Hormann LineaMatic P - standalone drive for a sliding gate up to 500 kg/8 m, 4554309 (A)


Product availability: In stock

We normally dispatch goods within 24 hours.


Hormann LineaMatic P - standalone drive for a sliding gate up to 500 kg/8 m, 4554309 (A) Hormann LineaMatic P - standalone drive for a sliding gate up to 500 kg/8 m, 4554309 (A)
HOR-LINEAMATIC-P
In stock
€395.70 excluding VAT
€486.71 including VAT

 pcs
Weight
17 kg

Description of Hormann LineaMatic P - standalone drive for a sliding gate up to 500 kg/8 m, 4554309 (A)

The operator is designed for sliding gates with a travel length of 8m/500kg. The closed end position is detected by a magnet and a REED switch. The travel and forces are learned during commissioning. The operator is notreversible.

The operator includes a built-in control unit with an integrated bidirectional receiver for operating it with remote controls. The advantage of the bidirectional receiver is that you can check the status of the open gate directly on the remote control.

Hörmann LineaMatic P 4554309 is an operator for sliding gates up to 8 m wide and 2 m high. For a ground-track gate, the limit is 500 kg, and for a cantilever gate, 400 kg. The infill and local wind load must be assessed together with the gate's mechanical resistance.

Disconnect the mains supply and any emergency battery before opening. Secure the gate leaf against unintended movement and protect the main and secondary closing edges, as well as the rack's engagement point.

Installation, wiring and adjustment
Operator onlyAccessoriesInstallation
WiringManual releaseControl board
Terminals and power supplyPhotocells and safetyInitial start-up
Travel learningProgrammingRemote controls
Reset and memoryDiagnosticsMaintenance
Technical specificationsInstallation manual (PDF)

LineaMatic P operator only

This listing is for the operator only. Photocells, lights, remote controls, toothed racks and other accessories are selected for the specific setup; the following diagrams do not show the contents of the package.

Accessories and their connections

The specific examples shown in the diagrams are EL301, EL31, SLK, HOR 1, UAP 1/UAP 1-300 and HNA Outdoor. They are not included with the operator-only package. Hörmann SK-SET LineaMatic 437989 is a separate accessory offer. Always check the wiring against the label on the supplied device.

Installing the operator and preparing the gate

Preparing the gate and foundation

The gate must move smoothly and evenly by hand, have stable guidance and be mechanically secured against running off its track. Disable locks and mechanical restraints that prevent motorised movement. The operator is not a substitute for repairing a gate that is difficult to move or damaged. Continuous operation is not permitted. Use on a gate that slopes uphill or downhill requires radial dampers.

Choose the foundation according to whether the installation uses a floor plate. For an installation without closing-edge protection, the basic minimum dimensions shown in the cross-section are 345 × 280 mm; the specified distances 175 mm without a plate or 200 mm with a plate and the orientation relative to the gate must follow the complete diagram. With closing-edge protection, the basic minimum dimensions are 345 × 440 mm and the minimum clearance is 200 mm; choose any additional offsets according to the relevant version of the complete drawing below. Select a frost-free depth appropriate for the installation location; the 80 cm value in the manual is an example for Germany. The concrete must be sufficiently cured before installation; for a floor plate, the manufacturer requires compacted concrete of at least grade B25/C25.

LineaMatic foundation without and with floor plate – both orientations
LineaMatic foundation without and with floor plate – both orientations
Foundation with closing-edge protection – installation without a floor plate
Foundation with closing-edge protection – installation without a floor plate
Foundation with closing-edge protection – installation with a floor plate
Foundation with closing-edge protection – installation with a floor plate

Anchoring and installation height

The operator position depends on the specific rack. Dimension A in the drawing cannot be interchanged freely between different toothed racks.

Installation dimension for the original rack
Rack designationDimension A
436444124–136 mm
438759126–138 mm
438631125–129 mm
438632129–133 mm

Installation heights and dimension A for the individual toothed racks
Installation heights and dimension A for the individual toothed racks

For anchor bolts, use the drilling template and drill holes Ø 12 mm, depth 80 mm. For heavy-duty anchors and a floor plate, the holes are Ø 10 mm, depth 105 mm; the drawing specifies a tightening torque of 45 Nm for the anchoring shown. Protect the operator from dust and swarf. The installer must confirm the load-bearing capacity of the actual substrate and the suitability of the supplied anchors.

LineaMatic anchor bolts – Ø 12 mm holes
LineaMatic anchor bolts – Ø 12 mm holes
Installation through the floor plate – Ø 10 mm holes and anchoring dimensions
Installation through the floor plate – Ø 10 mm holes and anchoring dimensions

Fit the conduit seals and feed the cables into the housing from below. Position the operator level and secure it firmly. When the cover is open, protect the electronics from moisture; after installation, seal the housing against water and insects.

Positioning the housing and sealing the cable glands on the LineaMatic
Positioning the housing and sealing the cable glands on the LineaMatic

Rack and end-position magnet

The operator must be disengaged when installing the rack. The joints between individual sections must align smoothly without any offset. After installation, align the rack, pinion and operator housing with one another; follow the dimensions in the relevant diagram, not values taken from another brand. Incorrect meshing can cause unwanted reversal.

Securing and aligning the LineaMatic toothed rack
Securing and aligning the LineaMatic toothed rack

The closed end position is detected by a magnet and a REED switch. Move the gate manually to the closed position, preassemble the magnetic slide in the middle position and secure it approximately 20 mm from the reed switch as shown in the illustration. Then check the final position and fine-tune it during the learning run.

Mains connection, board holder and magnet position with 20 mm dimension
Mains connection, board holder and magnet position with 20 mm dimension

Wiring and separation of voltages

Wiring for the configuration described
CircuitRequirement
Mains230/240 V AC; 3 × 1.5 mm² supply cable, with a suitable underground cable as specified in the instructions when buried. Use a separate conduit.
AccessoriesRoute 24 V circuits separately from the mains. Terminals for 0.5–2.5 mm² conductors.
External push buttonMaximum cable length: 30 m.
HALT and safety circuits shown in the diagramsMaximum cable length: 10 m, depending on the specific wiring diagram.
Extending underground cablesUse a suitable IP65-rated junction box; do not leave the connection unprotected underground.

Manual release and re-engagement

  1. Disconnect the mains and any HNA Outdoor unit. Secure the gate against uncontrolled movement.
  2. Open the cover and turn the release mechanism to the release position as shown in the illustration. The motor with the gear wheel will lower into the housing; gently push them down if necessary.
  3. Move the gate manually and under control. Keep your hands clear of the rack engagement area.
  4. To re-engage the drive, turn the mechanism to the locked position while slightly raising the motor. The gate must re-engage with the drive before reaching the limit switch.
  5. Replace the cover. After power is restored, the drive may make a reference run towards the closed position; keep the area clear and supervise it.
Opening the LineaMatic drive and manual release
Opening the LineaMatic drive and manual release
Re-engaging the drive – raise the motor slightly while turning the mechanism
Re-engaging the drive – raise the motor slightly while turning the mechanism

Orientation of the control board

The illustration is oriented with the buttons T_AUF, P and T_ZU at the top and the long row of terminals at the bottom. BUS is at the top, by the buttons, REED and HALT are on the left, SE3 is on the raised section above SE1/SE2 at the bottom. MOTOR, SNT and the AKKU connection are on the right. Use the connector labels to distinguish signal, motor and power circuits.

LineaMatic board – exact terminal and connector labels
LineaMatic board – exact terminal and connector labels

Power supply, polarity and control terminals

LineaMatic terminals and distinguishing power connections from control inputs
Terminal / connectorFunction and limit
Mains section L / N and enclosure PE230/240 V AC mains, 50/60 Hz; L is live, N neutral and PE protective earth. AC has no positive or negative polarity. Connect the supply to the mains section, not to the signal terminals.
5 / 205 = positive (+24 V DC), 20 = 0 V (−). Total current draw of accessories: maximum 250 mA; include all connected devices in the calculation.
24 V=: 24 V / 0 VSeparately labelled DC output: 24 V = positive, 0 V = negative. For example, use it for a 24 V light as shown in the wiring diagram; it is not a 230 V output.
21 / 20NO voltage-free pulse or contact switching to 0 V. Push buttons can be wired in parallel; the contact itself has no +/− polarity.
23 / 20NO voltage-free partial-opening command; 23 is the signal, 20 is common 0 V, not a power supply pair.
HALT 12 / 13NC voltage-free STOP; 13 = 0 V, 12 is the input. When installing the STOP button, remove the factory jumper between 12–13 and connect the NC contact.
REEDReed-switch limit sensor for the original configuration; do not connect an external voltage.
BUSSystem accessories with the matching connector. This is not a universal +/− output for arbitrary devices.
MOTOR / SNT / AKKUMotor, mains section and designated emergency battery. Use the original connectors and observe the marked polarity; disconnect the battery as well before working.

Applying an external voltage to the control inputs may damage the electronics. Do not connect 230 V to 21/23/HALT or SE. HALT is not a monitored PLc-level safety input; do not use it in place of an SE protective device.

REED, external receiver and NO push buttons 20–21 / 20–23
REED, external receiver and NO push buttons 20–21 / 20–23
NC HALT stop on 12–13
NC HALT stop on 12–13

SLK warning light and Option relay

Relay Option has voltage-free contacts .5 common, .8 NO, .6 NC. For a 24 V light, the wiring diagram uses 24 V (+) → .5, .8 → light, light return → 0 V (−). For a polarity-sensitive light, connect its positive input to the switched supply from .8 and its negative input to 0 V. The manufacturer specifies for this 24 V light max. 7 W; also observe the total accessory limit—the 7 W rating does not increase it. The internal relay function is set using menu 31.

Original light wiring diagrams – 24 V DC via the 24V= output and 230 V AC with its own power supply
Original light wiring diagrams – 24 V DC via the 24 V= output and 230 V AC with its own power supply

The 230 V light has its own external mains supply; the manufacturer's wiring diagram specifies a maximum of 500 W. Mains conductors must have additional insulation all the way to the connection. Follow the complete PDF when wiring; 230 V must not enter low-voltage circuits.

Photocells and SE1/SE2/SE3 safety inputs

Power and signal terminals for safety circuits
InputTerminals and response shown in the instructions
SE15 = +24 V DC; 20 = 0 V (−); 18 = test, 71 = signal. Acts during closing and briefly reverses the direction.
SE25 = +24 V DC; 20 = 0 V (−); 18 = test, 72 = signal. Activates during opening and briefly reverses.
SE35 = +24 V DC; 20 = 0 V (−); 18 = test, 73 = signal. Activates during closing and briefly reverses.

After wiring, set and test the operating direction and reversal of each safety device for the specific gate. SE1 and SE2 support dynamic two-wire photocells, tested or untested three-wire photocells, an 8k2 resistive safety edge, and specified safety-edge protection. Photocells are shown here for SE3; do not transfer the SE1/SE2 resistive safety-edge wiring to SE3. Two photocells on one circuit require an LSE2 expander. According to the manual, untested safety devices are permitted only for property protection.

EL301 – exact wiring according to the original diagram

EL301 is a dynamic two-wire assembly with a current draw of 35 mA as shown. For SE1, connect TX 0 V and RX 0 V → 20, the marked terminal TX → 71 and the marked terminal RX → 71. For SE2, replace 71 with terminal 72; for SE3, use terminal 73. Terminal 5 and test terminal 18 are not used in this specific EL301 diagram. TX/RX designations are system terminals; do not assign them your own +24 V power supply or polarity based on other photocells.

SE1 – original wiring for EL301, EL31, 8k2 and contact photocell
SE1 – original wiring for EL301, EL31, 8k2 and contact photocell

For EL31 the following connections run from the drive control board to the photocell. Power supply to both the RX receiver and TX transmitter: board 20 → 20 (0 V/−, GN), board 5 → 5 (+24 V DC, BN). RX receiver test: board 18 → 18 (WH). Connect the WH signal wire from the RX receiver to the drive control board at 71 for SE1, 72 for SE2 or 73 for SE3. Use the full diagram for the relevant SE and compare the supplied photocell's markings with its manual. For a different contact with its own power supply, use its own diagram; a volt-free NC contact must not be confused with a +/− power supply.

SE2 – separate wiring, signal 72 and protection during opening
SE2 – separate wiring, signal 72 and protection during opening
SE3 – separate photocell wiring with signal 73
SE3 – separate photocell wiring with signal 73

Connect all safety devices before the learning cycle. After adding or changing a safety device, perform a new learning cycle using menu 10 and carry out functional tests. After changing the operating direction, reversal, speed or force in the advanced menus, repeat the safety tests.

Optional modules and external receiver

Examples of optional accessories
DeviceWiring / function
External wired receiverGN → 20 (0 V); BN → 5 (+24 V DC); WH → 21 (impulse); YE → 23 (partial opening). HEI3 BiSecur has a compatible connector; ESEI BiSecur connects to the BUS.
HOR1 / UAP1 / UAP1-300Use the corresponding BUS connectors as shown; HOR1 draws 25 mA and UAP1 draws 45 mA. External relay functions in menu 30.
HNA OutdoorUse the designated AKKU connection; it switches over automatically in the event of a mains failure. With the board oriented as shown, + is on the left and − on the right; the black BK wire goes to −. Use the original connector and observe the polarity markings for the specified battery. Unplug the connector before servicing; disconnecting the mains does not isolate the entire drive.

Original connections for HOR1, UAP1 and the emergency battery
Original connections for HOR1, UAP1 and the emergency battery

Initial start-up and selecting type 02

Safety devices must be connected, the optical paths clear, the gate mechanically sound, and the area closed off to people. During the learning cycle, the end positions, forces and connected safety devices are stored. The direction is determined during the learning cycle; after successful commissioning, it can be changed only by a factory reset followed by a new learning cycle.

  1. Switch on the power. The display first shows 8.8., then U. The type is preset on delivery; after a factory reset, use the T_AUF button to select 02 for LineaMatic P. Select only the type that matches the actual drive; another selection changes the speed and safety settings.
  2. Press and hold P. Hold for approximately 2 seconds. After the type and LA appear, the control unit starts learning the end positions.
  3. Disengage the drive, open the gate by approximately 1 m, then re-engage the drive. Press and hold T_ZU; the gate must move towards the closed position. If it moves in the opposite direction, briefly release and press and hold T_ZU again, following the manufacturer's procedure.
  4. When the magnetic limit switch stops the gate, release the button you are holding. If the closed position is incorrect, move the magnetic carriage, briefly press and hold T_AUF to move the gate away from the limit switch, then press and hold T_ZU until it stops at the limit switch again. Repeat this procedure as needed.
  5. Press and hold T_AUF until the desired open position is reached, release it, fine-adjust with T_AUF/T_ZU, then save by pressing P.
  6. To learn the forces, briefly press T_ZU and let the gate close; then press T_AUF and let it open fully. When complete, 11 flashes to indicate radio learning. Do not activate any safety device while the forces are being learned.
  7. Store the desired transmitters or end radio learning. Check the safety devices and forces across the full gate travel, fit the covers, and show the user how to disengage the drive manually.
Initial learning – selecting 02 for LineaMatic P, closed and open positions
Initial learning – selecting 02 for LineaMatic P, closed and open positions
Force learning – fully closing and opening
Force learning – fully closing and opening

Repeating the learning cycle after changing the gate or safety devices

Menu 10 erases the previously learned travel and forces. Once activated, it cannot be exited early; the learning cycle must be completed. Use after changing the end positions or mechanics, after servicing, or after adding photocells or a safety edge. There is no normal time limit.

  1. Open the gate by approximately 1 m, select menu 10, and hold P for 5 seconds.
  2. Press T_ZU and let the gate travel to the closing limit switch.
  3. Press and hold T_AUF until the desired open position is reached, fine-adjust as needed, and confirm with P.
  4. Run T_ZU to close the gate fully and T_AUF to open it fully so the forces are learned again.
  5. When complete, 10 flashes rapidly for approximately 2 seconds, then stays lit. Select 00 and briefly press P to return to operation. Check all safety devices and operating settings.
Menu 10 – relearning the end positions
Menu 10 – relearning the end positions
Menu 10 – completing force learning by fully closing and opening
Menu 10 – completing force learning by fully closing and opening

Programming using the display

To enter, press and hold P for approximately 5 seconds, until 00 appears. T_AUF/T_ZU selects a menu or parameter. For a standalone function, hold P for 2 seconds; for a menu with parameters, briefly press P first, select the parameter, then hold P for 2 seconds to save. A dot next to the number indicates the active selection. Select menu 00 and briefly press P to exit programming; the normal time limit is 60 seconds, or 25 seconds during radio learning. Do not assume a new parameter has been saved unless it has been confirmed.

Entering, selecting and confirming the public LineaMatic menus
Entering, selecting and confirming the public LineaMatic menus

The tables show the available selections and how to save them. After setup, check the active parameter and the operation of the entire gate. The public menus are listed here; after changing service settings for force, speed, or reversal limits, repeat the safety tests.

LineaMatic P public menu
Menu / functionOptions and conditions
00 – Entry / exitReturn to operation via 00 and a brief press of P.
02 – Drive type02 – LineaMatic P. Only for initial commissioning or after a factory reset; select according to the actual drive.
10 – New learning cycleHold P for 5 s; this deletes the travel path/forces and requires the learning cycle to be completed again.
11 – Radio – impulseTeach in the code for the main sequence command.
12 – Radio – lightTeach in the light function with the appropriate external relay/module.
13 – Radio – partial openingTeach in the partial-opening code.
14 – Radio – openSeparate opening direction: open–STOP–open.
15 – Radio – closeSeparate closing direction: close–STOP–close.
19 – Delete all radio codesHold P for 5 s; this deletes all functions and all transmitters.
20 – Internal light offDeactivates the movement-triggered light; automatically selects 31/07.
21 – Internal light 30 sLight remains on after operation ends; activates 31/00.
22 – Internal light 60 s60 s of follow-on lighting; activates 31/00.
23 – Internal light 120 sLight remains on after operation ends; activates 31/00.
24 – Internal light 180 sLight remains on after operation ends; activates 31/00.
25 – External light offAn external light command will not switch it on.
26 – External light 5 min5 min timer. The light is triggered by an external command.
27 – External light 10 minExternal lighting duration.
28 – External light ON/OFFContinuous on/off control via HOR1 or UAP1 relay 3; do not combine with 25.
30 – External relay functionHOR1/UAP1/UAP1-300; see parameters below.
31 – Internal relay functionOption contacts; see parameters below.
32 – Pre-warningOptions 00–10 as shown in the table below.
34 – Automatic closingRequires a connected and taught-in photocell; see settings below.
35 – Automatic closing after partial openingRequires a taught-in photocell; see settings below.
36 – Partial-opening positionHold P for 5 s, use T_AUF/T_ZU to set the position, then press P to save. The control unit will reject a position that is too close.

Menus 30 and 31 – relay parameters

Relay function parameters
ParameterMeaning
00Lighting function: external for 30, internal for 31. Menu 30/00 activates 26; menu 31/00 activates 22.
01 / 02 / 03Indicates the open / closed / partially open position.
04Pulse signal on an open command; in menu 30, also on partial opening when using the external relay.
05Error indication.
06Continuous signal during start-up/pre-warning.
07Flashing during start-up/pre-warning.
08Relay closed during movement and open at the end positions.
09Service interval indication In.
10Flashing during start-up/pre-warning only when closing.

For parameters 01–10, menu 25 is activated for the external relay and menu 20 for the internal relay. Pre-warning is effective only when menu 32 is activated. Therefore, always check relay changes together with the automatically associated menu.

Menus 32, 34 and 35 – time settings

Pre-warning
Menu 32 parameterTime / function
00off
011 s
022 s
033 s
044 s
055 s
0610 s
0715 s
0820 s
0930 s
1060 s

Wait time after fully opening
Menu 34 parameterTime / function
00off
015 s
0210 s
0430 s
0560 s
0690 s
07120 s
08180 s
09240 s
10300 s

Waiting after partial opening
Menu parameter 35Time / function
00off
01same as 34
025 min
0315 min
0430 min
0545 min
0660 min
0790 min
08120 min
09180 min
10240 min

Activate the automatic functions 34/35 only after teaching in the photocell. When they are switched on, the pre-warning 32/02 is set automatically to 2 seconds. During automatic closing, a new command stops the gate. Set partial opening in menu 36; if it is too close to the closed position, the control unit reports error 1 and uses the smallest permitted position.

Storing remote controls

The integrated receiver stores up to 150 radio codes, shared between functions. When capacity is exceeded, the oldest codes are deleted. If you store the same code for another function, its original assignment is removed. A code is not necessarily an entire transmitter with all its buttons.

  1. The gate must be stationary, with no active pre-warning or automatic closing time.
  2. Select 11 for an impulse, or 12/13/14/15 for the desired alternative function, and briefly press P. The number flashes.
  3. Press and hold a button on a compatible transmitter in code-transmission mode; when BiSecur is displayed, the red/blue LED alternates after approximately 5 seconds.
  4. When the menu number on the operator flashes rapidly, the code has been recognised. Release the button. Another code can be added within 25 s.
  5. Briefly press P to interrupt programming; use 00 and P to return to operation. Then test each stored function with the area secured.
Programming a BiSecur code via menu 11
Programming a BiSecur code via menu 11

Status feedback requires a suitable bidirectional transmitter with position-checking capability; the 868 MHz frequency alone does not confirm this feature. Not every transmitter has a status button or the same battery procedure. For code sharing and resetting a specific transmitter, refer to its own instructions.

Connecting an external receiver later

When connecting an external radio receiver later, the manufacturer requires you to delete the radio codes from the integrated receiver via menu 19. This will delete all transmitters and functions stored in it; before proceeding, make a note of the remotes in use and their assignments. Then program the codes into the external receiver according to its own instructions. The external receiver’s antenna wire must not touch metal objects.

Deleting radio codes and factory reset

Menu 19 – delete all codes

Select 19 and hold P for 5 seconds. The number 19 flashes slowly for 5 seconds, then rapidly for approximately 3 seconds; a steady 19. confirms deletion. All transmitters and all functions will be deleted. This procedure does not support deleting a single button or function individually.

Resetting the operator to factory settings

A factory reset restores the settings and deletes the learned travel limits and forces; radio codes are retained. Menu 10 is for relearning the travel limits/forces only; menu 19 deletes radio codes only. Do not confuse these three procedures.

  1. Disconnect the mains and emergency battery as shown. Secure the gate to prevent movement.
  2. Hold down the P button and restore the mains power supply.
  3. Keep holding P while 8.8. and C are displayed, until U appears, then release it.
  4. Select the correct type, 02 for LineaMatic P, and repeat the entire commissioning procedure. Also check the retained remotes, safety devices, times and forces.
LineaMatic factory reset – disconnecting the mains/battery and holding P
LineaMatic factory reset – disconnecting the mains/battery and holding P

Reference run after disengagement or a power failure

A reference run may be required if the position is unknown after a power failure or after the force limit has been triggered three times. The next impulse starts it only in the closing direction, at reduced speed and without force limitation. The area must be secured; if it is not protected by a photocell or another device, the gate may be operated only while it remains in view. After manual disengagement without a power failure, once the power supply is secured, disconnect it once more so that the new reference run can be carried out as instructed.

Display diagnostics

Error messages and basic status indications
DisplayMeaning / procedure
UThe operator has not been programmed; carry out commissioning.
8.8.Startup or loading radio codes; this is not necessarily an error.
1 s with flashing dotReversal limit or partial position cannot be set; check for obstructions and the clearance from the closed position.
2.1 / 2.2 / 2.3SE1 / SE2 / SE3 protection: obstruction, misalignment, wiring fault or device damage.
3 / 5Force limit reached during closing / opening; remove the obstruction and check mechanical operation—do not automatically increase the force.
4HALT12–13 circuit interrupted; check the NC circuit and wiring.
6System error or run-time limit reached; check the reset and relearning procedure. If the operator is faulty, arrange for it to be repaired or replaced.
7Communication error on the add-on board; check the wiring, connectors and module.
8Invalid input or operation; check the selected value.
9Triggered/faulty tested safety device or 8k2; remove the obstruction and check the safety device.
13 / 17Undervoltage / voltage error; check the power supply and battery.
CReference point unknown; secure the area and carry out a reference run.
InService interval elapsed; have the assembly inspected.

Original symbols for operating states and display indicators
Original symbols for operating states and display indicators

Maintenance and safe handover

The manufacturer describes the operator as maintenance-free, but the entire gate requires regular inspection. Check safety and protective functions monthly, and 8k2 resistance edges and untested safety devices every six months, as instructed. Check for smooth operation, secure rack fastening, the guide system, cable damage, clean photocells and proper disengagement function. Rectify any defects immediately.

Before maintenance, disconnect all power sources and prevent them from being switched on again. After installation and any changes, check the effectiveness of the safety devices, reversal and operating forces. Train the user, hand over the instructions, and attach the warning label in a visible position on the gate. Children must not play in the movement area; pass through only after the gate has come to a complete stop.

Technical specifications of Hörmann LineaMatic P 4554309

LineaMatic P and power circuit specifications
ParameterValue
Model / type selectionLineaMatic P /02
Maximum gate width / height8000 mm /2000 mm
Max. weight – ground-supported / cantilever500 kg /400 kg
Mains supply230/240 V AC,50/60 Hz; permitted range 170–260 V AC.
Control voltage24 V/37 V DC, switchable internal control; not a universal output for accessories.
Accessory power supply24 V DC;5=positive,20=0 V; total max.250 mA.
Radio frequency / memory868 MHz / up to 150 radio codes
Ingress protection / temperatureIP44 /−20 to+60 °C
Maximum humidity93%, non-condensing
Standby power consumptionLess than 0.5 W
End positionsMagnetic REED switch sensor and electronically learned positions/forces.
Cycles per day/hourAccording to the rating plate.
HousingMetal casting and glass-fibre-reinforced plastic, weather-resistant.

Original housing dimensions – installation without and with the floor plate
Original housing dimensions – installation without and with the floor plate

The dimensional drawing shows the housing 193 × 253 × 256 mm. When installed on the floor plate, the total height can be adjusted up to 327 mm; the plate shown has a footprint of 260 × 295 mm. Choose the actual installation height relative to the rack based on dimension A, not just the cover’s external dimensions.

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about Hormann LineaMatic P - standalone drive for a sliding gate up to 500 kg/8 m, 4554309 (A)

Product: Hormann LineaMatic P - standalone drive for a sliding gate up to 500 kg/8 m, 4554309 (A)
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.