KEY Turbo S (TUS11324) - drive for sliding gates weighing up to 1100 kg
| Product availability: | within 14 days | We normally dispatch goods within 14 days. |
|---|
within 14 days
€485.99 including VAT
| Weight |
|---|
| 10 kg |
Description of KEY Turbo S (TUS11324) - drive for sliding gates weighing up to 1100 kg
Operator KEY Turbo S (TUS11324) is designed for a sliding gate up to 1,100 kg. It is equipped with a 24 V electric motor, so even intensive use. The gate leaf reaches a speed of 20 cm per second. The control unit is designated CT-10324 and the operator also includes a so-called electromechanical limit switch — a spring with microswitches. The operator has a built-in radio signal receiver.
KEY Turbo S TUS11324 – operator only
This is a non-reversible operator for a sliding gate with mechanical limit switches. The accessories shown in the diagrams are examples of wiring only; they are not a list of items included with the operator-only product.
For installation and mechanical details, refer to the TURBO S manual. The operating procedures below apply to the CT10324 control unit shown, with a five-digit display, UP, MENU, DOWN-RADIO and SBS buttons, and BASE/ADV menus. Before setting up, compare the terminal labels and motor selection on your own board with the illustration provided.
The duty cycle does not allow unlimited continuous operation. A maximum of 50 cycles/hour applies to a reference gate leaf 4 m long, weighing 200 kg, at a temperature of 20 °C. For a longer gate leaf, reduce the number proportionally (8 m: by 50%); above 20 °C, reduce it by 15% for every additional 5 °C; for a gate at the maximum permitted weight, reduce it by 50%. The speed depends on the gate's weight.

Mechanical installation of the operator
When released, the gate must move smoothly and must not move off by itself. It must have solid mechanical stops at both the open and closed positions. The gate must run along a level track, not up or down a slope. The installation site must not be subject to flooding. The manufacturer requires safety edges to protect all potential crushing points (hands, feet and similar); other protective devices and their placement must be determined based on the risks presented by the specific gate.

Accessories list
- 2 – operator
- 3 – photoelectric cells
- 4 – warning beacon
- 5 – key switch
- 6 – remote control
- 7 – safety edges
The positioning of safety devices must be based on the actual risks presented by the specific gate.
Foundation plate and fastening

- Determine the position based on the dimensions of the operator, foundation plate and rack. Install conduits for the wiring. Fasten the foundation plate with sturdy anchor bolts or set it in concrete as shown in the drawing.
- Release the operator and open the cover. Place the operator on the foundation plate and insert the two Allen-head fastening screws. For alternative fastening, use the inner slots in the casting to ensure the fasteners do not interfere with the cover.
- Level the operator. If the rack adjustment is insufficient, use the four levelling screws as shown in figure 4.7. Tighten the two main fastening screws securely; the operator must remain stable throughout the full travel. Check the fastening again after several movements.

Rack and mechanical limit switches

- With the operator released, open the gate fully. Place the first rack section on the pinion and fasten it to the gate with screws and spacers.
- Move the gate by hand, aligning the next rack sections with a spare piece of rack. After adjustment, maintain a 2 mm clearance, so the weight of the gate does not rest on the operator's pinion.
- At the ends of the travel, adjust the mechanical limit-switch cams. Depending on the gate's weight, leave a gap of 30–50 mmbetween the gate and the fixed mechanical stop; the cam should actuate the limit switch before the gate hits the stop.
- Securely fasten the cams as shown in the drawing at both the open and closed positions. The stops must prevent derailment, and their position must prevent the cam from striking the gear wheel.

Wiring and power-supply separation
The power supply for this operator is 230 V AC, 50/60 Hz; the motor operates at 24 V DC. The control board itself is powered by a 24 V AC transformer. Do not mix up mains and low-voltage wiring. The power supply must have protective earthing, suitable overcurrent protection, a residual-current device and a means of disconnection for overvoltage category III. Disconnect the mains supply and any backup power before opening or wiring the unit.
| Connection | Cable | Maximum length |
|---|---|---|
| 230 V supply | 3 × 1.5 mm²; for lengths over 20 m, 3 × 2.5 mm² | up to 20 m / over 20 m, maximum 50 m |
| FLASH warning beacon / LED auxiliary light | 3 × 0.55 mm² | 20 m |
| Antenna | RG58 | 10 m; less than 5 m recommended |
| Electric lock | 2 × 1.5 mm² | 10 m |
| TX photocell | 2 × 0.55 mm² | 20 m |
| RX photocell | 4 × 0.55 mm² | 20 m |
| Safety edge | 2 × 0.55 mm² | 20 m |
| Key switch | 4 × 0.55 mm² | 20 m |
| Motor | 2 × 1.5 mm² | 10 m |
The cable must be suitable for the installation environment; the manufacturer specifies H03VV-F for indoor use and H05RN-F/H07RN-F for outdoor use. Connect the protective conductor at the control unit.
Manual release in the event of a power failure
- The gate must be stationary. Disconnect the power supply and secure the gate against unintended movement.
- Insert the release key and turn it 90° counterclockwise.
- Swing the release lever out until it is perpendicular to the drive. You can now move the gate manually.
- Mechanically re-engage the drive before operating it again under motor power. Do not re-engage it while the motor is running; this could damage the internal components.

CT10324 control board

Orientation as shown: heat sink on the left, display and control buttons on the right, main terminal blocks at the bottom. The labels on the board and in the diagrams remain unchanged. The M1+/M1− designation in the instruction manual table corresponds to the M+/M− connector shown in the image.
Board labels
- 1 – M+/M−, motor
- 2 – Transformer power supply
- 3 – FLASH, IND/ELEC, LED
- 4 – 24 VAC for accessories
- 5 – PH-POW and NEG, power supply for safety devices
- 6 – Safety inputs
- 7 – Control inputs
- 8 – LEDs for safety and control inputs
- 9 – EDGE, PH2, PH1 DIP switches
- 10 – Limit switches
- 11 – Limit switch LEDs
- 12 – KBP/KBPN, backup battery charger
- 13 – 1.6 AT fuse, slow-blow
- 14 – Five-digit display
- 15 – SBS, step-by-step
- 16 – UP (+)
- 17 – MENU
- 18 – DOWN-RADIO (−)
- 19 – RADIO / KEY LED
- 20 – Antenna
- 21 – Optional SBK energy-saving module
- 22 – Optional KUBE / PowerBus interface
Complete wiring diagram of the board and accessories
The diagram shows the complete board, transformer and mains supply, ALIGHTEC warning light, antenna, PH1 TX/RX photocells, and control contacts.

Terminals, polarity and power supply limits
| Terminals | Function and wiring |
|---|---|
| L / N / PE | L = 230 V AC live; N = neutral; PE = protective earth. AC has no +/− polarity. |
| POWER SUPPLY | Power supply to the board from the transformer: 24 V AC (+10% / −15%), 50/60 Hz. Do not connect 230 V here. |
| M+ / M− | Positive (+) and negative (−) terminals for the 24 V DC motor; also labelled M1+/M1− in the image. |
| V+ / ENC / NEG at the motor | In this wiring configuration do not use; these are not the photocell power supply terminals. |
| 24 VAC / 24 VAC | Pair of terminals for accessories: unregulated 24 V AC, maximum 200 mA. No +/− polarity; inactive when operating on battery power. |
| PH-POW / NEG | PH-POW = positive (+) pole, NEG = negative (−) pole of the unregulated 24 V DC supply for safety devices; PH-POW is limited to 200 mA. The mode is associated with PHOTO TEST. |
| COM at the outputs | Common positive (+) pole for the FLASH, IND/ELEC and LED outputs. |
| FLASH | Connect the warning light between COM (+) and the switched FLASH (−): 24 V DC, maximum 15 W. The output can be set to steady or flashing operation. |
| LED | Connect the auxiliary light between COM (+) and the switched LED (−): unregulated 24 V DC, maximum 15 W. |
| IND/ELEC | Common COM (+), switched IND/ELEC (−). IND mode: indicator light, 24 V DC / maximum 5 W. ELEC mode: electric lock, 12 V DC / maximum 15 VA. The mode is set using INDIC LIGHT. |
| COM at the inputs | Common point for PH2, PH1, OPEN, CLOSE, PAR and SBS; internally positive. A control or safety contact is voltage-free; no +/− polarity is specified at its terminals. |
| LS1 / LS2 / COM | Limit switch connector; check the corresponding LEDs. |
| BATTERIES | Connect the KBP/KBPN charger according to the relevant manual. |
| ANT / SHIELD | ANT = signal, coaxial cable core; SHIELD = shielding. This is not a +/− power supply pair. |
The total current drawn by all devices connected to the relevant power supply output must remain within its limit. Do not confuse the unregulated DC output with 24 V AC. For accessories, use the terminal block terminals indicated in the diagram, not NEG/V+/ENC at the motor connector.
PH1 and PH2 photocells – polarity-sensitive wiring

| Device | Connection to the four-terminal RX shown |
|---|---|
| TX units for both pairs | TX 1 / GND (−) → board NEG; TX 2 / 12/24 AC/DC (+) → board PH-POW. |
| RX units for both pairs | RX 1 / GND (−) → board NEG; RX 2 / 12/24 AC/DC (+) → COM (+). |
| PH1 RX contact | RX 3 / COM → board COM; RX 4 / OUT (NC) → PH1. The RX 2–3 jumper is shown in the original diagram. |
| PH2 RX contact | RX 3 / COM → board COM; RX 4 / OUT (NC) → PH2. The RX 2–3 jumper is shown in the original diagram. |
Numbers 1–4 apply exclusively to the TX/RX shown. Other photocells may have different terminals; connect their power supply and NC contact according to their own instructions. COM and OUT on the receiver are relay contacts, not power supply +/−. When wired according to this diagram, the contact common is connected to the board’s COM.
PH1 stops and reverses movement during closing; while it is active, the gate cannot be closed. PH2 depending on the setting, protects opening or both directions; when the circuit opens, it stops movement and resumes opening once the obstruction is cleared. FOTO1 SETUP and FOTO2 SETUP change how it operates.
Photocell test and standby mode
During the photocell test, TX power is controlled via PH-POW. In ADV, set PHOTO TEST: 0 off, 1 PH1, 2 PH2, 3 both pairs. Test only correctly connected devices.

In standby wiring, the positive supplies for both TX and RX are connected to PH-POW (+), and the negatives to NEG (−); the RX contacts remain between COM and PH1/PH2. STAND BY is enabled in BASE. PHOTOTEST is not available when STAND BY is enabled. Do not combine these two diagrams.
Safety and control inputs
| Input | Function |
|---|---|
| EDGE / EDGE (STOP/EDGE), pair | Voltage-free STOP NC input or safety edge; TYPE EDGE: 0 STOP NC, 1 8k2 resistive, 2 NC contact, 3 dual 4k1 resistive. When the safety edge is triggered, it briefly reverses movement and stops. |
| PH1 / COM | NC contact for the closing photocell. |
| PH2 / COM | NC photocell contact, depending on the selected mode. |
| OPEN / COM | NO opening contact. |
| CLOSE / COM | NO closing contact. |
| SBS / COM | NO step-by-step contact, according to SBS SETUP. |
| PAR (PED) / COM | NO partial-opening contact; the STOP TWO parameter allows it to be changed to STOP or a second opening safety edge. |
The second safety edge on PAR (PED) is configured via STOP TWO. For EDGE2, SETUP EDGE must be set to 0 so that the first safety edge, EDGE1, is triggered only during closing. EDGE2 protects during opening and briefly reverses movement when activated. The EDGE DIP switch does not disable this second input.

The ON position disables the corresponding safety function. When safety devices are used, the corresponding DIP switch must be set to OFF. An unused input may be disabled only in accordance with the installation’s safety design: set its DIP switch to ON and confirm by pressing and holding UP (+) and DOWN-RADIO (−), until the LED for that input stops flashing. This is not a fix for faulty photocells or a faulty safety edge.
Initial startup and motor selection
- Check the mechanical mounting, stops, rack, free movement, grounding, and correct connection of the safety devices. Switch on the power only after completing the wiring.
- When the travel limits have not been learned, LEARN TO DO is displayed. Press UP to cycle through the status, cycle count, motor current, and board type, firmware and serial number; MENU returns to the normal display.
- Before learning, set the correct model in ADV → MOTOR SETUP. For KEY Turbo S TUS11324, the displayed menu option is 3. Select the value according to the model list for the board; changing the motor type restores factory parameters and requires the travel limits to be learned again.
Automatic travel learning
Learning with the standard slowdown range
- Disengage the drive, move the gate to approximately halfway along its travel, then re-engage the drive.
- Press and hold UP (+) and MENU for approximately two seconds. The gate will begin to open slowly; the display shows LEARN OPEN1.
- If the gate closes instead of opening, stop it with DOWN-RADIO (−). Use the SBS button to restart learning in the opposite direction.
- The motor stops at the opening limit switch. After approximately two seconds, it starts closing; the display shows the closing-learning status.
- Learning ends when the closing limit switch is reached. Then run several complete cycles and test all safety devices and forces.
Learning must be completed fully and correctly before handover. According to the manufacturer, learning is interrupted by triggering EDGE, PH2 or PH1, or by disconnecting the power supply. After successful learning, BASE/ADV parameters can be changed.
Custom slowdown points
In BASE, set LENGH SLOW to P (custom setting) and start learning from halfway along the travel, as described above. Once the open position is reached, the drive starts closing. At the required slowdown point during closing, press SBS; the display shows CLOS1 SLOW. Once closed, the gate starts opening again; press SBS at the slowdown point during opening (OPEN1 SLOW). Once the open position is reached, the final closing movement follows. Any point that is not entered is automatically set to 20% of the total travel.
Programming BASE and ADV
- Press and hold MENU. When BASE is displayed, release the button to open the basic menu; to open ADV, keep holding for approximately five seconds and release when ADV appears.
- Browse the items using UP and DOWN-RADIO. The name and value alternate on the display.
- To edit, press and hold MENU until the value starts flashing, then release the button. Change the value using UP/DOWN-RADIO.
- Press and hold MENU until the display stops flashing to save the new value. Press MENU briefly to exit the menu.
The tables show the meaning and available options. Force, speed and safety-function settings must be based on measurements taken on the specific gate. A higher REACT TIME value means less impact force, not a more powerful motor.
Basic menu BASE
1. AUTO CLOSE
0–900 s; 0 = automatic closing disabled.
2. PHOTO CLOSE
0–30 s; closing time after passing through PH1, 0 = disabled.
3. REACT TIME
0–10; 0 = maximum impact force, 10 = minimum.
4. OPEN SPEED
1–5; opening speed from minimum to maximum.
5. SL-OP SPEED
1–5; opening speed during slowdown.
6. CLOSE SPEED
1–5; closing speed from minimum to maximum.
7. SL-CL SPEED
1–5; closing speed during slowdown.
8. SBS SETUP
0: open–stop–close–stop; 1: open–stop–close–open; 2: open–close; 3: apartment-block mode with timer (AUTO CLOSE ≠ 0); 4: apartment-block mode with immediate closing.
9. STOP TWO
0 = disabled; 1 = PAR as STOP NO; 2 = STOP NC; 3 = NC opening safety edge; 4 = 8k2 opening safety edge; 5 = 4k1 opening safety edge. For EDGE2, SETUP EDGE must be set to 0; the DIP switch does not affect this second input.
10. LENGH SLOW
P = learning points; 1–100% of the travel for slowing down during opening and closing.
11. BLACK OUT
0 = no action after a power failure; 1 = close.
12. STAND BY
0 = off; 1 = energy saving by switching off the photocells when the gate is closed. Requires the appropriate wiring; PHOTOTEST is not available with this function.
Advanced menu ADV
1. FOTO1 SETUP
0 = checks PH1 before opening from the closed position; 1 = opens even when PH1 is activated.
2. FOTO2 SETUP
0 = PH2 active in both directions; 1 = opening only; 2 = activation switches on the auxiliary lighting for TIME LIGHT.
3. PHOTO TEST
0 = off; 1 = PH1 test; 2 = PH2 test; 3 = test of both pairs.
4. TYPE EDGE
0 = STOP NC; 1 = 8k2 resistive safety edge; 2 = NC contact safety edge; 3 = 4k1 dual resistive safety edge.
5. SETUP EDGE
0 = EDGE1 active during closing; 1 = EDGE1 active during both opening and closing. When triggered, it briefly reverses the movement. For a second safety edge on PAR, this must remain at 0.
6. TEST EDGE
0 = safety edge test off; 1 = on.
7. SETUP PART
0–100%; partial opening range.
8. CLOSE PART
0–900 s; closing time from partial opening, 0 = off.
9. FLASH SETUP
0 = steady output; 1 = flashing output.
10. PRE SETUP
0 = pre-flashing before both opening and closing; 1 = before closing; 2 = before opening. Disabled when PRE TIME = 0.
11. PRE TIME
0–20 s; pre-flashing time, 0 = off.
12. SETUP LIGHT
0 = light stays on for TIME LIGHT after movement ends; 1 = while the gate is open, then for TIME LIGHT; 2 = for the set TIME LIGHT duration.
13. TIME LIGHT
0–900 s; auxiliary lighting time.
15. WIND REACT
0 = off; 1 = when an attempt is made to open the closed gate, the drive tries to close it again.
16. HOLD TO RUN
0 = normal operation; 1 = movement while the control contact is held.
17. INDIC LIGHT
0 = off; 1 = open indicator; 2 = slow flashing while opening, fast flashing while closing, steady light when open, two flashes and a pause when stopped before fully closed; 3 = electric lock; 4 = magnetic lock with the output active when closed, via an external relay with a 24 V DC coil.
18. CYCLE SERVI
0–200 × 1,000 cycles; service interval, 0 = off.
19. SETUP SERVI
0 = off; 1 = service reminder indicated by continuous flashing when the gate is closed, if CYCLE SERVI is non-zero.
20. ELECT TIME
1–10 s; electric lock activation time, or deactivation time for a magnetic lock.
21. BOOST SETUP
0 = off; 1 = high-speed start.
22. ENCOD SETUP
Encoder type display: 0 = virtual, 1 = physical. In the wiring shown in this manual, the V+/ENC/NEG terminals at the motor are not used.
23. MOTOR SETUP
Select the model and restore factory settings. For KEY Turbo S TUS11324, use value 3 in the corresponding motor list shown on the controller; the procedure is described below in the Reset section.
Remote controls and integrated receiver
The controller has a 433.92 MHz OOK receiver with a capacity of 150 transmitters. To enter RADIO, hold DOWN-RADIO for approximately two seconds. Exit the menu by briefly pressing MENU, or it will close after seven seconds of inactivity. Program the remote near the control board; if you disconnect the antenna wire to reduce interference, reconnect it afterwards.
Storing a remote-control button
- Exit any other menu and hold DOWN-RADIO until RADIO MENU appears.
- Briefly press DOWN-RADIO to select the function according to the number of presses shown in the table. The KEY LED flashes the corresponding number of times, with a pause of about one second.
- Within seven seconds, hold the desired remote-control button near the control board for a few seconds. For LEARN ALL, any button can be pressed.
- A long flash of the KEY LED for approximately three seconds confirms storage. A series of short flashes means the button is already in memory. Within the next seven seconds, the same function can be assigned to another button.
| Number of presses | Function |
|---|---|
| 1 | LEARN SBS – step-by-step |
| 2 | LEARN PAR – partial opening |
| 3 | LEARN OPEN – opening only |
| 4 | LEARN LIGHT – switch lighting on/off |
| 5 | LEARN ALL – buttons 1 SBS, 2 partial opening, 3 opening only, 4 lighting |
Lighting switched on by remote control is switched off using the remote control.
Deleting a stored button
- Enter RADIO MENU.
- Hold DOWN-RADIO until the KEY LED lights up, then release the button.
- Within seven seconds, hold the remote-control button you want to delete until the KEY LED starts flashing, then release it.
- Confirm deletion by pressing DOWN-RADIO. A long flash of the KEY LED confirms deletion.
If the remote was stored using LEARN ALL, this procedure deletes all functions assigned to it.
Deleting the entire remote-control memory
- In RADIO MENU, hold DOWN-RADIO: the KEY LED lights up after about three seconds; keep holding until it goes out, then release the button.
- The LED starts flashing slowly. At the third flash briefly press DOWN-RADIO.
- A long flash of the KEY LED confirms that all remote controls have been deleted.
Adding a new remote using one already stored
- Near the control unit, hold a button on the new remote for at least five seconds.
- On the remote control already stored, hold the button for the desired function for at least three seconds. After the first step is completed correctly, the gate will not move during this step.
- Again, hold the same button on the new remote control for at least three seconds.
- Again, hold the same button on the old remote control for at least three seconds. Successful storage is confirmed when the copied command is executed.
Restoring factory settings
Resetting settings via MOTOR SETUP and deleting remote controls are separate procedures. If the motor type is not changed, the manual specifies restoring the factory settings without needing to relearn the travel path. If you change the type, the travel path must be relearned.
- Hold MENU until ADV appears. Use UP/DOWN-RADIO to select MOTOR SETUP.
- Hold MENU until the motor type number starts flashing.
- Select value 3 for KEY Turbo S TUS11324 according to the corresponding motor list for the control board.
- Hold MENU during the countdown 50 → 0. Release when DONE appears. Exit the menu by briefly pressing MENU or after seven seconds of inactivity.
Display, input and warning light diagnostics
First, remove the cause. The error message will then clear after a complete movement to the relevant limit switch, or by briefly pressing MENU without moving the gate. Only work on the mechanism and terminal blocks after disconnecting the power supply.
| Message | Meaning / check |
|---|---|
| LEARN TO DO | The travel path has not been learned. |
| READY | Gate closed; control unit restarted. |
| OPEN ING / CLOSE ING | Opening / closing in progress. |
| STOP OPEN / STOP CLOSE | Movement stopped while opening / closing. |
| FOTO1 / FOTO2 | PH1 / PH2 input active; check the photocell, obstruction and wiring. |
| ALIGN MENT | Position realignment in progress. |
| OPEN | Gate open with no active closing timer. |
| PAR TIAL / PART OPEN | Partial opening / stopped in the partially open position. |
| TIME CLOSE / TIME PART | Closing timer from fully / partially open; the remaining time is displayed during the final ten seconds. |
| LEARN STOP | Learning stopped by a safety device being triggered or by an intentional stop. |
| LEARN OPEN1 / LEARN CLOS1 | Learning the opening / closing travel path. |
| SLOW OPEN1 / SLOW CLOS1 | Determining the slowdown points automatically. |
| OVER LOAD1 | Motor current has risen sharply; check for an obstruction and mechanical resistance. |
| EDGE | Safety edge active or incorrectly wired. |
| FOTO TEST | Photocell or safety edge test failed; check operation and wiring. |
| Warning light / LED KEY flashing | Event |
|---|---|
| 2 fast flashes + pause + 1 | Automatic learning |
| 4 fast flashes + pause, three times | Obstruction detected |
| 2 fast flashes + pause, three times | PH1/PH2 photocell triggered |
| 5 fast flashes + pause, three times | Safety edge triggered |
| 3 fast flashes + pause, three times | Photocell or safety edge test failure |
| 6 fast flashes + pause, three times | Short circuit or overload on the FLASH, IND/ELEC or LED output |
Press UP repeatedly to display the number of complete cycles (NCY), the motor's instantaneous current in mA, and the control board type/firmware version/serial number. Red LEDs indicate safety inputs and limit switches; green LEDs indicate control inputs. A flashing LED after changing a safety DIP switch requires the corresponding confirmation; do not disable functioning safety devices as a way to resolve a fault.
Checks and maintenance
Before handover, test all components, photocells, safety edges, commands, stops and manual release, and measure impact forces. Provide the manual, safety instructions, documentation and maintenance schedule. For normal domestic use, the manufacturer recommends an inspection every six months; adjust the interval according to usage.
With the system safely shut down and released, the user may clean the photocell lenses with a slightly damp cloth and remove leaves or stones. After repairs or changes to the settings, carry out functional and safety tests. In the event of a fault, disconnect the power and call a service technician; faulty safety devices must be repaired without delay. Keep the key and remote controls out of children's reach.
Technical specifications of the KEY Turbo S TUS11324
| Specification | Value |
|---|---|
| Brand: | KEY Automation |
| Model: | Turbo S (TUS11324) |
| Control unit: | CT-10324 |
| Operator power supply: | 230 V |
| Motor power supply: | 24V |
| Limit stop: | electromechanical switch |
| Power consumption: | 300 W |
| Motor current: | 1.3 A |
| Pinion module: | M4 |
| Max. load: | 1100 kg |
| Speed: | 20 cm/s |
| Protection rating: | IP44 |
| Operating temperature: | -20 / +55 °C |
| Torque | 38 Nm |
| Dimensions (L × W × H) | 335 × 190 × 280 mm |
| Operator weight | 8.8 kg |
| Max. cycles/h | 50 under the reference conditions stated above |
| Noise | ≤ 70 dB(A) |
| Integrated receiver | 433.92 MHz OOK; 150 transmitters |