Hormann LineaMatic H – standalone operator for sliding gates up to 800 kg/10 m, 4554321
| Product availability: | In stock | We normally dispatch goods within 24 hours. |
|---|
in stock
€706.38 including VAT
| Weight |
|---|
| 20 kg |
Description of Hormann LineaMatic H – standalone operator for sliding gates up to 800 kg/10 m, 4554321
The operator is designed for sliding gates with a travel length of 10m/800kg. The closed end position is detected by a magnet and a REED switch. The travel and forces are learned during commissioning. The operator is non-reversible.
The operator includes a built-in control unit without a radio receiver.
Hörmann LineaMatic H 4554321 is an operator for sliding gates up to 10 m wide. For a ground-track gate, the limit is 800 kg, and for a cantilever gate, 600 kg. The gate infill and local wind load must be assessed together with the gate's mechanical resistance.
Disconnect the mains supply and any emergency battery before opening. Secure the gate leaf against unintended movement and protect the main and secondary closing edges, as well as the area where the rack engages.
LineaMatic H operator only
This listing is for the operator only. Photoelectric sensors, lights, remote controls, toothed racks and other accessories are selected for the specific setup; the diagrams below do not indicate what is included in the package.
Accessories and their connections
Specific examples shown in the diagrams include EL301, EL31, SLK, HOR 1, UAP 1/UAP 1-300 and HNA Outdoor. They are not included with the operator-only package. Hörmann SK-SET LineaMatic 437989 is sold separately as an accessory. Always check the wiring against the markings on the supplied device.
Installing the operator and preparing the gate
Preparing the gate and foundation
The gate must move smoothly and evenly by hand, have stable guidance and be mechanically secured against derailing. Disable locks and mechanical restraints that prevent motorized movement. The operator does not replace repairs to a gate that is difficult to move or damaged. Continuous operation is not permitted. Use on a gate with an uphill or downhill slope requires radial dampers.
Choose the foundation to suit installation with or without a floor plate. For a setup without closing-edge protection, the basic minimum dimensions in section are 345 × 280 mm; observe the specific distances 175 mm without a plate or 200 mm with a plate and the orientation relative to the gate as shown in the complete diagram. For a setup with closing-edge protection, the basic minimum dimensions are 345 × 440 mm and the minimum clearance is 200 mm; choose any further offsets according to the relevant version of the full drawing below. Choose a frost-free depth appropriate for the installation location; the 80 cm shown in the manual is an example for Germany. The concrete must be sufficiently cured before installation; for a floor plate, the manufacturer specifies compacted concrete of at least grade B25/C25.



Anchoring and installation height
The operator position depends on the specific rack. Dimension A shown in the drawing is not interchangeable between different toothed racks.
| Rack designation | Dimension A |
|---|---|
| 436444 | 124–136 mm |
| 438759 | 126–138 mm |
| 438631 | 125–129 mm |
| 438632 | 129–133 mm |

For anchor bolts, use the drilling template and drill holes Ø 12 mm, 80 mm deep. For heavy-duty anchors and a floor plate, drill holes Ø 10 mm, 105 mm deep; the drawing specifies a tightening torque of 45 Nm for the anchoring shown. Protect the operator from dust and swarf. The installer must verify the load-bearing capacity of the actual substrate and the suitability of the supplied anchors.


Fit the conduit seals and route the cables into the housing from below. Set the operator level and secure it firmly. With the cover open, protect the electronics from moisture; after installation, seal the housing against water and insects.

Rack and end-position magnet
The operator must be disengaged when installing the rack. The joints between individual sections must align smoothly, without any offset. After installation, align the rack, pinion and operator housing with one another; follow the dimensions in the relevant diagram, not values taken from another brand. Incorrect meshing can cause unwanted reversal.

The closed end position is detected by Magnet and REED reed contact. Move the gate manually to the closed position, pre-fit the magnetic slider in the middle position and secure it approximately 20 mm towards the reed contact as shown in the diagram. Then check the final position and fine-tune it during the learning process.

Wiring and separation of voltages
| Circuit | Requirement |
|---|---|
| Mains | 230/240 V AC; 3 × 1.5 mm² supply cable; underground, use a suitable ground cable as specified in the instructions. Separate conduit. |
| Accessories | Route 24 V circuits separately from the mains. Terminals for 0.5–2.5 mm² conductors. |
| External push button | Cable run: maximum 30 m. |
| HALT and safety circuits shown in the diagrams | Cable run: maximum 10 m, depending on the specific wiring diagram. |
| Extending underground cables | Use a suitable junction box with IP65 protection; the connection must not be left unprotected underground. |
Manual release and re-engagement
- Disconnect the mains and any HNA Outdoor unit. Secure the gate against uncontrolled movement.
- Open the cover and turn the release mechanism to the release position as shown in the diagram. The motor and gear wheel lower into the housing; press them down gently if necessary.
- Move the gate manually and under control. Keep your hands clear of the rack mesh.
- To re-engage the drive, turn the mechanism to the locked position while gently lifting the motor. The gate must re-engage with the drive before reaching the limit switch.
- Replace the cover. After power is restored, a reference run towards the closed position may start; keep the area clear and supervise the gate.


Orientation of the control board
The diagram is oriented with the buttons T_AUF, P and T_ZU at the top and the long row of terminals at the bottom. BUS is at the top by the buttons, REED and HALT on the left, SE3 on the raised section above SE1/SE2 at the bottom. MOTOR, SNT and the AKKU connection are on the right. Use the connector labels to distinguish signal, motor and power circuits.

Power supply, polarity and control terminals
| Terminal / connector | Function and limit |
|---|---|
| Mains section L / N and enclosure PE | 230/240 V AC mains, 50/60 Hz; L is live, N is neutral and PE is protective earth. AC has no positive or negative polarity. Connect the supply to the mains section, not to the signal terminals. |
| 5 / 20 | 5 = positive (+24 V DC), 20 = 0 V (−). Total accessory current draw: maximum 250 mA; include all connected devices in the calculation. |
| 24 V= : 24 V / 0 V | Separately labelled DC output: 24 V = +, 0 V = −. For example, use it for a 24 V light as shown in the wiring diagram; it is not a 230 V output. |
| 21 / 20 | NO voltage-free pulse input or contact switched to 0 V. Push buttons can be wired in parallel; the contact itself has no +/− polarity. |
| 23 / 20 | NO voltage-free partial-opening command; 23 is the signal, 20 is common 0 V—not a power supply pair. |
| HALT 12 / 13 | NC voltage-free STOP; 13 = 0 V, 12 is the input. When installing the STOP, remove the original 12–13 jumper and connect an NC contact. |
| REED | Reed limit sensor for the original configuration; do not connect an external voltage source. |
| BUS | System accessories with the matching connector. This is not a universal +/− output for arbitrary devices. |
| MOTOR / SNT / AKKU | Motor, mains section and designated emergency battery. Use the original connectors and observe the marked polarity; disconnect the battery as well before working. |
External voltage applied to the control inputs can damage the electronics. Do not connect 230 V to 21/23/HALT or SE. HALT is not a monitored PLc-level safety input; do not use it in place of an SE protective device.


SLK beacon and Option relay
Relay Option has voltage-free contacts .5 common, .8 NO, .6 NC. For a 24 V light, the wiring diagram uses 24 V (+) → .5, .8 → light, light return → 0 V (−). For a polarity-sensitive light, connect its positive input to the switched feed from .8 and its negative input to 0 V. For this 24 V light, the manufacturer specifies max. 7 W; also observe the total accessory limit—the 7 W rating does not increase it. The internal relay function is set using menu 31.

The 230 V light has its own external mains supply; the manufacturer's diagram specifies a maximum of 500 W. Mains conductors must have additional insulation all the way to the connection. Follow the complete PDF for wiring; 230 V must not enter the low-voltage circuits.
Photocells and SE1/SE2/SE3 safety inputs
| Input | Terminals and response shown in the instructions |
|---|---|
| SE1 | 5 = +24 V DC; 20 = 0 V (−); 18 = test, 71 = signal. Active during closing; briefly reverses direction. |
| SE2 | 5 = +24 V DC; 20 = 0 V (−); 18 = test, 72 = signal. Active during opening; briefly reverses. |
| SE3 | 5 = +24 V DC; 20 = 0 V (−); 18 = test, 73 = signal. Active during closing; briefly reverses. |
After wiring, set and test the direction of operation and reversal of each safety device for the specific gate. SE1 and SE2 support dynamic two-wire photocells, tested or untested three-wire photocells, an 8k2 resistive safety edge, and the specified safety edge system. Photocells are shown here for SE3; do not transfer the resistive safety edge wiring for SE1/SE2 to SE3. Two photocells on one circuit require an LSE2 expander. According to the manual, untested safety devices are permitted only for property protection.
EL301 – exact wiring according to the original diagram
EL301 is a dynamic two-wire assembly with a current draw of 35 mA as shown in the figure. For SE1, connect TX 0 V and RX 0 V → 20, the marked terminal TX → 71 and the marked terminal RX → 71. For SE2, use terminal 72 instead of 71; for SE3, use terminal 73. Terminal 5 and test terminal 18 are not used in this specific EL301 diagram. TX/RX designations refer to system terminals; do not assign them a separate +24 V supply or polarity based on other photocells.

For EL31 the following connections run from the drive control board to the photocell. Power supply for both the RX receiver and TX transmitter: board 20 → 20 (0 V/−, GN), board 5 → 5 (+24 V DC, BN). RX receiver test: board 18 → 18 (WH). Connect the WH signal wire from the RX receiver to the drive control board at 71 for SE1, 72 for SE2 or 73 for SE3. Use the complete diagram for the relevant SE and compare the markings on the supplied photocell with its manual. For a different contact with its own power supply, use its own wiring diagram; a volt-free NC contact must not be confused with a +/− power supply.


Connect all safety devices before programming. After adding or changing safety devices, carry out a new programming cycle menu 10 and functional tests. After changing the direction of operation, reversal, speed or force in the advanced menus, repeat the safety tests.
Optional modules and external receiver
| Device | Connection / function |
|---|---|
| External wired receiver | GN → 20 (0 V); BN → 5 (+24 V DC); WH → 21 (impulse); YE → 23 (partial opening). HEI3 BiSecur has the appropriate connector; ESEI BiSecur connects to BUS. |
| HOR1 / UAP1 / UAP1-300 | Corresponding BUS connectors as shown; HOR1 draws 25 mA, UAP1 45 mA. External relay functions in menu 30. |
| HNA Outdoor | Dedicated AKKU connection, with automatic switchover in the event of a mains failure. In the board orientation shown, + is on the left and − on the right; the black BK wire connects to −. Use the original connector and polarity markings for the specified battery. Disconnect the connector before servicing; do not assume that disconnecting the mains isolates the entire drive. |

Initial start-up and selecting type 03
Safety devices must be connected, optical paths clear, the gate mechanically sound, and the area closed off to people. During programming, the end positions, forces and connected safety devices are recorded. The direction is determined during programming; after successful commissioning, it can only be changed by performing a factory reset and programming again.
- Switch on the power. The display first shows 8.8., then U. The type is preset at delivery; after a factory reset, use the T_AUF button to select 03 for LineaMatic H. Select only the type that matches the actual drive; another selection changes the speed and safety settings.
- Press and hold P. Hold for approximately 2 seconds. After the type and LA are displayed, the unit enters end-position programming mode.
- Disengage the drive, open the gate by approximately 1 m, then re-engage the drive. Press and hold T_ZU; the gate must move toward the closed position. If it moves in the opposite direction, release briefly and press and hold T_ZU again, following the manufacturer's procedure.
- When the gate stops at the magnetic limit switch, release the button you are holding. If the closed position is not correct, move the magnetic carriage, briefly press and hold T_AUF so the gate moves away from the limit switch, then press and hold T_ZU until it stops at the limit switch again. Repeat this procedure as needed.
- Press and hold T_AUF until the desired open position is reached, release it, fine-tune using T_AUF/T_ZU, then save with P.
- Briefly press T_ZU and let the gate close to program the forces; then press T_AUF and let it open fully. The safety device must not be activated while the forces are being programmed.
- If fitted, configure the external receiver according to its manual. Check the safety devices and forces for the entire gate, fit the covers, and show the user how to disengage the drive manually.

Reprogramming after changing the gate or safety devices
Menu 10 erases the previously programmed travel path and forces. Once activated, it cannot be exited early; programming must be completed. Use after changing end positions or the mechanics, servicing, or adding photocells or a safety edge. There is no standard time limit.
- Open the gate by approximately 1 m, select menu 10, and hold P for 5 seconds.
- Press T_ZU and let the gate reach the closing limit switch.
- Press and hold T_AUF until the desired open position is reached, adjust as needed, and confirm with P.
- Run T_ZU to close fully and T_AUF to open fully so the forces are programmed again.
- When complete, 10 flashes rapidly for approximately 2 seconds, then remains lit. Select 00 and briefly press P to return to operation. Check all safety devices and operating settings.


Programming via the display
To enter, press and hold P for approximately 5 seconds, until 00 is displayed. T_AUF/T_ZU selects a menu or parameter. For a standalone function, hold P for 2 seconds; in a menu with parameters, briefly press P first, select the parameter, then hold P for 2 seconds to save. A dot next to the number indicates the active selection. Select menu 00 and briefly press P to exit programming; the standard timeout is 60 seconds. Do not assume that a new parameter has been saved unless it has been confirmed.

The tables show the available selections and how to save them. After configuration, check the active parameter and the operation of the entire gate. The menus shown are public menus; after changing service settings for force, speed or reversal limits, repeat the safety tests.
Menus 30 and 31 – relay parameters
| Parameter | Meaning |
|---|---|
| 00 | Lighting function: external for 30, internal for 31. Menu 30/00 switches on 26; 31/00 switches on 22. |
| 01 / 02 / 03 | Open / closed / partially open position signal. |
| 04 | Pulse signal when an opening command is issued; in menu 30, also for partial opening via the external relay. |
| 05 | Fault signal. |
| 06 | Steady signal during start-up/pre-warning. |
| 07 | Flashing during start-up/pre-warning. |
| 08 | Relay engaged during movement and disengaged at the end positions. |
| 09 | Service interval In signal. |
| 10 | Flashing during start-up/pre-warning only when closing. |
For parameters 01–10, menu 25 is activated for the external relay and menu 20 for the internal relay. The pre-warning is effective only when menu 32 is activated. Therefore, always check a relay change together with the associated menu that is automatically selected.
Menus 32, 34 and 35 – time settings
| Menu 32 parameter | Time / function |
|---|---|
| 00 | off |
| 01 | 1 s |
| 02 | 2 s |
| 03 | 3 s |
| 04 | 4 s |
| 05 | 5 s |
| 06 | 10 s |
| 07 | 15 s |
| 08 | 20 s |
| 09 | 30 s |
| 10 | 60 s |
| Menu 34 parameter | Time / function |
|---|---|
| 00 | off |
| 01 | 5 s |
| 02 | 10 s |
| 04 | 30 s |
| 05 | 60 s |
| 06 | 90 s |
| 07 | 120 s |
| 08 | 180 s |
| 09 | 240 s |
| 10 | 300 s |
| Menu 35 parameter | Time / function |
|---|---|
| 00 | off |
| 01 | same as 34 |
| 02 | 5 min |
| 03 | 15 min |
| 04 | 30 min |
| 05 | 45 min |
| 06 | 60 min |
| 07 | 90 min |
| 08 | 120 min |
| 09 | 180 min |
| 10 | 240 min |
Activate automatic mode 34/35 only after teaching the photocell. When they are switched on, the preliminary warning 32/02 is set automatically to 2 seconds. A new command will stop the gate while it is closing automatically. Set partial opening in menu 36; if it is too close to the closed position, the unit will report error 1 and use the minimum permitted position.
Remote control via an external receiver
In this separate offer, the LineaMatic H is supplied without a radio receiver. To use remote control, add a suitable receiver and a compatible transmitter. The receiver used determines the remote-control memory and learning procedure.
- Disconnect the mains power and any battery, then connect the receiver according to its own instructions and the circuit-board diagram.
- For the wired receiver shown, connect GN to 20 (0 V/−), BN to 5 (+24 V DC), WH to 21 (impulse), and YE to 23 (partial opening). Include the receiver's current draw in the combined 250 mA limit.
- Connect the specified receiver with an HEI3 BiSecur plug to the corresponding connection; connect ESEI BiSecur to the system BUS socket. Do not use BUS as a general-purpose +/− power supply.
- Store the remote-control codes on the receiver according to its instructions. Then test the impulse, partial-opening and any other channel functions individually, with the area secured.
Keep the antenna wire away from metal objects. Gate-position monitoring requires a suitable bidirectional receiver and transmitter; 868 MHz frequency alone, or an arbitrary receiver, does not guarantee this function.
Drive factory reset
Resetting the drive to factory settings
A factory reset restores the settings and deletes the learned travel distances and forces. Then select type 03 again for the LineaMatic H and complete the learning procedure. Menu 10 is used to relearn the travel distance and forces separately. Remote controls paired with an external receiver must be deleted on the receiver according to its own instructions.
- Disconnect the mains power and emergency battery as shown. Secure the gate against movement.
- Press and hold the P button, then restore the mains power.
- Keep holding P while 8.8. and C are displayed, until U appears; then release it.
- Select the correct type 03 for the LineaMatic H and repeat the entire commissioning procedure. Check the external receiver, safety functions, times and forces.

Reference run after release or power failure
A reference run may be required if the position is unknown after a power failure or after the force limit has been triggered three times. The next impulse starts the run in the closing direction only, at reduced speed and without force limitation. The area must be secured; if it is not protected by a photocell or other device, the run may only be carried out while keeping the gate in view. After manually disengaging the drive without a power failure, disconnect the power once more after securing it so the new reference run is carried out as instructed.
Display diagnostics
| Display | Meaning / action |
|---|---|
| U | The drive has not been taught; carry out commissioning. |
| 8.8. | Drive startup; this does not necessarily indicate an error. |
| 1 s with flashing dot | Unable to set the reversal limit or partial position; check for an obstruction and the distance from the closed position. |
| 2.1 / 2.2 / 2.3 | SE1 / SE2 / SE3 protection: obstruction, misalignment, wiring or device damage. |
| 3 / 5 | Force limit reached while closing / opening; remove the obstruction and check mechanical movement—do not automatically increase the force. |
| 4 | HALT12–13 interrupted; check the NC circuit and wiring. |
| 6 | System error or run-time limit reached; check the reset and repeat the learning procedure; if the drive is faulty, arrange repair or replacement. |
| 7 | Communication error on the additional circuit board; check the wiring, connectors and module. |
| 8 | Invalid entry or control command; check the selected value. |
| 9 | Triggered/fault in the tested safety device or 8k2; remove the obstruction and check the safety device. |
| 13 / 17 | Undervoltage / voltage error; check the power supply and battery. |
| C | Reference point unknown; secure the area and carry out a reference run. |
| In | Service interval has elapsed; have the assembly inspected. |
Maintenance and safe handover
The manufacturer describes the drive as maintenance-free, but the complete gate requires regular inspection. Check safety and protective functions monthly, and check 8k2 resistance edges and untested protective devices every six months as instructed. Check that the gate moves easily, the rack is secure, the guide is sound, cables are undamaged, photocells are clean, and the release mechanism works. Rectify any defects immediately.
Before maintenance, disconnect all power sources and prevent them from being switched on again. After installation and any changes, check the effectiveness of the protective devices, reversal and operating forces. Train the user, hand over the instructions and attach the warning label where it is clearly visible on the gate. Children must not play in the movement area; cross only after the gate has come to a complete stop.
Technical specifications of Hörmann LineaMatic H 4554321
| Parameter | Value |
|---|---|
| Model / type selection | LineaMatic H /03 |
| Maximum gate width | 10000 mm |
| Max. weight – ground-supported / cantilever | 800 kg /600 kg |
| Mains supply | 230/240 V AC,50/60 Hz; permitted range 170–260 V AC. |
| Control voltage | 24 V/37 V DC, switchable internal control; not a universal output for accessories. |
| Accessory power supply | 24 V DC;5=plus,20=0 V; total max.250 mA. |
| Radio control | The external receiver is selected separately; wiring and memory depend on its instructions. |
| Protection rating / temperature | IP44 /−20 to+60 °C |
| Maximum humidity | 93%, non-condensing |
| Standby power consumption | Less than 0.5 W |
| End positions | Magnetic REED sensor and electronically learned positions/forces. |
| Cycles per day/hour | As stated on the rating plate. |
| Housing | Weather-resistant metal casting and glass-fibre-reinforced plastic. |

The dimensioned drawing shows a housing measuring 193 × 253 × 256 mm. When installed on the floor plate, the total height can be adjusted up to 327 mm; the plate shown has a footprint of 260 × 295 mm. Choose the specific mounting height relative to the rack according to dimension A, not just the outer dimensions of the cover.
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]