switch LEDs
12KBP/KBPN, backup battery charger
131.6 AT fuse, slow-blow
14Five-digit display
15SBS, step-by-step
16UP (+)
17MENU
18DOWN-RADIO (−)
19LED RADIO / KEY
20Antenna
21Optional SBK energy-saving module
22Optional KUBE / PowerBus interface

Complete wiring diagram for the board and accessories

The diagram shows the complete board, transformer and mains supply, ALIGHTEC flashing light, antenna, PH1 TX/RX photocells, and control contacts.

Complete manufacturer's CT10324 diagram: power supply, board, flashing light, photocells, antenna and control inputs
Complete manufacturer's CT10324 diagram: power supply, board, flashing light, photocells, antenna and control inputs

Terminals, polarity and power supply limits

Power supply and outputs of the control unit shown
TerminalsFunction and wiring
L / N / PEL = 230 V AC live; N = neutral; PE = protective earth. AC has no +/− polarity.
POWER SUPPLYSupply to the board from the transformer: 24 V AC (+10% / −15%), 50/60 Hz. Do not connect 230 V here.
M+ / M−Positive (+) and negative (−) terminals of the 24 V DC motor; also marked M1+/M1− in the image.
V+ / ENC / NEG at the motorIn this wiring configuration, do not use; this is not the photocell power supply.
24 VAC / 24 VACAccessory pair: unregulated 24 V AC, maximum 200 mA. No +/− polarity; inactive when operating on battery power.
PH-POW / NEGPH-POW = positive (+) pole, NEG = negative (−) pole of the unregulated 24 V DC supply for safety devices; PH-POW limit is 200 mA. The mode is related to PHOTO TEST.
COM at the outputsCommon positive (+) pole for the FLASH, IND/ELEC and LED outputs.
FLASHConnect the flashing light between COM (+) and switched FLASH (−): 24 V DC, maximum 15 W. The output can be set to steady or flashing operation.
LEDConnect auxiliary lighting between COM (+) and switched LED (−): unregulated 24 V DC, maximum 15 W.
IND/ELECCommon COM (+), switched IND/ELEC (−). IND mode: indicator light, 24 V DC / maximum 5 W. ELEC mode: electric lock, 12 V DC / maximum 15 VA. The mode is set using INDIC LIGHT.
COM at the inputsCommon point for PH2, PH1, OPEN, CLOSE, PAR and SBS; positive internally. A control or safety contact is voltage-free; no +/− polarity is assigned to its terminals.
LS1 / LS2 / COMLimit switch connector; check the corresponding LEDs.
BATTERIESConnect the KBP/KBPN charger according to the relevant instructions.
ANT / SHIELDANT = signal, coaxial cable centre conductor; SHIELD = shielding. This is not a +/− power supply pair.

The total current drawn by all devices on the relevant power supply output must remain within its limit. Do not confuse the unregulated DC output with 24 V AC. For accessories, use the terminal block terminals shown in the diagram, not NEG/V+/ENC at the motor connector.

PH1 and PH2 photocells – polarity-sensitive wiring

Factory wiring for both PH1 and PH2 photocell pairs; original wires, jumpers and terminal labels
Factory wiring for both PH1 and PH2 photocell pairs; original wires, jumpers and terminal labels

Standard DC photocell wiring according to the factory diagram
DeviceConnection to the four-terminal RX shown
TX units for both pairsTX 1 / NEG (−) → board NEG; TX 2 / POS (+) → board PH-POW.
RX units for both pairsRX 1 / NEG (−) → board NEG; RX 2 / POS (+) → COM (+).
PH1 RX contactRX 3 / COM → board COM; RX 4 / OUT (NC) → PH1. The RX 2–3 jumper is shown in the original diagram.
PH2 RX contactRX 3 / COM → board COM; RX 4 / OUT (NC) → PH2. The RX 2–3 jumper is shown in the original diagram.

Numbers 1–4 apply only to the TX/RX units shown. Other photocells may have different terminals; connect their power supply and NC contact according to their own instructions. COM and OUT on the receiver are relay contacts, not power supply +/− terminals. When wired according to this diagram, the common contact point is connected to the board's COM terminal.

PH1 during closing, it stops and reverses movement; while active, the gate cannot be closed. PH2 depending on the setting, it protects opening or both directions; when the circuit opens, it stops movement and resumes opening once released. FOTO1 SETUP and FOTO2 SETUP change how it operates.

Photocell test and energy-saving mode

During the photocell test, TX power is controlled via PH-POW. In ADV, set PHOTO TEST: 0 off, 1 PH1, 2 PH2, 3 both pairs. Test only correctly connected devices.

Separate factory wiring diagram for STAND BY energy-saving mode
Separate factory wiring diagram for STAND BY energy-saving mode

In the energy-saving wiring configuration, the positive power supplies for both TX and RX are connected to PH-POW (+), and the negative supplies to NEG (−); RX contacts remain between COM and PH1/PH2. STAND BY is enabled in BASE. PHOTOTEST is not available when STAND BY is enabled. Do not combine these two wiring diagrams.

Safety and control inputs

Contacts are volt-free; do not connect an external voltage to them
InputFunction
EDGE/STOP, pairVolt-free STOP NC input or safety edge; TYPE EDGE: 0 STOP NC, 1 8k2 resistive, 2 NC contact, 3 dual 4k1 resistive. When the safety edge is triggered, it briefly reverses movement and stops.
PH1 / COMNC contact of the closing photocell.
PH2 / COMNC contact of the photocell, according to the selected mode.
OPEN / COMNO opening contact.
CLOSE / COMNO closing contact.
SBS / COMNO step-by-step contact, as set by SBS SETUP.
PAR/EDGE / COMNO partial-opening contact; the STOP TWO parameter allows it to be changed to STOP or a second opening safety edge.

The second safety edge on PAR/EDGE is configured via STOP TWO. For EDGE2, SETUP EDGE must be set to 0 so that the first safety edge, EDGE1, is triggered only during closing. EDGE2 protects opening and briefly reverses movement when activated. The EDGE DIP switch does not disable this second input.

EDGE, PH2 and PH1 DIP switches on the control board
EDGE, PH2 and PH1 DIP switches on the control board

The ON position disables the corresponding safety function. When safety devices are in use, the corresponding DIP switch must be in the OFF position. An unused input may be disabled only in accordance with the installation's safety design: set its DIP switch to ON and confirm by holding UP (+) and DOWN-RADIO (−), until the LED for that input stops flashing. This is not a fix for faulty photocells or a faulty safety edge.

Initial startup and motor selection

  1. Check the mechanical fixings, stops, rack, free movement, earthing and correct wiring of the safety devices. Switch on the power only after completing the wiring.
  2. When the travel has not been learned, LEARN TO DO is displayed. Press UP to cycle through the status, cycle count, motor current and board type, firmware and serial number; MENU returns to the normal display.
  3. Before learning, set the correct model in ADV → MOTOR SETUP. For KEY Turbo S TUS4324, the option shown in the menu is 0. Select the value according to the model list for the board; changing the motor type restores the factory parameters and requires the travel to be learned again.

Automatic travel learning

Learning with the standard deceleration range

  1. Disengage the drive, move the gate to approximately halfway along its travel, then re-engage the drive.
  2. Press and hold UP (+) and MENU for approximately two seconds. The gate will start opening slowly; the display shows LEARN OPEN1.
  3. If the gate starts closing instead of opening, stop it using DOWN-RADIO (−). Use the SBS button to restart learning in the opposite direction.
  4. The motor stops at the opening limit switch. After approximately two seconds, it starts closing; the display indicates that closing is being learned.
  5. Learning ends when the gate reaches the closing limit switch. Then run several complete cycles and test all safety devices and forces.

Learning must be completed fully and correctly before handover. According to the manufacturer, it can be interrupted by triggering EDGE, PH2 or PH1, or by disconnecting the power supply. After successful learning, BASE/ADV parameters can be changed.

Custom deceleration points

In BASE, select P (custom setting) for LENGH SLOW and start learning from halfway along the travel, as described above. Once the gate reaches the open position, the drive starts closing. At the desired deceleration point during closing, press SBS; the display shows CLOS1 SLOW. After closing, it starts opening again; press SBS at the deceleration point during opening (OPEN1 SLOW). Once the gate reaches the open position, the final closing cycle follows. If a point is not specified, it is automatically set to 20% of the full travel.

Programming BASE and ADV

  1. Press and hold MENU. When BASE is displayed, release the button to open the basic menu; to access ADV, keep holding it for approximately five seconds and release when ADV appears.
  2. Use UP and DOWN-RADIO to scroll through the items. The name and value alternate on the display.
  3. To edit, hold MENU until the value starts flashing, then release the button. Change the value using UP/DOWN-RADIO.
  4. Hold MENU until the display stops flashing to save the new value. Press MENU briefly to exit the menu.

The tables show the meaning and available options. Force, speed and safety-function settings must be based on measurements taken on the specific gate. A higher REACT TIME value means lower impact force, not a more powerful motor.

1. AUTO CLOSE

0–900 s; 0 = automatic closing disabled.

2. PHOTO CLOSE

0–30 s; closing time after passing through PH1, 0 = disabled.

3. REACT TIME

0–10; 0 = maximum impact force, 10 = minimum.

4. OPEN SPEED

1–5; opening speed from minimum to maximum.

5. SL-OP SPEED

1–5; opening speed during deceleration.

6. CLOSE SPEED

1–5; closing speed from minimum to maximum.

7. SL-CL SPEED

1–5; closing speed during deceleration.

8. SBS SETUP

0: open–stop–close–stop; 1: open–stop–close–open; 2: open–close; 3: apartment-block mode with timer (AUTO CLOSE ≠ 0); 4: apartment-block mode with immediate closing.

9. STOP TWO

0 = disabled; 1 = PAR as STOP NO; 2 = STOP NC; 3 = NC safety edge; 4 = 8k2 safety edge; 5 = 4k1 safety edge. For EDGE2, SETUP EDGE must be set to 0; the DIP switch does not affect this second input.

10. LENGH SLOW

P = custom points learned automatically; 15–100% of the travel for deceleration during opening and closing.

11. BLACK OUT

0 = no action after a power outage; 1 = closing.

12. STAND BY

0 = off; 1 = energy saving by switching off the photocells when the gate is closed. Requires the appropriate wiring; PHOTOTEST is not available with this function.

1. FOTO1 SETUP

0 = checks PH1 before opening from the closed position; 1 = opens even when PH1 is activated.

2. FOTO2 SETUP

0 = PH2 active in both directions; 1 = opening only; 2 = activation switches on auxiliary lighting for TIME LIGHT.

3. PHOTO TEST

0 = off; 1 = PH1 test; 2 = PH2 test; 3 = test of both pairs.

4. TYPE EDGE

0 = STOP NC; 1 = 8k2 resistive safety edge; 2 = NC contact safety edge; 3 = dual 4k1 resistive safety edge.

5. SETUP EDGE

0 = EDGE1 active during closing; 1 = EDGE1 active during both opening and closing. When triggered, it briefly reverses the movement. For a second safety edge on PAR, this must remain set to 0.

6. TEST EDGE

0 = safety edge test off; 1 = on.

7. SETUP PART

0–100%; partial opening range.

8. CLOSE PART

0–900 s; closing time from partial opening, 0 = off.

9. FLASH SETUP

0 = steady output; 1 = flashing.

10. PRE SETUP

0 = pre-flashing before opening and closing; 1 = before closing; 2 = before opening. Disabled when PRE TIME = 0.

11. PRE TIME

0–20 s; pre-flash duration, 0 = off.

12. SETUP LIGHT

0 = light stays on after movement ends for TIME LIGHT; 1 = while the gate is open, then for TIME LIGHT; 2 = for the set TIME LIGHT duration.

13. TIME LIGHT

0–900 s; auxiliary lighting duration.

15. WIND REACT

0 = off; 1 = if an attempt is made to open the closed gate, the drive will try to close it again.

16. HOLD TO RUN

0 = normal operation; 1 = movement while the control contact is held.

17. INDIC LIGHT

0 = off; 1 = open indicator light; 2 = slow flashing during opening, fast flashing during closing, steady light when open, two flashes and a pause when stopped before fully closing; 3 = electric lock; 4 = magnetic lock with an active output when closed, via an external relay with a 24 V DC coil.

18. CYCLE SERVI

0–200 × 1,000 cycles; service interval, 0 = off.

19. SETUP SERVI

0 = off; 1 = service reminder indicated by continuous flashing when the gate is closed, if CYCLE SERVI is non-zero.

20. ELECT TIME

1–10 s; electric lock activation time, or deactivation time for a magnetic lock.

21. BOOST SETUP

0 = off; 1 = high-speed start.

22. ENCOD SETUP

Encoder type display: 0 = virtual, 1 = physical. In the wiring configuration shown in this manual, the V+/ENC/NEG terminals at the motor are not used.

23. MOTOR SETUP

Model selection and factory reset. For KEY Turbo S TUS4324, use the value 0 in the corresponding motor list displayed by the controller; the procedure is described below under Reset.

Remote controls and integrated receiver

The controller has a 433.92 MHz OOK receiver with a memory capacity of 150 transmitters. To enter RADIO, hold DOWN-RADIO for approximately two seconds. Exit the menu by briefly pressing MENU, or it will close after seven seconds of inactivity. Program the remote near the control board; if you disconnect the antenna wire to reduce interference, reconnect it afterward.

Saving a remote-control button

  1. Exit any other menu and hold DOWN-RADIO until RADIO MENU appears.
  2. Briefly press DOWN-RADIO to select the function according to the number of presses shown in the table. The KEY LED flashes the corresponding number of times, with a pause of about one second.
  3. Within seven seconds, hold the desired remote-control button near the control board for a few seconds. For LEARN ALL, any button can be pressed.
  4. A long flash of the KEY LED lasting about three seconds confirms that the button has been saved. A series of short flashes means the button is already in the memory. The same function can be assigned to another button within the next seven seconds.

Selecting a function when programming the radio
PressesFunction
1LEARN SBS – step-by-step
2LEARN PAR – partial opening
3LEARN OPEN – opening only
4LEARN LIGHT – switch lighting on/off
5LEARN ALL – buttons 1 SBS, 2 partial, 3 open only, 4 lighting

The light switched on by the remote control is switched off by the remote control.

Deleting a stored button

  1. Enter RADIO MENU.
  2. Hold DOWN-RADIO until the KEY LED lights up; then release the button.
  3. Within seven seconds, hold the remote control button to be deleted until the KEY LED starts flashing; release it.
  4. Confirm deletion with DOWN-RADIO. A long flash of the KEY LED confirms deletion.

If the remote control was stored using LEARN ALL, this procedure deletes all its assigned functions.

Deleting the entire remote control memory

  1. In RADIO MENU, hold DOWN-RADIO: the KEY LED lights up after about three seconds; keep holding until it goes out, then release the button.
  2. The LED starts flashing slowly. At the third flash briefly press DOWN-RADIO.
  3. A long flash of the KEY LED confirms that all remote controls have been deleted.

Adding a new remote control using one that is already stored

  1. At the control unit, hold a button on the new remote control for at least five seconds.
  2. On the remote control that is already stored, hold the button for the desired function for at least three seconds. If the first step was performed correctly, the gate will not move during this step.
  3. Again, hold the same button on the new remote control for at least three seconds.
  4. Again, hold the same button on the old remote control for at least three seconds. Successful storage is confirmed when the copied command is executed.

Restoring factory settings

Resetting settings via MOTOR SETUP and deleting remote controls are separate procedures. If the motor type is not changed, the manual specifies restoring the factory settings without needing to relearn the travel path. If you change the type, you must relearn the travel path.

  1. Hold MENU until ADV appears. Use UP/DOWN-RADIO to select MOTOR SETUP.
  2. Hold MENU until the motor type number starts flashing.
  3. Select value 0 for KEY Turbo S TUS4324, as specified in the board's corresponding motor list.
  4. Hold MENU during the countdown 50 → 0. Release when DONE appears. Exit the menu with a brief press of MENU or after seven seconds of inactivity.

Display, input and warning light diagnostics

First, eliminate the cause. The error message will then clear after a full movement to the relevant limit switch, or by briefly pressing MENU without moving the gate. Work on the mechanism and terminal blocks only after disconnecting the power supply.

Operating and error messages
MessageMeaning / check
LEARN TO DOThe travel path has not been learned.
READYGate closed; control unit restarted.
OPEN ING / CLOSE INGOpening / closing in progress.
STOP OPEN / STOP CLOSEMovement stopped while opening / closing.
FOTO1 / FOTO2PH1 / PH2 input active; check the photocells, any obstruction and the wiring.
ALIGN MENTPosition recovery in progress.
OPENGate open with no active closing timer.
PAR TIAL / PART OPENPartial opening / stopped in the partially open position.
TIME CLOSE / TIME PARTClosing timer after full / partial opening; the remaining time is displayed during the last ten seconds.
LEARN STOPLearning stopped by a safety device being triggered or by an intentional stop.
LEARN OPEN1 / LEARN CLOS1Learning the opening / closing travel path.
SLOW OPEN1 / SLOW CLOS1Determining the slowdown points automatically.
OVER LOAD1Motor current has increased sharply; check for an obstruction and mechanical resistance.
EDGESafety edge active or incorrectly wired.
FOTO TESTPhotocell or safety edge test failed; check operation and wiring.

Signals according to the manufacturer's manual
Flashing warning light / KEY LEDEvent
2 quick flashes + pause + 1Automatic learning
4 quick flashes + pause, three timesObstruction detected
2 quick flashes + pause, three timesPH1/PH2 photocell triggered
5 quick flashes + pause, three timesSafety edge triggered
3 quick flashes + pause, three timesPhotocell or safety edge test failure
6 quick flashes + pause, three timesShort circuit or overload on the FLASH, IND/ELEC or LED output

Press UP repeatedly to display the number of complete cycles (NCY), the instantaneous motor current in mA, and the board type/firmware version/serial number. Red LEDs are for safety inputs and limit switches; green LEDs are for control inputs. A flashing LED after changing a safety DIP switch requires the appropriate confirmation; do not disable functioning safety devices as a way to resolve a fault.

Checks and maintenance

Before handover, test all components, photocells, safety edges, commands, stops and manual release, and measure the impact forces. Provide the manual, safety instructions, documentation and maintenance schedule. For normal domestic use, the manufacturer recommends an inspection every six months; adjust the interval according to usage.

When the system is safely switched off and released, users may clean the photocell lenses with a slightly damp cloth and remove leaves or stones. Carry out functional and safety tests after repairs or changes to settings. In the event of a fault, disconnect the power supply and call a service technician; faulty safety devices must be repaired immediately. Keep the key and remote controls out of children's reach.

Technical specifications of KEY Turbo S TUS4324

Specifications of the drive unit
SpecificationValue
Brand:KEY Automation
Model:Turbo S (TUS4324)
Control unit:CT-10324
Drive supply voltage:230 V
Motor supply voltage:24V
Limit stop:electromechanical switch
Power consumption:250 W
Motor current:1,1 A
Pinion module:M4
Max. load:400 kg
Speed:24 cm/s
Protection rating:IP44
Operating temperature:-20 / +55 °C
Torque12 Nm
Dimensions (L × W × H)335 × 190 × 280 mm
Drive weight7 kg
Maximum cycles/h40 under the reference conditions specified above
Noise≤ 70 dB(A)
Integrated receiver433.92 MHz OOK; 150 transmitters

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about KEY Turbo S (TUS4324) – drive for a sliding gate weighing up to 400 kg

Product: KEY Turbo S (TUS4324) – drive for a sliding gate weighing up to 400 kg
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.