Hormann LineaMatic - standalone operator for sliding gates up to 300kg/6m, 4511323 (A)


Product availability: In stock

We normally dispatch goods within 24 hours.


Hormann LineaMatic - standalone operator for sliding gates up to 300kg/6m, 4511323 (A) Hormann LineaMatic - standalone operator for sliding gates up to 300kg/6m, 4511323 (A)
HOR-LINEAMATIC
In stock
€321.40 excluding VAT
€395.32 including VAT

 pcs
Weight
15 kg

Description of Hormann LineaMatic - standalone operator for sliding gates up to 300kg/6m, 4511323 (A)

The operator is designed for sliding gates with a passage length of 6m/300kg. The closed end position is detected by a magnet and a REED switch. The travel and forces are learned during commissioning. The operator is non-reversible.

The operator includes a built-in control unit with an integrated bidirectional receiver for operating it with remote controls. The advantage of the bidirectional receiver is that you can check the status of the open gate directly on the remote control.

Hörmann LineaMatic 4511323 is an operator for sliding gates up to 6 m wide and 2 m high. For ground-running gates, the limit is 300 kg, and for cantilever gates 250 kg. The infill and local wind loads must be assessed together with the gate's mechanical resistance.

Before opening the housing, disconnect the mains and any backup battery. Secure the gate leaf against unintended movement, and protect both the main and secondary closing edges as well as the rack-and-pinion engagement area.

Installation, wiring and setup
Kit and standalone operatorAccessoriesInstallation
WiringManual releaseControl board
Terminals and power supplyPhotocells and safetyInitial startup
Travel learningProgrammingRemote controls
Reset and memoryDiagnosticsMaintenance
Technical specificationsInstallation manual (PDF)

Standalone LineaMatic operator and related kits

Base model variants
VariantSelection
Standalone LineaMatic 4511323 (A)An operator for replacing or adding to an existing setup. Accessories are selected separately.
LineaMatic 4511323 kit (D)An alternative kit offer. Check the contents on the product page for the specific kit.
LineaMatic 4511323 kit (B)Another kit variant; do not assume its contents based solely on the same motor.

Accessories and connections

Specific examples shown in the diagrams include EL301, EL31, SLK, HOR 1, UAP 1/UAP 1-300 and HNA Outdoor. These are not included with the standalone operator. Hörmann SK-SET LineaMatic 437989 is a separately offered accessory. Always check the wiring against the labels on the supplied device.

Installing LineaMatic

Preparing the gate and foundation

The gate must move easily and evenly by hand, have stable guidance, and be mechanically secured against running off the track. Disable locks and mechanical locking devices that prevent motorized movement. The operator is not a substitute for repairing a gate that is difficult to move or damaged.

Select the foundation according to whether installation is with or without a base plate. For an installation without closing-edge protection, the section shows the basic minimum dimensions 345 × 280 mm; the specific distances 175 mm without a plate or 200 mm with a plate and orientation relative to the gate must follow the complete illustration. Closing-edge protection requires a larger foundation, as shown in the relevant PDF drawing. Choose a frost-free depth according to the installation site; the 80 cm value in the manual is an example for Germany. The concrete must be sufficiently cured before installation; for a base plate, the manufacturer requires compacted concrete of at least B25/C25.

LineaMatic foundation with and without a base plate – both orientations
LineaMatic foundation with and without a base plate – both orientations

Anchoring and installation height

The operator position depends on the specific rack. Dimension A shown in the drawing is not interchangeable between different racks.

Installation dimension for the original rack
Rack referenceDimension A
436444124–136 mm
438759126–138 mm
438631125–129 mm
438632129–133 mm

Installation heights and dimension A for each rack
Installation heights and dimension A for each rack

For anchor bolts, use a drilling template and drill holes Ø 12 mm, 80 mm deep. For heavy-duty anchors and a base plate, the holes are Ø 10 mm, 105 mm deep; the drawing specifies a tightening torque of 45 Nm for the anchoring shown. Protect the operator from dust and swarf. The installer must confirm the load-bearing capacity of the actual substrate and the suitability of the supplied anchors.

LineaMatic anchor bolts – Ø 12 mm holes
LineaMatic anchor bolts – Ø 12 mm holes
Installation through the base plate – Ø 10 mm holes and anchoring dimensions
Installation through the base plate – Ø 10 mm holes and anchoring dimensions

Fit the conduit seals and route the cables into the housing from below. Position the operator level and secure it firmly. When the cover is open, protect the electronics from moisture; after installation, seal the housing against water and insects.

Positioning the LineaMatic housing and sealing the cable glands
Positioning the LineaMatic housing and sealing the cable glands

Rack and end-position magnet

The operator must be disengaged when installing the rack. The joints between individual sections must align smoothly without any offset. After installation, align the rack, pinion and operator housing with one another; follow the dimensions in the relevant illustration, not values taken from another brand. Incorrect meshing can cause unintended reversal.

Fastening and aligning the LineaMatic rack
Fastening and aligning the LineaMatic rack

The closed end position is detected by a magnet and REED switch. Move the gate manually to the closed position, pre-mount the magnetic slide in the middle position, then secure it offset by approximately 20 mm from the reed switch as shown in the illustration. Check the final position and fine-tune it during the learning run.

Mains connection, circuit board holder and magnet position at the 20 mm dimension
Mains connection, circuit board holder and magnet position at the 20 mm dimension

Wiring and separation of voltages

Wiring for the configuration described
CircuitRequirement
Mains230/240 V AC; 3 × 1.5 mm² supply cable; use a suitable underground cable as specified in the instructions. Separate conduit.
AccessoriesRoute 24 V circuits separately from the mains. Terminals for 0.5–2.5 mm² conductors.
External push buttonCable run: 30 m max.
HALT and safety circuits shown in the diagramsCable run: 10 m max., depending on the specific wiring diagram.
Extending underground cablesUse a suitable IP65-rated junction box; do not leave a joint unprotected underground.

Manual release and re-engagement

  1. Disconnect the mains and any HNA Outdoor unit. Secure the gate against uncontrolled movement.
  2. Open the cover and turn the release mechanism to the released position as shown in the diagram. The motor and pinion will lower into the housing; press them down gently if necessary.
  3. Move the gate manually and under control. Keep your hands clear of the rack and pinion.
  4. To re-engage the drive, turn the mechanism to the locked position while lifting the motor slightly. The gate must re-engage with the drive before reaching the limit switch.
  5. Replace the cover. When power is restored, a reference run towards the closed position may follow; keep the area clear and supervise the gate.
Opening the LineaMatic operator and manually releasing it
Opening the LineaMatic operator and manually releasing it
Re-engaging the drive – lift the motor slightly while turning the mechanism
Re-engaging the drive – lift the motor slightly while turning the mechanism

Orientation of the control board

The diagram is oriented with the buttons T_AUF, P and T_ZU at the top and the long row of terminals at the bottom. BUS is at the top by the buttons, REED and HALT on the left, SE3 on the raised section above SE1/SE2 at the bottom. MOTOR, SNT and the AKKU connection are on the right. Use the connector labels to distinguish signal, motor and power circuits.

LineaMatic board – exact terminal and connector labels
LineaMatic board – exact terminal and connector labels

Power supply, polarity and control terminals

LineaMatic terminals and distinguishing power connections from control signals
Terminal / connectorFunction and limit
Mains section L / N and housing PE230/240 V AC mains, 50/60 Hz; L is live, N is neutral and PE is protective earth. AC has no positive or negative polarity. Connect the supply to the mains section, not to the signal terminals.
5 / 205 = positive (+24 V DC), 20 = 0 V (−). Maximum total current draw of accessories: 250 mA; include all connected devices in the calculation.
24 V=: 24 V / 0 VSeparately labelled DC output: 24 V = +, 0 V = −. For example, use it for a 24 V light as shown in the wiring diagram; it is not a 230 V output.
21 / 20NO, voltage-free pulse or contact switching to 0 V. Push buttons can be wired in parallel; the contact itself has no +/− polarity.
23 / 20NO, voltage-free partial-opening command; 23 is the signal, 20 is the common 0 V, not a power-supply pair.
HALT 12 / 13NC, voltage-free STOP; 13 = 0 V, 12 is the input. When installing the STOP, remove the original 12–13 jumper and connect an NC contact.
REEDReed-switch limit sensor as supplied in the original configuration; do not connect an external voltage.
BUSSystem accessories with the matching connector. This is not a universal +/− output for arbitrary devices.
MOTOR / SNT / AKKUMotor, mains section and specified emergency battery. Use the original connectors and observe the marked polarity; disconnect the battery as well before working on the unit.

Applying external voltage to the control inputs can destroy the electronics. Do not connect 230 V to 21/23/HALT or SE. HALT is not a monitored PLc-level safety input; do not confuse it with the SE safety device.

REED, external receiver and NO push buttons 20–21 / 20–23
REED, external receiver and NO push buttons 20–21 / 20–23
NC stop circuit HALT on 12–13
NC stop circuit HALT on 12–13

SLK beacon and Option relay

Relay Option has voltage-free contacts .5 common, .8 NO, .6 NC. For a 24 V light, the wiring diagram uses 24 V (+) → .5, .8 → light, light return → 0 V (−). For a polarity-sensitive light, connect its positive input to the switched supply from .8 and its negative input to 0 V. For this 24 V light, the manufacturer specifies max. 7 W; also observe the total accessory limit; the 7 W rating does not increase it. The internal relay function is set in menu 31.

Original wiring diagram for a 24 V light via the Option contacts and 24V= output
Original wiring diagram for a 24 V light via the Option contacts and 24 V= output

A 230 V light has its own external mains supply; the manufacturer's wiring diagram specifies a maximum of 500 W. Mains conductors must have additional insulation all the way to the connection. Follow the complete PDF when wiring; 230 V must not enter the low-voltage circuits.

Photocells and SE1/SE2/SE3 safety inputs

Power and signal terminals for safety circuits
InputTerminals and original response
SE15 = +24 V DC; 20 = 0 V (−); 18 = test, 71 = signal. Active during closing; briefly reverses direction.
SE25 = +24 V DC; 20 = 0 V (−); 18 = test, 72 = signal. Active during opening; briefly reverses direction.
SE35 = +24 V DC; 20 = 0 V (−); 18 = test, 73 = signal. Acts during closing, briefly reverses.

SE1 and SE2 support dynamic two-wire photo eyes, tested or untested three-wire photo eyes, an 8k2 resistive safety edge, and designated edge protection. Photo eyes are listed here for SE3; do not use the SE1/SE2 resistive edge wiring for SE3. Two photo eyes on one circuit require an LSE2 expander. According to the instructions, untested safety devices are permitted only for property protection.

EL301 – exact wiring according to the original diagram

EL301 is a dynamic two-wire set with a current draw of 35 mA as shown in the illustration. For SE1, connect TX 0 V and RX 0 V → 20, the marked terminal TX → 71 and the marked terminal RX → 71. For SE2, replace 71 with terminal 72; for SE3, use terminal 73. Terminal 5 and test terminal 18 are not used in this specific EL301 diagram. The TX/RX markings are system terminals; do not assign your own +24 V supply or polarity based on other photo eyes.

SE1 – original wiring for EL301, EL31, 8k2 and contact photo eye
SE1 – original wiring for EL301, EL31, 8k2 and contact photo eye

For EL31 the diagram shows receiver RX: 20 → 20 (0 V), 18 → 18 (test), 71/72/73 → 71 (signal according to the selected SE), 5 → 5 (+24 V). The transmitter TX has 20 → 20 (0 V), 5 → 5 (+24 V). The original color markings are GN/WH/BN; however, the actual terminal markings and the instructions for the supplied photo eye take precedence. For a different contact with its own power supply, use its own wiring diagram; a volt-free NC contact must not be confused with a +/− power supply.

SE2 – separate wiring, signal 72 and protection during opening
SE2 – separate wiring, signal 72 and protection during opening
SE3 – separate photo-eye wiring with signal 73
SE3 – separate photo-eye wiring with signal 73

Connect all safety devices before the learning process. After adding or changing safety devices, run the learning process again menu 10 and perform functional tests. After changing the direction of operation, reversing, speed or force in the advanced menus, repeat the safety tests.

Optional modules and external receiver

Examples of optional accessories
DeviceWiring / function
External wired receiverGN → 20 (0 V); BN → 5 (+24 V DC); WH → 21 (impulse); YE → 23 (partial opening). HEI3 BiSecur has a matching connector; ESEI BiSecur connects to the BUS.
HOR1 / UAP1 / UAP1-300Matching BUS connectors as shown in the illustration; HOR1 draws 25 mA, UAP1 45 mA. External relay functions in menu 30.
HNA OutdoorUse the designated AKKU connection; switches over automatically in the event of a mains failure. Unplug the connector before servicing; disconnecting the mains does not disconnect the entire operator.

Original connections for HOR1, UAP1 and the emergency battery
Original connections for HOR1, UAP1 and the emergency battery

Initial startup and selecting type 01

Safety devices must be connected, optical paths clear, the gate mechanically sound, and the area closed to people. During the learning process, the end positions, forces and connected safety devices are stored. The direction is determined during learning; after successful commissioning, it can only be changed by performing a factory reset and learning again.

  1. Switch on the power. The display first shows 8.8., then U. The type is preset on delivery; after a factory reset, use the T_AUF button to select 01 for the standard LineaMatic. Type 02/P or 03/H does not increase this operator's load capacity.
  2. Press and hold P. After the type and LA are displayed, the control unit enters end-position learning mode.
  3. Disengage the operator, open the gate by about 1 m, then re-engage it. Press and hold T_ZU; the gate must move towards the closed position. If it moves in the opposite direction, release the button briefly, then press and hold T_ZU again, following the manufacturer's procedure.
  4. When the gate stops at the magnetic limit switch, release the button. If the closed position is incorrect, adjust the magnetic slide and repeat the test.
  5. Press and hold T_AUF until the desired open position is reached, release it, make fine adjustments with T_AUF/T_ZU, then save by pressing P.
  6. To learn the forces, briefly press T_ZU and let the gate close; then press T_AUF and let it open fully. When complete, 11 flashes to indicate radio control learning. A safety device must not be activated while the forces are being learned.
  7. Store the desired transmitters or exit radio control learning mode. Check the safety devices and forces across the entire gate, refit the covers, and show the user how to disengage the operator manually.
Initial LineaMatic learning – type 01, closed and open positions
Initial LineaMatic learning – type 01, closed and open positions
Force learning – fully close and open
Force learning – fully close and open

Relearning after changing the gate or safety devices

Menu 10 erases the previous travel path and force settings. Once activated, it cannot be exited early; the learning process must be completed. Use after changing end positions or mechanics, servicing, or adding photo eyes or a safety edge. There is no standard time limit.

  1. Open the gate by about 1 m, select menu 10, and hold P for 5 seconds.
  2. Press T_ZU and let the gate travel to the closing limit switch.
  3. Press and hold T_AUF until the desired open position is reached, adjust as needed, and confirm with P.
  4. Start T_ZU to close fully and T_AUF to open fully so the forces are learned again.
  5. When finished, check all safety devices and operating settings.
Menu 10 – relearning the end positions
Menu 10 – relearning the end positions

Programming via the display

To enter, press and hold P for approximately 5 seconds, until 00 is displayed. T_AUF/T_ZU selects the menu or parameter. For a standalone function, hold P for 2 seconds; for a menu with parameters, press P briefly first, select the parameter, then hold P for 2 seconds to save. A dot next to the number indicates the active setting. Menu 00 followed by a brief press of P exits programming; the standard timeout is 60 seconds, or 25 seconds during radio control learning. Do not assume a new parameter has been saved unless it has been confirmed.

Entering, selecting and confirming the public LineaMatic menus
Entering, selecting and confirming the public LineaMatic menus

Only the factory-designated presets for the standard LineaMatic are shown in bold. The documented public menus are listed; after changing service settings for force, speed or reversing limits, repeat the safety tests.

Public menus for the standard LineaMatic
Menu / functionOptions and conditions
00 – Enter / exitReturn to operation via 00 and a brief press of P.
01 – LineaMatic type01 – standard LineaMatic. For initial commissioning only or after a factory reset; 02 and 03 are for other models.
10 – RelearningHold P for 5 s; erases the travel path/forces and requires the learning process to be completed again.
11 – Radio – impulseLearn the code for the main sequential command.
12 – Radio – lightLearn the light function with the appropriate external relay/module.
13 – Radio – partial openingLearn the partial-opening code.
14 – Radio – openSeparate opening direction: open–STOP–open.
15 – Radio – closeSeparate closing direction: close–STOP–close.
19 – Delete all radio codesHold P for 5 s; deletes all functions and all transmitters.
20 – Internal light offDisables the movement-activated light; automatically selects 31/07.
21 – Internal light 30 sLight remains on after movement ends; activates 31/00.
22 – Internal light 60 sDefault 60 s run-on time; activates 31/00.
23 – Internal light 120 sLight remains on after movement ends; activates 31/00.
24 – Internal light 180 sLight remains on after movement ends; activates 31/00.
25 – External light offAn external light command will not switch it on.
26 – External light 5 minDefault time: 5 min. The light is activated by an external command.
27 – External light 10 minExternal lighting duration.
28 – External light ON/OFFPermanent on/off switching via HOR1 or UAP1 relay 3; do not combine with 25.
30 – External relay functionHOR1/UAP1/UAP1-300; parameters below.
31 – Internal relay functionOption contacts; parameters below.
32 – Pre-warningOptions 00–10 as shown in the table below.
34 – Automatic closingRequires a connected and taught-in photocell; see settings below.
35 – Automatic closing after partial openingRequires a taught-in photocell; see settings below.
36 – Partial opening positionHold P for 5 s, use T_AUF/T_ZU to set the position, then press P to save. Default: 900 mm; the controller rejects a position that is too close.

Menus 30 and 31 – relay parameters

Relay function parameters
ParameterDescription
00Lighting function: external for 30, internal for 31. Menu 30/00 activates 26; 31/00 activates 22.
01 / 02 / 03Open / closed / partially open position indication.
04Pulse signal when an opening command is given; in menu 30, also when partially open, for the external relay.
05Fault indication.
06Continuous signal during start-up/pre-warning.
07Default flashing during start-up/pre-warning.
08Relay energised during movement and de-energised at the end positions.
09Service interval indication In.
10Flashing during start-up/pre-warning only when closing.

For parameters 01–10, menu 25 is activated for the external relay and menu 20 for the internal relay. Pre-warning is effective only when menu 32 is enabled. Therefore, always check a relay change together with the menu linked to it automatically.

Menus 32, 34 and 35 – time options

Pre-warning
Menu 32 parameterTime / function
00off
011 s
022 s
033 s
044 s
055 s
0610 s
0715 s
0820 s
0930 s
1060 s

Wait time after fully opening
Menu 34 parameterTime / function
00off
015 s
0210 s
0430 s
0560 s
0690 s
07120 s
08180 s
09240 s
10300 s

Wait time after partial opening
Menu 35 parameterTime / function
00off
01same as 34
025 min
0315 min
0430 min
0545 min
0660 min
0790 min
08120 min
09180 min
10240 min

Activate automation 34/35 only after teaching the photocell. When they are enabled, the pre-warning 32/02 is automatically set to 2 seconds. During automatic closing, a new command will stop the gate. Set partial opening in menu 36; if it is too close to the closed position, the unit will display error 1 and use the minimum permitted position.

Storing remote controls

The integrated receiver stores up to 150 radio codes, divided among the functions. When capacity is exceeded, the oldest codes are deleted. If you store the same code for another function, its original assignment is removed. A code is not necessarily an entire transmitter with all its buttons.

  1. The gate must be stationary, with no active pre-warning or automatic closing time.
  2. Select 11 for an impulse or 12/13/14/15 for the desired alternative function, then briefly press P. The number flashes.
  3. Hold down the button on a compatible transmitter in code-transmission mode; when BiSecur is displayed, the red/blue LED alternates after approximately 5 seconds.
  4. When the menu number on the operator flashes rapidly, the code has been recognized. Release the button. Another code can be added within 25 seconds.
  5. Briefly press P to interrupt programming; use 00 and P to return to operation. Then test each stored function with the area secured.
Teaching a BiSecur code via menu 11
Teaching a BiSecur code via menu 11

Status feedback requires a suitable two-way transmitter with a position-check function; the 868 MHz frequency alone does not confirm this capability. Not every transmitter has a status button or uses the same battery procedure. For code sharing and resetting a specific transmitter, refer to its own manual.

Connecting an external receiver retrospectively

When connecting an external radio receiver retrospectively, the manufacturer requires you to delete the radio codes from the integrated receiver via menu 19. This will delete all transmitters and functions stored in it; before proceeding, make a note of the remotes in use and their assignments. Then teach the codes to the external receiver according to its own manual. The external receiver's antenna wire must not be placed next to metal objects.

Clearing the radio memory and factory reset

Menu 19 – delete all codes

Select 19 and hold P for 5 seconds. 19 first flashes slowly for 5 seconds, then rapidly for approximately 3 seconds; a steady 19. confirms deletion. All transmitters and all functions will be deleted. This procedure does not support deleting a single button or function individually.

Resetting the operator to factory settings

A factory reset restores the settings and deletes the learned travel paths and forces; radio codes are retained. Menu 10 is only for relearning the travel path/forces; menu 19 separately deletes the radio codes. Do not confuse these three procedures.

  1. Disconnect the mains supply and emergency battery as shown in the illustration. Secure the gate against movement.
  2. Hold down P and restore the mains supply.
  3. Keep holding P while 8.8. and C are displayed, until U appears; then release it.
  4. Select the correct type 01 and repeat the entire commissioning procedure. Also check the retained remotes, safety devices, times, and forces.
LineaMatic factory reset – disconnecting the mains supply/battery and holding P
LineaMatic factory reset – disconnecting the mains supply/battery and holding P

Reference run after disengagement or a power failure

A reference run may be required if the position is unknown after a power failure or after the force limit has been triggered three times. The next impulse will start it in the closing direction only, at reduced speed and without force limitation. The area must be secured; if it is not protected by a photocell or other device, the run may only be carried out with the gate in view. After manual disengagement without a power failure, once the power supply has been secured, disconnect it once more so that the new reference run is performed as described in the manual.

Display diagnostics

Error messages and basic statuses
DisplayMeaning / procedure
UThe operator has not been taught; commission it.
8.8.Startup or loading of radio codes; this is not necessarily an error.
1 s with a flashing dotCannot set the reversing limit or partial position; check for obstructions and clearance from the closed position.
2.1 / 2.2 / 2.3SE1 / SE2 / SE3 protection: obstruction, misalignment, guide or device damage.
3 / 5Force limit during closing/opening; remove the obstruction and check the mechanical travel rather than automatically increasing the force.
4HALT12–13 interrupted; check the NC circuit and wiring.
6System error or travel time limit; check the reset and relearn the system. 6
System error or travel time limit; check the reset and relearn the system; if the operator is faulty, arrange for it to be repaired or replaced.Communication error on the expansion board; check the wiring, connectors, and module.
8Invalid input or control command; check the selected value.
9Triggered/faulty tested safety device or 8k2; remove the obstruction and check the safety device.
13 / 17Undervoltage / voltage error; check the power supply and battery.
CUnknown reference point; secure the area and perform a reference run.
InThe service interval has elapsed; have the system inspected.

Original symbols for operating statuses and display indicators
Original symbols for operating statuses and display indicators

Maintenance and safe handover

The manufacturer describes the operator as maintenance-free, but the entire gate requires regular inspection. Check safety and protective functions monthly, and check 8k2 resistance edges and untested safety devices every six months according to the manual. Check for smooth operation, secure rack fastening, guide alignment, cable damage, clean photocells, and correct disengagement function. Correct any defects without delay.

Before maintenance, disconnect all power sources and prevent them from being switched on again. After installation and any changes, check the effectiveness of the safety devices, reversing, and operating forces. Train the user, hand over the manuals, and attach the warning label visibly to the gate. Children must not play in the movement area; pass through only after the gate has come to a complete stop.

Technical specifications of Hörmann LineaMatic 4511323

Specifications of the basic model and power circuits
ParameterValue
Model / type selectionBasic LineaMatic /01
Maximum gate width / height6000 mm /2000 mm
Max. weight – ground-supported / cantilevered300 kg /250 kg
Mains supply230/240 V AC,50/60 Hz; permitted range 170–260 V AC.
Control voltage24 V/37 V DC, switchable internal control; not a universal output for accessories.
Accessory power supply24 V DC; 5=plus, 20=0 V; total max. 250 mA.
Radio frequency / memory868 MHz / up to 150 radio codes
Protection rating / temperatureIP44 / −20 to +60 °C
Maximum humidity93%, non-condensing
Standby power consumptionLess than 0.5 W
End positionsMagnetic REED switch sensor and electronically learned positions/forces.
Cycles per day/hourAs stated on the rating plate.
HousingCast aluminium and glass-fibre-reinforced plastic.

Original dimensioned drawing of LineaMatic and related version
Original dimensioned drawing of LineaMatic and related version

The dimensioned drawing shows the housing 193 × 253 × 256 mm. When mounted on a floor plate, the overall height can be adjusted up to 327 mm; the plate shown has a footprint of 260 × 295 mm. Choose the actual mounting height relative to the rack based on dimension A, not just the external dimensions of the cover.

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about Hormann LineaMatic - standalone operator for sliding gates up to 300kg/6m, 4511323 (A)

Product: Hormann LineaMatic - standalone operator for sliding gates up to 300kg/6m, 4511323 (A)
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.