Hormann LineaMatic - standalone operator for sliding gates up to 300kg/6m, 4511323 (A)
| Product availability: | In stock | We normally dispatch goods within 24 hours. |
|---|
In stock
€395.32 including VAT
| Weight |
|---|
| 15 kg |
Description of Hormann LineaMatic - standalone operator for sliding gates up to 300kg/6m, 4511323 (A)
The operator is designed for sliding gates with a passage length of 6m/300kg. The closed end position is detected by a magnet and a REED switch. The travel and forces are learned during commissioning. The operator is non-reversible.
The operator includes a built-in control unit with an integrated bidirectional receiver for operating it with remote controls. The advantage of the bidirectional receiver is that you can check the status of the open gate directly on the remote control.
Hörmann LineaMatic 4511323 is an operator for sliding gates up to 6 m wide and 2 m high. For ground-running gates, the limit is 300 kg, and for cantilever gates 250 kg. The infill and local wind loads must be assessed together with the gate's mechanical resistance.
Before opening the housing, disconnect the mains and any backup battery. Secure the gate leaf against unintended movement, and protect both the main and secondary closing edges as well as the rack-and-pinion engagement area.
Standalone LineaMatic operator and related kits
| Variant | Selection |
|---|---|
| Standalone LineaMatic 4511323 (A) | An operator for replacing or adding to an existing setup. Accessories are selected separately. |
| LineaMatic 4511323 kit (D) | An alternative kit offer. Check the contents on the product page for the specific kit. |
| LineaMatic 4511323 kit (B) | Another kit variant; do not assume its contents based solely on the same motor. |
Accessories and connections
Specific examples shown in the diagrams include EL301, EL31, SLK, HOR 1, UAP 1/UAP 1-300 and HNA Outdoor. These are not included with the standalone operator. Hörmann SK-SET LineaMatic 437989 is a separately offered accessory. Always check the wiring against the labels on the supplied device.
Installing LineaMatic
Preparing the gate and foundation
The gate must move easily and evenly by hand, have stable guidance, and be mechanically secured against running off the track. Disable locks and mechanical locking devices that prevent motorized movement. The operator is not a substitute for repairing a gate that is difficult to move or damaged.
Select the foundation according to whether installation is with or without a base plate. For an installation without closing-edge protection, the section shows the basic minimum dimensions 345 × 280 mm; the specific distances 175 mm without a plate or 200 mm with a plate and orientation relative to the gate must follow the complete illustration. Closing-edge protection requires a larger foundation, as shown in the relevant PDF drawing. Choose a frost-free depth according to the installation site; the 80 cm value in the manual is an example for Germany. The concrete must be sufficiently cured before installation; for a base plate, the manufacturer requires compacted concrete of at least B25/C25.

Anchoring and installation height
The operator position depends on the specific rack. Dimension A shown in the drawing is not interchangeable between different racks.
| Rack reference | Dimension A |
|---|---|
| 436444 | 124–136 mm |
| 438759 | 126–138 mm |
| 438631 | 125–129 mm |
| 438632 | 129–133 mm |

For anchor bolts, use a drilling template and drill holes Ø 12 mm, 80 mm deep. For heavy-duty anchors and a base plate, the holes are Ø 10 mm, 105 mm deep; the drawing specifies a tightening torque of 45 Nm for the anchoring shown. Protect the operator from dust and swarf. The installer must confirm the load-bearing capacity of the actual substrate and the suitability of the supplied anchors.


Fit the conduit seals and route the cables into the housing from below. Position the operator level and secure it firmly. When the cover is open, protect the electronics from moisture; after installation, seal the housing against water and insects.

Rack and end-position magnet
The operator must be disengaged when installing the rack. The joints between individual sections must align smoothly without any offset. After installation, align the rack, pinion and operator housing with one another; follow the dimensions in the relevant illustration, not values taken from another brand. Incorrect meshing can cause unintended reversal.

The closed end position is detected by a magnet and REED switch. Move the gate manually to the closed position, pre-mount the magnetic slide in the middle position, then secure it offset by approximately 20 mm from the reed switch as shown in the illustration. Check the final position and fine-tune it during the learning run.

Wiring and separation of voltages
| Circuit | Requirement |
|---|---|
| Mains | 230/240 V AC; 3 × 1.5 mm² supply cable; use a suitable underground cable as specified in the instructions. Separate conduit. |
| Accessories | Route 24 V circuits separately from the mains. Terminals for 0.5–2.5 mm² conductors. |
| External push button | Cable run: 30 m max. |
| HALT and safety circuits shown in the diagrams | Cable run: 10 m max., depending on the specific wiring diagram. |
| Extending underground cables | Use a suitable IP65-rated junction box; do not leave a joint unprotected underground. |
Manual release and re-engagement
- Disconnect the mains and any HNA Outdoor unit. Secure the gate against uncontrolled movement.
- Open the cover and turn the release mechanism to the released position as shown in the diagram. The motor and pinion will lower into the housing; press them down gently if necessary.
- Move the gate manually and under control. Keep your hands clear of the rack and pinion.
- To re-engage the drive, turn the mechanism to the locked position while lifting the motor slightly. The gate must re-engage with the drive before reaching the limit switch.
- Replace the cover. When power is restored, a reference run towards the closed position may follow; keep the area clear and supervise the gate.


Orientation of the control board
The diagram is oriented with the buttons T_AUF, P and T_ZU at the top and the long row of terminals at the bottom. BUS is at the top by the buttons, REED and HALT on the left, SE3 on the raised section above SE1/SE2 at the bottom. MOTOR, SNT and the AKKU connection are on the right. Use the connector labels to distinguish signal, motor and power circuits.

Power supply, polarity and control terminals
| Terminal / connector | Function and limit |
|---|---|
| Mains section L / N and housing PE | 230/240 V AC mains, 50/60 Hz; L is live, N is neutral and PE is protective earth. AC has no positive or negative polarity. Connect the supply to the mains section, not to the signal terminals. |
| 5 / 20 | 5 = positive (+24 V DC), 20 = 0 V (−). Maximum total current draw of accessories: 250 mA; include all connected devices in the calculation. |
| 24 V=: 24 V / 0 V | Separately labelled DC output: 24 V = +, 0 V = −. For example, use it for a 24 V light as shown in the wiring diagram; it is not a 230 V output. |
| 21 / 20 | NO, voltage-free pulse or contact switching to 0 V. Push buttons can be wired in parallel; the contact itself has no +/− polarity. |
| 23 / 20 | NO, voltage-free partial-opening command; 23 is the signal, 20 is the common 0 V, not a power-supply pair. |
| HALT 12 / 13 | NC, voltage-free STOP; 13 = 0 V, 12 is the input. When installing the STOP, remove the original 12–13 jumper and connect an NC contact. |
| REED | Reed-switch limit sensor as supplied in the original configuration; do not connect an external voltage. |
| BUS | System accessories with the matching connector. This is not a universal +/− output for arbitrary devices. |
| MOTOR / SNT / AKKU | Motor, mains section and specified emergency battery. Use the original connectors and observe the marked polarity; disconnect the battery as well before working on the unit. |
Applying external voltage to the control inputs can destroy the electronics. Do not connect 230 V to 21/23/HALT or SE. HALT is not a monitored PLc-level safety input; do not confuse it with the SE safety device.


SLK beacon and Option relay
Relay Option has voltage-free contacts .5 common, .8 NO, .6 NC. For a 24 V light, the wiring diagram uses 24 V (+) → .5, .8 → light, light return → 0 V (−). For a polarity-sensitive light, connect its positive input to the switched supply from .8 and its negative input to 0 V. For this 24 V light, the manufacturer specifies max. 7 W; also observe the total accessory limit; the 7 W rating does not increase it. The internal relay function is set in menu 31.

A 230 V light has its own external mains supply; the manufacturer's wiring diagram specifies a maximum of 500 W. Mains conductors must have additional insulation all the way to the connection. Follow the complete PDF when wiring; 230 V must not enter the low-voltage circuits.
Photocells and SE1/SE2/SE3 safety inputs
| Input | Terminals and original response |
|---|---|
| SE1 | 5 = +24 V DC; 20 = 0 V (−); 18 = test, 71 = signal. Active during closing; briefly reverses direction. |
| SE2 | 5 = +24 V DC; 20 = 0 V (−); 18 = test, 72 = signal. Active during opening; briefly reverses direction. |
| SE3 | 5 = +24 V DC; 20 = 0 V (−); 18 = test, 73 = signal. Acts during closing, briefly reverses. |
SE1 and SE2 support dynamic two-wire photo eyes, tested or untested three-wire photo eyes, an 8k2 resistive safety edge, and designated edge protection. Photo eyes are listed here for SE3; do not use the SE1/SE2 resistive edge wiring for SE3. Two photo eyes on one circuit require an LSE2 expander. According to the instructions, untested safety devices are permitted only for property protection.
EL301 – exact wiring according to the original diagram
EL301 is a dynamic two-wire set with a current draw of 35 mA as shown in the illustration. For SE1, connect TX 0 V and RX 0 V → 20, the marked terminal TX → 71 and the marked terminal RX → 71. For SE2, replace 71 with terminal 72; for SE3, use terminal 73. Terminal 5 and test terminal 18 are not used in this specific EL301 diagram. The TX/RX markings are system terminals; do not assign your own +24 V supply or polarity based on other photo eyes.

For EL31 the diagram shows receiver RX: 20 → 20 (0 V), 18 → 18 (test), 71/72/73 → 71 (signal according to the selected SE), 5 → 5 (+24 V). The transmitter TX has 20 → 20 (0 V), 5 → 5 (+24 V). The original color markings are GN/WH/BN; however, the actual terminal markings and the instructions for the supplied photo eye take precedence. For a different contact with its own power supply, use its own wiring diagram; a volt-free NC contact must not be confused with a +/− power supply.


Connect all safety devices before the learning process. After adding or changing safety devices, run the learning process again menu 10 and perform functional tests. After changing the direction of operation, reversing, speed or force in the advanced menus, repeat the safety tests.
Optional modules and external receiver
| Device | Wiring / function |
|---|---|
| External wired receiver | GN → 20 (0 V); BN → 5 (+24 V DC); WH → 21 (impulse); YE → 23 (partial opening). HEI3 BiSecur has a matching connector; ESEI BiSecur connects to the BUS. |
| HOR1 / UAP1 / UAP1-300 | Matching BUS connectors as shown in the illustration; HOR1 draws 25 mA, UAP1 45 mA. External relay functions in menu 30. |
| HNA Outdoor | Use the designated AKKU connection; switches over automatically in the event of a mains failure. Unplug the connector before servicing; disconnecting the mains does not disconnect the entire operator. |

Initial startup and selecting type 01
Safety devices must be connected, optical paths clear, the gate mechanically sound, and the area closed to people. During the learning process, the end positions, forces and connected safety devices are stored. The direction is determined during learning; after successful commissioning, it can only be changed by performing a factory reset and learning again.
- Switch on the power. The display first shows 8.8., then U. The type is preset on delivery; after a factory reset, use the T_AUF button to select 01 for the standard LineaMatic. Type 02/P or 03/H does not increase this operator's load capacity.
- Press and hold P. After the type and LA are displayed, the control unit enters end-position learning mode.
- Disengage the operator, open the gate by about 1 m, then re-engage it. Press and hold T_ZU; the gate must move towards the closed position. If it moves in the opposite direction, release the button briefly, then press and hold T_ZU again, following the manufacturer's procedure.
- When the gate stops at the magnetic limit switch, release the button. If the closed position is incorrect, adjust the magnetic slide and repeat the test.
- Press and hold T_AUF until the desired open position is reached, release it, make fine adjustments with T_AUF/T_ZU, then save by pressing P.
- To learn the forces, briefly press T_ZU and let the gate close; then press T_AUF and let it open fully. When complete, 11 flashes to indicate radio control learning. A safety device must not be activated while the forces are being learned.
- Store the desired transmitters or exit radio control learning mode. Check the safety devices and forces across the entire gate, refit the covers, and show the user how to disengage the operator manually.


Relearning after changing the gate or safety devices
Menu 10 erases the previous travel path and force settings. Once activated, it cannot be exited early; the learning process must be completed. Use after changing end positions or mechanics, servicing, or adding photo eyes or a safety edge. There is no standard time limit.
- Open the gate by about 1 m, select menu 10, and hold P for 5 seconds.
- Press T_ZU and let the gate travel to the closing limit switch.
- Press and hold T_AUF until the desired open position is reached, adjust as needed, and confirm with P.
- Start T_ZU to close fully and T_AUF to open fully so the forces are learned again.
- When finished, check all safety devices and operating settings.

Programming via the display
To enter, press and hold P for approximately 5 seconds, until 00 is displayed. T_AUF/T_ZU selects the menu or parameter. For a standalone function, hold P for 2 seconds; for a menu with parameters, press P briefly first, select the parameter, then hold P for 2 seconds to save. A dot next to the number indicates the active setting. Menu 00 followed by a brief press of P exits programming; the standard timeout is 60 seconds, or 25 seconds during radio control learning. Do not assume a new parameter has been saved unless it has been confirmed.

Only the factory-designated presets for the standard LineaMatic are shown in bold. The documented public menus are listed; after changing service settings for force, speed or reversing limits, repeat the safety tests.
Menus 30 and 31 – relay parameters
| Parameter | Description |
|---|---|
| 00 | Lighting function: external for 30, internal for 31. Menu 30/00 activates 26; 31/00 activates 22. |
| 01 / 02 / 03 | Open / closed / partially open position indication. |
| 04 | Pulse signal when an opening command is given; in menu 30, also when partially open, for the external relay. |
| 05 | Fault indication. |
| 06 | Continuous signal during start-up/pre-warning. |
| 07 | Default flashing during start-up/pre-warning. |
| 08 | Relay energised during movement and de-energised at the end positions. |
| 09 | Service interval indication In. |
| 10 | Flashing during start-up/pre-warning only when closing. |
For parameters 01–10, menu 25 is activated for the external relay and menu 20 for the internal relay. Pre-warning is effective only when menu 32 is enabled. Therefore, always check a relay change together with the menu linked to it automatically.
Menus 32, 34 and 35 – time options
| Menu 32 parameter | Time / function |
|---|---|
| 00 | off |
| 01 | 1 s |
| 02 | 2 s |
| 03 | 3 s |
| 04 | 4 s |
| 05 | 5 s |
| 06 | 10 s |
| 07 | 15 s |
| 08 | 20 s |
| 09 | 30 s |
| 10 | 60 s |
| Menu 34 parameter | Time / function |
|---|---|
| 00 | off |
| 01 | 5 s |
| 02 | 10 s |
| 04 | 30 s |
| 05 | 60 s |
| 06 | 90 s |
| 07 | 120 s |
| 08 | 180 s |
| 09 | 240 s |
| 10 | 300 s |
| Menu 35 parameter | Time / function |
|---|---|
| 00 | off |
| 01 | same as 34 |
| 02 | 5 min |
| 03 | 15 min |
| 04 | 30 min |
| 05 | 45 min |
| 06 | 60 min |
| 07 | 90 min |
| 08 | 120 min |
| 09 | 180 min |
| 10 | 240 min |
Activate automation 34/35 only after teaching the photocell. When they are enabled, the pre-warning 32/02 is automatically set to 2 seconds. During automatic closing, a new command will stop the gate. Set partial opening in menu 36; if it is too close to the closed position, the unit will display error 1 and use the minimum permitted position.
Storing remote controls
The integrated receiver stores up to 150 radio codes, divided among the functions. When capacity is exceeded, the oldest codes are deleted. If you store the same code for another function, its original assignment is removed. A code is not necessarily an entire transmitter with all its buttons.
- The gate must be stationary, with no active pre-warning or automatic closing time.
- Select 11 for an impulse or 12/13/14/15 for the desired alternative function, then briefly press P. The number flashes.
- Hold down the button on a compatible transmitter in code-transmission mode; when BiSecur is displayed, the red/blue LED alternates after approximately 5 seconds.
- When the menu number on the operator flashes rapidly, the code has been recognized. Release the button. Another code can be added within 25 seconds.
- Briefly press P to interrupt programming; use 00 and P to return to operation. Then test each stored function with the area secured.

Status feedback requires a suitable two-way transmitter with a position-check function; the 868 MHz frequency alone does not confirm this capability. Not every transmitter has a status button or uses the same battery procedure. For code sharing and resetting a specific transmitter, refer to its own manual.
Connecting an external receiver retrospectively
When connecting an external radio receiver retrospectively, the manufacturer requires you to delete the radio codes from the integrated receiver via menu 19. This will delete all transmitters and functions stored in it; before proceeding, make a note of the remotes in use and their assignments. Then teach the codes to the external receiver according to its own manual. The external receiver's antenna wire must not be placed next to metal objects.
Clearing the radio memory and factory reset
Menu 19 – delete all codes
Select 19 and hold P for 5 seconds. 19 first flashes slowly for 5 seconds, then rapidly for approximately 3 seconds; a steady 19. confirms deletion. All transmitters and all functions will be deleted. This procedure does not support deleting a single button or function individually.
Resetting the operator to factory settings
A factory reset restores the settings and deletes the learned travel paths and forces; radio codes are retained. Menu 10 is only for relearning the travel path/forces; menu 19 separately deletes the radio codes. Do not confuse these three procedures.
- Disconnect the mains supply and emergency battery as shown in the illustration. Secure the gate against movement.
- Hold down P and restore the mains supply.
- Keep holding P while 8.8. and C are displayed, until U appears; then release it.
- Select the correct type 01 and repeat the entire commissioning procedure. Also check the retained remotes, safety devices, times, and forces.

Reference run after disengagement or a power failure
A reference run may be required if the position is unknown after a power failure or after the force limit has been triggered three times. The next impulse will start it in the closing direction only, at reduced speed and without force limitation. The area must be secured; if it is not protected by a photocell or other device, the run may only be carried out with the gate in view. After manual disengagement without a power failure, once the power supply has been secured, disconnect it once more so that the new reference run is performed as described in the manual.
Display diagnostics
| Display | Meaning / procedure |
|---|---|
| U | The operator has not been taught; commission it. |
| 8.8. | Startup or loading of radio codes; this is not necessarily an error. |
| 1 s with a flashing dot | Cannot set the reversing limit or partial position; check for obstructions and clearance from the closed position. |
| 2.1 / 2.2 / 2.3 | SE1 / SE2 / SE3 protection: obstruction, misalignment, guide or device damage. |
| 3 / 5 | Force limit during closing/opening; remove the obstruction and check the mechanical travel rather than automatically increasing the force. |
| 4 | HALT12–13 interrupted; check the NC circuit and wiring. |
| 6 | System error or travel time limit; check the reset and relearn the system. 6 |
| System error or travel time limit; check the reset and relearn the system; if the operator is faulty, arrange for it to be repaired or replaced. | Communication error on the expansion board; check the wiring, connectors, and module. |
| 8 | Invalid input or control command; check the selected value. |
| 9 | Triggered/faulty tested safety device or 8k2; remove the obstruction and check the safety device. |
| 13 / 17 | Undervoltage / voltage error; check the power supply and battery. |
| C | Unknown reference point; secure the area and perform a reference run. |
| In | The service interval has elapsed; have the system inspected. |

Maintenance and safe handover
The manufacturer describes the operator as maintenance-free, but the entire gate requires regular inspection. Check safety and protective functions monthly, and check 8k2 resistance edges and untested safety devices every six months according to the manual. Check for smooth operation, secure rack fastening, guide alignment, cable damage, clean photocells, and correct disengagement function. Correct any defects without delay.
Before maintenance, disconnect all power sources and prevent them from being switched on again. After installation and any changes, check the effectiveness of the safety devices, reversing, and operating forces. Train the user, hand over the manuals, and attach the warning label visibly to the gate. Children must not play in the movement area; pass through only after the gate has come to a complete stop.
Technical specifications of Hörmann LineaMatic 4511323
| Parameter | Value |
|---|---|
| Model / type selection | Basic LineaMatic /01 |
| Maximum gate width / height | 6000 mm /2000 mm |
| Max. weight – ground-supported / cantilevered | 300 kg /250 kg |
| Mains supply | 230/240 V AC,50/60 Hz; permitted range 170–260 V AC. |
| Control voltage | 24 V/37 V DC, switchable internal control; not a universal output for accessories. |
| Accessory power supply | 24 V DC; 5=plus, 20=0 V; total max. 250 mA. |
| Radio frequency / memory | 868 MHz / up to 150 radio codes |
| Protection rating / temperature | IP44 / −20 to +60 °C |
| Maximum humidity | 93%, non-condensing |
| Standby power consumption | Less than 0.5 W |
| End positions | Magnetic REED switch sensor and electronically learned positions/forces. |
| Cycles per day/hour | As stated on the rating plate. |
| Housing | Cast aluminium and glass-fibre-reinforced plastic. |

The dimensioned drawing shows the housing 193 × 253 × 256 mm. When mounted on a floor plate, the overall height can be adjusted up to 327 mm; the plate shown has a footprint of 260 × 295 mm. Choose the actual mounting height relative to the rack based on dimension A, not just the external dimensions of the cover.