Drive kit for sliding gates up to 800 kg CAME BXV08AGS, 801MS-0210 (D)


Product availability: within 3 days

We usually dispatch goods within 3 days.


Drive kit for sliding gates up to 800 kg CAME BXV08AGS, 801MS-0210 (D) Drive kit for sliding gates up to 800 kg CAME BXV08AGS, 801MS-0210 (D)
CAME-BXV08AGS-D
within 3 days
€496.52 excluding VAT
€610.72 including VAT

 pcs
Weight
12 kg

Description of Drive kit for sliding gates up to 800 kg CAME BXV08AGS, 801MS-0210 (D)

CAME BXV08AGS gate operator is designed for sliding gates weighing up to 800 kg and gate leaf length up to 20 m. It has an electromechanical stop switch. The operator is non-reversible. Detailed technical specifications ». Download the manual ».

CAME BXV08AGS with ZN7 control board is a sliding gate operator with a 24 V DC motor and mechanical limit switches. The mains supply is 230 V AC. It is designed for a gate leaf weighing up to 800 kg and 20 m long. Consider the gate’s weight, length, and resistance together; greater power does not make up for a gate that is difficult to move by hand.

Disconnect the mains supply and any batteries before carrying out work. Photocells and the encoder do not replace mechanical stops, protection of hazardous areas, or verification of forces on the completed gate.

Before installation, check the operator label, the ZN7 board, the H1 version, and its menu. The technical data and wiring diagrams below apply to the version described. The following settings apply to the version with F28 = 60–100%, F8 = 1/2, and U3 = 0/1. If the board has different values or connectors, use the manual for that specific version; these three items alone do not identify the entire firmware.

Quick navigation
BXV08AGS kitAccessories
InstallationWiring
Manual releaseBoard layout
Terminals and power supplyPhotocells and testing
Initial startupTravel learning
ProgrammingRemote controls
Reset and memoryTroubleshooting
Maintenance and servicingTechnical specifications
Installation manual (PDF)

CAME BXV08AGS kit

Both kits include an operator, remote control, photocells, radio receiver, and flashing light. Before wiring, check the markings on the accessories actually supplied. Choose additional components, especially the rack and local controls, to suit the specific gate.

FeatureCAME BXV08AGS
KitCAME BXV08AGS kit
CAME BXV08AGS, 801MS-0210 (D)
Maximum gate leaf weight800 kg
Maximum gate leaf length20 m
Mains / motor230 V AC / 24 V DC
Power / force400 W / 800 N
Maximum speed11 m/min
Motor selection A13–800 kg
Control system covered by this manualZN7, display and menu

The 18 or 20 m figure indicates the maximum gate leaf length, not necessarily the clear opening width. A1 selection does not change the load capacity of the physical operator.

Accessories and wiring examples

The following examples refer to specific, labelled devices. For other models, use their own terminals and settings; matching function or frequency alone does not confirm compatibility.

ComponentVerified example / application
PhotocellsCAME DIR10, 12/24 V AC/DC, range 10 m; wiring and TS test.
Flashing lightCAME KLED24, 24 V AC/DC, 2 W; 10–E output.
Radio receiverCAME AF43S, AF plug-in card, 433.92 MHz; verify the coding together with U4.
Remote controlCAME TOP-432EE, fixed code, 433.92 MHz; example for a compatible receiver.
RackRacks, module 4; clearance and fixing.
Local controlsSwitches, push buttons, and readers; NO commands and NC safety contacts according to the terminal layout.

Operator installation

With the operator released, the gate must move easily along its entire travel, without slopes, damaged wheels, or any risk of coming off its track. Check that mechanical stops are securely fixed in both the open and closed positions, that the base is stable, and that areas where the gate leaf could trap someone are protected. Water must not collect in the operator area or be directed at it in a stream. If the sliding gate leaf has a built-in pedestrian gate, motorized operation must only be possible when it is securely closed.

Foundation and anchor plate

The installation example has an excavation measuring 400 × 240 mm and 800 mm deep. Adjust the foundation dimensions to suit the ground conditions and the specific gate. The formwork extends 50 mm above ground level; use reinforcement and M12 anchors. A Ø 40 mm conduit is recommended for the operator supply cable, Ø 25 mm for accessories, and Ø 20 mm for any manual release cable.

Example foundation and conduit routing for BXV
Example foundation and conduit routing for BXV
Formwork 50 mm above ground level and reinforcement for the concrete foundation
Formwork 50 mm above ground level and reinforcement for the concrete foundation

Set the anchor plate level, route the cables through its openings, and leave the threaded anchor sections above the surface. Allow the concrete to cure for at least 24 hours. Determine the position of the plate relative to the rack according to the drawing: the 95 mm horizontal offset and 106 mm height refer to the surfaces indicated in the section view. Do not confuse them with the foundation dimensions.

Anchor plate, holes, and M12 fixings
Anchor plate, holes, and M12 fixings
Position of the anchor plate relative to the BXV rack
Position of the anchor plate relative to the BXV rack

Installation and height adjustment

Remove the cover and mount the operator on the plate. The cables must pass through the underside of the housing and the correctly fitted cable glands. While adjusting, raise the operator using its threaded feet by 5–10 mm, leaving room to adjust the meshing clearance.

Mounting the BXV operator on the plate
Mounting the BXV operator on the plate
Cable gland and height adjustment of the BXV operator
Cable gland and height adjustment of the BXV operator

Rack and meshing clearance

Release the operator and fit the rack while moving the gate leaf by hand. When joining the sections, place a spare rack section under the joint so that the teeth align smoothly. After installation, adjust the operator’s vertical and horizontal position.

Installing the BXV rack
Installing the BXV rack

Leave a clearance of 1–2 mm between the rack and pinion. The gate must not rest on the drive. Move the gate through its entire travel by hand, check the mesh and rack joints, and only then tighten the nuts and washers on the anchors.

1–2 mm clearance and BXV mesh adjustment
1–2 mm clearance and BXV mesh adjustment

Mechanical limit switches

Move the gate leaf manually to the open position. Attach the opening switch stop to the rack so that its ramp reliably actuates the spring-loaded microswitch. Set the closing stop in the same way. Secure the stops firmly; the gate’s fixed mechanical stop and the drive’s switch stop serve different purposes.

In the illustrated setup, leave approximately 20 mm before the fixed stop. Check the run-on distance at the actual speed and under load.

Mechanical switch stop at the opening position
Mechanical switch stop at the opening position
Mechanical switch stop at the closing position
Mechanical switch stop at the closing position

Wiring

ConnectionCable / requirement
230 V AC mains, L/N/PE3G × 1.5 mm² up to 20 m; 3G × 2.5 mm² for 20–30 m.
Control devicesNumber of conductors depends on the control setup; 0.5 mm² cross-section for the short runs listed.
DIR10 photocellsTX: 2 × 0.5 mm²; RX: 4 × 0.5 mm². Ensure the TX connection and NC contact are wired correctly.
AntennaRG58, maximum 10 m; 5 m or less recommended.
RSE / CRPUTP CAT 5; separate serial connection, not motor power.

The number of conductors must support the complete selected wiring diagram. For longer runs, simultaneous loads, or other accessories, calculate the cross-section based on current and voltage drop. Protect cables from damage and contact with the motor or transformer; route the mains supply and low-voltage circuits with appropriate separation.

Manual release in the event of a power failure

Disconnect the power and secure the gate leaf before moving it manually. Releasing a damaged or unbalanced gate can cause uncontrolled movement.

  1. Insert the key into the lock and turn it in the direction of the arrow shown in the illustration.
  2. Pull and open the release lever as shown in the illustration.
  3. Move the gate manually in a controlled manner, keeping people clear of its path.
  4. To re-engage the drive, return the lever to its original position and lock the mechanism. Before issuing a motor command, check that the drive is engaged.
Manual release and re-engagement of the BXV
Manual release and re-engagement of the BXV

Overview of the ZN7 control board

The ZN7 has a display and ESC, arrow, and ENTER buttons. Settings, timings, and users are managed through the menu. The AF, Memory Roll, R700/R800, RSE, and RIOCN8WS connectors each serve a specific purpose; insert or remove a card only when both the mains and batteries are disconnected.

Display, terminals, and connectors on the ZN7 control board
Display, terminals, and connectors on the ZN7 control board

Figure numberComponent
1 / 2 / 3Motor / encoder / limit switches
4 / 5 / 6Commands and safety / antenna / AF
7 / 8 / 9 / 10Memory Roll / R700 or R800 / RSE / RIOCN8WS
11 / 12Display / programming buttons
13 / 14 / 15A–B–GND serial connection / A–B keypad / S1–GND transponder
16 / 17 / 18GSM module / RGP1 / accessories and lights
19 / 20 / 21 / 22Accessory fuse / board input / mains fuse / mains supply

ZN7 terminals and power supply

TerminalsFunction / voltage / polarity
L / N / PE230 V AC mains, 50/60 Hz for BXV08AGS. PE is the protective conductor; AC has no +/− polarity.
10 / 11Accessories: normally 24 V AC, in battery operation 24 V DC, total load maximum 40 W. For DC 10 = plus (+), 11 = minus (−); no polarity for AC.
10 / EFlashing light or cycle light, 24 V AC/DC, max. 25 W. For DC, 10 is the positive common terminal and E is the switched output.
10 / 5Gate status indicator, 24 V AC/DC, max. 3 W. For DC, 10 is the positive common terminal and 5 is the switched output; it is not a permanent power supply.
24 / 0Internal supply to the board from the power section; do not connect it as an accessory output or external battery input.
M / N24 V DC motor; retain the wiring for the correct assembly. Not a 230 V supply.
+ / E / −Encoder: +/− power supply and E signal; not a general-purpose accessory output.
F / FA, F / FCF common, FA open, FC close; NC limit contacts, no polarity.
A / B / GND – RSESerial interface with the RSE card; do not confuse it with the A/B keypad terminals.

ZN7 accessory power output, 10 (+) and 11 (−) for DC
ZN7 accessory power output, 10 (+) and 11 (−) for DC

Commands and safety contacts

TerminalsContact / function
1–2NC STOP; set F1 = ON if connected. Factory setting: F1 = OFF. No polarity.
2–7NO command; function selected by F7. Voltage-free contact, no polarity.
2–3PNO partial or full opening, as set by F8. Voltage-free contact, no polarity.
2–CX / 2–CYNC safety inputs; configure F2/F3. No polarity.
10 / TSTested photocell power supply branch as shown in the diagram; do not activate F5 unless wired correctly.
A–B / R800Code keypad with R800 decoding card, F14 = 1.
S1–GND / R700Transponder or reader with R700, F14 = 0.
Antenna / AFRG58 and plug-in radio card with the correct frequency/coding.

STOP, commands, reader and keypad on ZN7
STOP, commands, reader and keypad on ZN7

Flashing light and status indicator

KLED24, 24 V AC/DC and 2 W, connect to 10–E; set the flashing light to F18 = 0. KLED24 does not have a separately marked +/− supply connection. With AC, there is no DC polarity; with DC, 10 is the board's positive common terminal. Do not connect a 230 V flashing light to this 24 V output.

Output 10–5 is for a small status indicator, max. 3 W, with setting F10. Cycle-light mode F18 = 1 requires an automatic closing time; the light stays on from opening until fully closed, including during the waiting period.

Light, flashing light and status indicator on ZN7
Light, flashing light and status indicator on ZN7
Wiring the CAME KLED24 24 V flashing light
Wiring the CAME KLED24 24 V flashing light

Photocells and safety test

CAME DIR10 consists of a TX transmitter and RX receiver with a range of 10 m. Set the receiver jumper to 24 V. The pair draws 60 mA at 24 V AC. The RX power terminals are marked 10 (+), 2 (−); TX has terminals TX and 2; the manufacturer does not separately mark +/− beside them in this diagram. With AC power, DC polarity does not apply. The TX terminal is part of the synchronisation circuit; connect RX TX to TX TX as shown in the diagram and do not replace this connection with a direct feed from board terminal 10.

CAME DIR10 photocell TX and RX terminals
CAME DIR10 photocell TX and RX terminals
DIR10 jumper for 12 or 24 V power supply
DIR10 jumper for 12 or 24 V power supply

Photocell terminalStandard wiringWiring with test
RX 10 (+)Board 10Board 10
RX 2 (−) and RX CBoard 2Board 2
RX TX ↔ TX TXConnect TX between the receiver and transmitterSame connection
TX 2Board 2Board TS
RX NCBoard CXBoard CX

C–NC is a volt-free safety contact. It has no positive or negative polarity. The power supply wiring and the contact wiring are two separate circuits. With DC, 10 is positive; the RX 2 negative terminal is connected to the board's common terminal 2 in this specific diagram. Do not confuse terminal 2 with power supply terminal 11.

For a contact on CX, set F2 = C1. For a contact on CY, select the corresponding response using F3. C1 reopens during closing, C2 recloses during opening, C3 stops and then closes automatically and requires F19; C4 waits for the obstruction to be removed and then resumes movement.

Standard wiring of synchronised photocells on ZN7
Standard wiring of synchronised photocells on ZN7

Test wiring via TS

For the test, TX 2 is moved to TS, while RX 2 and RX C remain connected to board terminal 2. The TX connection between the transmitter and receiver remains in place. First change the wiring with the power off, and only then activate the test.

Set F5 = 1 for CX, 2 for CY, or 4 for both CX and CY. If the test fails, E4 is displayed and the operator will not execute the command. This function is used with active safety inputs.

Wiring synchronised photocells with TS test on ZN7
Wiring synchronised photocells with TS test on ZN7

After wiring, test by interrupting the beam during the relevant movement and then clearing it. Do not bridge the safety input as a permanent fix for a fault.

Safety edges

Connect the NC contact edge between 2 and CX or CY and select C7—reopening during closing—or C8—reclosing during opening. A volt-free contact has no polarity. Do not connect a resistive edge as an ordinary NC contact; it must have an interface suitable for the specific controller.

Initial ZN7 startup

  1. Check that the gate moves freely, the rack and fixed and switching limit stops are secure, the operator is engaged, the wiring is correct, and hazardous areas are protected.
  2. Switch on the power and check the display. Set A1 = 3 for a motor up to 800 kg, F54 according to the direction and F1 according to the connected STOP input.
  3. Set F2/F3 for the connected safety devices and, if applicable, the F5 test. Leave unused inputs deactivated. For learning, F11 must be ON.
  4. Run A3 – travel learning.
  5. Set the operating parameters and users, then test a complete cycle, partial opening, each safety device, the flashing light, and behaviour after a power failure.

The first normal manoeuvre after switching on the power is opening; wait for it to finish. A3 calibration has its own sequence. If you notice unusual noise, vibration or incorrect direction, stop immediately using ESC/STOP and resolve the cause.

A3 – automatic travel learning

Prerequisites: correct A1 and F54 settings, STOP configured, encoder active, and limit switches and fixed stops correctly set. Move the gate manually to approximately halfway and re-engage the operator. The area must remain clear.

During calibration, the safety devices are disabled, except for stopping with the ESC button. Monitor the entire movement and keep people out of the travel path.

  1. Press ENTER, use the arrows to select A3, then confirm with ENTER.
  2. Select ON and confirm with ENTER.
  3. The operator first closes to the end position; the display shows CL1.
  4. It then opens to the end position; the display shows OP1.
  5. When complete, check the full movement and the safety devices. For E1/E2, first resolve the cause according to the diagnostics; do not repeat the learning process due to a mechanical fault.
Calibration ZN7 – closing CL1 and opening OP1
Calibration ZN7 – closing CL1 and opening OP1

Programming using the display

Program while the drive is stopped. ENTER opens the menu and confirms the selection; arrows </> select an item or change a value. After making a change, press ENTER to confirm. ESC cancels an unconfirmed change, goes back, or exits the menu. During normal operation, ESC stops the drive; the arrows allow test movement.

ESC, arrow and ENTER buttons on the ZN7
ESC, arrow and ENTER buttons on the ZN7

Factory-set values for the listed menu are shown in bold. Accessory functions appear only when the required card is installed or a related function is active. Make a note of the current settings before changing them. A lower F34/F35 sensitivity value means higher sensitivity; after changing the speed, torque, or sensitivity, check the forces and safety devices.

F functions

Function and descriptionValues / factory setting
F1 – Full stop
NC input 1–2. STOP disables automatic closing; resume with a new command. Leave OFF if no STOP device is connected.
OFF
ON
F2 – CX input
Contact 2–CX; select according to the photocell or safety edge. C3 requires F19.
OFF – disabled
C1 – reopen while closing
C2 – close again while opening
C3 – stop, then close automatically
C4 – wait for the obstacle to be removed, then resume
C7 – safety edge: reopen while closing
C8 – safety edge: close again while opening
F3 – CY input
Contact 2–CY; second independent safety input. C3 requires F19.
OFF – disabled
C1 – reopen while closing
C2 – close again while opening
C3 – stop, then close automatically
C4 – wait for the obstacle to be removed, then resume
C7 – safety edge: reopen while closing
C8 – safety edge: close again while opening
F5 – Photocell test
The tested circuit must be wired through TS. Testing is always active for wireless devices.
0 – disabled
1 – CX
2 – CY
4 – CX and CY
F6 – Hold-to-run control
The drive stops when the button is released; all other control devices are disabled. Use only with attended control; test to verify the direction of each button.
0 – disabled
1 – enabled
F7 – Command 2–7
Assigns an action to a wired command.
0 – open – close – reverse direction
1 – open – STOP – close – STOP
2 – open only
3 – close only
F8 – Command 2–3P
With the encoder enabled, partial opening is set by F36; with it disabled, by F71.
1 – open partially
2 – open fully
F9 – Obstacle detection when the motor is stopped
When the gate is open, closed, or fully stopped, movement is prevented if the safety device detects an obstacle.
OFF
ON
F10 – Gate status indicator
Output 10–5, 24 V AC/DC, max. 3 W.
0 – on when the gate is open and while it is moving
1 – flashes every 0.5 s while opening and every 1 s while closing; on when open, off when closed
F11 – Encoder
Controls deceleration, obstacle detection, and sensitivity.
ON – enabled
OFF
F12 – Slow start
The gate moves at a slow speed for the first few seconds after a command.
OFF
ON
F14 – Sensor type
Access device with the corresponding decoder card.
0 – transponder / card reader with R700
1 – keypad with R800
F18 – Light 10–E
Output 24 V AC/DC, max. 25 W. Cycle lighting requires automatic closing to be set.
0 – flashing light while moving
1 – cycle lighting from opening until fully closed, including during the waiting period
F19 – Automatic closing
Waiting time after fully opening. It is not activated after a full STOP, a power failure, or activation of an obstacle-detecting safety device.
OFF – disabled
1 to 180 s
F20 – Closing after partial opening
Requires F19 to be enabled; the same restrictions apply in the event of a STOP, power failure, or obstacle.
OFF
1 to 180 s
10 s – factory setting
F21 – Pre-flashing
Flashing light duration before movement.
OFF
1 to 10 s
F28 – Opening speed
Percentage of the maximum opening speed; after changing it, check the full movement cycle and safety.
60 to 100 %
100 % – factory setting
F30 – Deceleration speed
Deceleration while opening and closing; only with the encoder enabled.
10 to 50 %
50 % – factory setting
F34 – Travel sensitivity
Obstacle detection during normal movement. A lower value means higher sensitivity.
10 to 100 %
10 % – highest sensitivity
100 % – lowest sensitivity
F35 – Deceleration sensitivity
Only with the encoder enabled; check the forces after changing the setting.
10 to 100%
10% – highest sensitivity
100% – lowest sensitivity
F36 – Partial opening point
Percentage of the total travel; only with the encoder enabled.
10 to 80%
10% – factory setting
F37 – Deceleration point during opening
Deceleration start as a percentage of the total travel; only with the encoder.
10 to 60%
25% – factory setting
F38 – Deceleration point during closing
Deceleration start as a percentage of the total travel; only with the encoder.
10 to 60%
25% – factory setting
F49 – RSE serial interface
Requires a card in the RSE connector.
0 – off
1 – paired drives
3 – CRP communication
F50 – Save data
Users, times and configuration to Memory Roll; this function is displayed only when memory is inserted.
0 – do not execute
1 – save
F51 – Load data
Load saved data from Memory Roll; this function is displayed only when memory is inserted.
0 – do not execute
1 – load
F52 – MASTER → SLAVE transfer
Transfer parameters to the second drive; only with paired RSE.
OFF
ON – transfer
F54 – Opening direction
Select according to the actual installation.
0 – left
1 – right
F56 – CRP address
Unique board address when multiple drives are connected to CRP.
1 to 255
F63 – Serial communication speed
Set to match the connected system.
0 – 1,200 bps
1 – 2,400 bps
2 – 4,800 bps
3 – 9,600 bps
4 – 14,400 bps
5 – 19,200 bps
6 – 38,400 bps
7 – 57,600 bps
8 – 115,200 bps
F65 – RIO ED T1
First wireless safety edge; only with the appropriate RIO interface.
OFF
P0 – STOP, no automatic closing; resume with a new command
P7 – reopen during closing
P8 – reclose during opening
F66 – RIO ED T2
Second wireless safety edge; check channel T2 and this setting on the display.
OFF
P0 – STOP, no automatic closing; resume with a new command
P7 – reopen during closing
P8 – reclose during opening
F67 – RIO PH T1
First wireless photocells; only with the RIO interface. P3 requires automatic closing.
OFF
P1 – reopen during closing
P2 – reclose during opening
P3 – partial stop with automatic closing
P4 – wait for the obstacle to be removed
F68 – RIO PH T2
Second wireless photocells; only with the RIO interface. P3 requires automatic closing.
OFF
P1 – reopen during closing
P2 – reclose during opening
P3 – partial stop with automatic closing
P4 – wait for the obstacle to be removed
F71 – Partial opening time
Used when encoder F11 is off; when the encoder is enabled, set F36.
5 to 40 s

Users and system U / A / H

Function and meaningOptions / confirmation
U1 – Add a user
Pairing a remote control/access device; up to 250 users.
1 – step-by-step
2 – sequential
3 – open only
4 – partial opening
U2 – Delete one user
Select the memory slot number using the arrows or activate the relevant remote control; ENTER confirms, and CLr indicates deletion.
OFF
ON – select and delete a user
U3 – Delete all users
Deletes all stored users.
0 – do not execute
1 – delete
U4 – Radio coding
Selecting 2 or 3 removes stored transmitters with a different coding. Record the users and check the control unit version before confirming.
1 – all supported coding types
2 – Rolling Code
3 – TWIN / TW key block
A1 – Motor type
For BXV08AGS, the value must be 3. Another selection does not change the physical motor's load capacity.
1 – 400 kg
2 – 600 kg
3 – 800 kg
4 – 1,000 kg
A3 – Travel learning
Starts automatic calibration.
OFF
ON – start
A4 – Reset parameters
Restores factory settings and erases the learned travel limits. Reconfigure and check safety before operation.
OFF
ON – execute
A5 – Operation counter
Displays the number of individual movements; this is not the number of complete open/close cycles.
001 = 100 operations
010 = 1,000
100 = 10,000
999 = 99,900
CSI = service intervention
A6 – Motor torque
Set according to the mechanics; after changing it, measure the forces and verify the safety devices.
1 – minimum to 5 – maximum
H1 – Firmware version
Display the FW and GUI versions; record them for servicing and to verify the model variant.
Display version

Pairing and deleting remote controls

The ZN7 memory has a capacity of 250 users. The receiver must be installed in the AF slot and match the transmitter's frequency and coding. An example of a 433.92 MHz fixed code is TOP-432EE with AF43S. U4 can restrict the range of supported coding types; matching frequency alone is not enough.

  1. In U1, select the operation: 1 step-by-step, 2 sequential, 3 open only, or 4 partially open.
  2. Press ENTER to confirm, then send the code by pressing the selected button on the remote control.
  3. Repeat the procedure for the next user. Record the stored numbers and their assigned commands, then test the actual operation.

To delete a single user, use U2: select ON, choose the number using the arrow keys or activate the corresponding stored transmitter, then press ENTER to confirm. The display shows CLr to confirm deletion. U3 = 1 deletes all users.

U4 = 2 (Rolling Code) or 3 (TWIN) deletes previously stored transmitters using a different coding type. Before making changes, verify the system, H1 version, and remote-control records; do not use this setting to troubleshoot a receiver fault.

Backup using Memory Roll

  1. Disconnect the mains and any batteries, then insert the Memory Roll into its connector.
  2. Switch on the power; use F50 = 1 to save the data and F51 = 1 to load it. Loading replaces the board's data with the saved data.
  3. When finished, disconnect the power again and remove the memory card.
  4. After loading, verify the model, direction, safety devices, and all commands. This ZN7 has a Memory Roll connector; do not look for a nonexistent USB port.

Pairing two drives

An RSE card is used on each board, with a CAT 5 connection via A–B–GND as shown in the diagram. Connect the control and safety devices to the MASTER board. On that board, set F49 = 1, the direction in F54, and parameter transfer in F52. Store users on the MASTER; partial opening and the step-by-step command operate as shown for the combined system.

RSE and MASTER–SLAVE connection for two BXV drives
RSE and MASTER–SLAVE connection for two BXV drives

RIO wireless safety system

RIOCN8WS uses a dedicated RIO connector. F65/F66 set two wireless safety edges, and F67/F68 set two photocell channels. Check the actual item and channel displayed on the screen. The wireless safety test remains active; resolve a connection loss (E17) or missing configuration (E18) before resuming operation.

A4 – Reset parameters

Before resetting, record the H1 version, settings, and users; if you have a Memory Roll, save the data. In A4, select ON and press ENTER to confirm. For the model variant described here, the factory settings are restored and the travel learning is erased.

After resetting, reconfigure A1, F54, F1, the safety inputs, and A3 travel learning. Verify the safety devices before normal operation. Deleting users is a separate function, U3. On a board with a different menu, A4 may restore a different range of settings; follow the instructions for that specific model variant.

Display-based diagnostics

CodeMeaning / check
E1Calibration error. Check A3, the mechanics, direction, and limit switches.
E2Configuration error. Verify model A1, direction F54, and that travel learning is complete.
E3Encoder error. With the power off, check the +/E/− connector and wires; after repair, perform travel learning.
E4Safety test error. Check TX on TS, power supply, NC, and F5.
E7Operating time exceeded. Check resistance, stops, and that the movement completes.
E9Obstacle while closing. Remove the actual obstruction; check the rack and sensitivity.
E10Obstacle while opening. Check the travel path and that the force settings are correct.
E11Too many consecutive obstructions. Repair the mechanics or resolve the cause of the safety device activation.
E13Both limit contacts are open. Check FA/FC/F and the switching stops.
E14Serial communication error. Check RSE, CAT 5, and configuration.
E15Incompatible transmitter. Check AF, frequency, and U4.
E17Wireless system communication fault. Check RIO, devices, and interference.
E18Wireless system is not configured. Verify RIO and the relevant F65–F68 settings.

If the gate does not move, check the power supply, drive release, STOP input and active safety inputs, a button that is stuck on, and the transmitter battery. If it opens but does not close, check the photocells and their NC contact. Do not bypass a safety device fault with a permanent jumper.

ZN7 fuses for 230 V

CircuitFast-blow fuse
Mains LINE1.6 A-F
Accessories2 A-F

Check fuses with the mains and batteries disconnected. Replace only with a fuse of the same rating and type; first eliminate the cause of the short circuit or overload.

Maintenance and servicing

Regularly check that the travel path and rack are clean, the gate moves easily by hand, the drive is securely fastened, the switching stops and cables are in good condition, the manual release works, and all safety devices function correctly. Disconnect the mains and battery backup before cleaning or carrying out any work. If there is damage, unusual noise, or vibration, stop operation and resolve the cause.

Set torque A6 and sensitivity F34/F35 according to the actual mechanics; do not mask resistance or a fault by increasing the torque. After adjustment or servicing, verify the full movement, forces, and safety devices. Record H1, the number of manoeuvres in A5, and any repairs. Give the user the instructions for the complete system and demonstrate the manual release. Take electronic components and batteries to a designated collection point for disposal.

Technical specifications of the CAME BXV08AGS

ParameterValue
Maximum gate leaf weight800 kg
Maximum gate leaf length20 m
Mains power supply to the drive230 V AC, 50/60 Hz
Motor power supply24 V DC
Power400 W
Thrust800 N
Maximum travel speed11 m/min
Maximum current – according to the manufacturer's technical data sheet16 A
Protection ratingIP44
Operating temperature−20 to +55 °C
OperationIntensive use; this is not a fixed number of cycles per hour.
Operating time180 s
Standby power consumption5.5 W
Protection classI
Rack / limit switchesModule 4 / mechanical
Cover colourGrey RAL 7024
Control unit in this manualZN7, display and ESC/arrows/ENTER
Setting A13 – 800 kg
Body dimensions (width × depth × height)290 × 212 × 363 mm
Anchor plate300 × 170 mm; spacing as shown in the drawing

Dimensioned drawing of the CAME BXV08AGS drive
Dimensioned drawing of the CAME BXV08AGS drive

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about Drive kit for sliding gates up to 800 kg CAME BXV08AGS, 801MS-0210 (D)

Product: Drive kit for sliding gates up to 800 kg CAME BXV08AGS, 801MS-0210 (D)
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.