Description of Drive kit for sliding gates up to 800 kg CAME BXV08AGS, 801MS-0210 (D)
CAME BXV08AGS gate operator is designed for sliding gates weighing up to 800 kg and gate leaf length up to 20 m. It has an electromechanical stop switch. The operator is non-reversible. Detailed technical specifications ». Download the manual ».
CAME BXV08AGS with ZN7 control board is a sliding gate operator with a 24 V DC motor and mechanical limit switches. The mains supply is 230 V AC. It is designed for a gate leaf weighing up to 800 kg and 20 m long. Consider the gate’s weight, length, and resistance together; greater power does not make up for a gate that is difficult to move by hand.
Disconnect the mains supply and any batteries before carrying out work. Photocells and the encoder do not replace mechanical stops, protection of hazardous areas, or verification of forces on the completed gate.
Before installation, check the operator label, the ZN7 board, the H1 version, and its menu. The technical data and wiring diagrams below apply to the version described. The following settings apply to the version with F28 = 60–100%, F8 = 1/2, and U3 = 0/1. If the board has different values or connectors, use the manual for that specific version; these three items alone do not identify the entire firmware.
CAME BXV08AGS kit
Both kits include an operator, remote control, photocells, radio receiver, and flashing light. Before wiring, check the markings on the accessories actually supplied. Choose additional components, especially the rack and local controls, to suit the specific gate.
| Feature | CAME BXV08AGS |
|---|---|
| Kit | ![]() CAME BXV08AGS, 801MS-0210 (D) |
| Maximum gate leaf weight | 800 kg |
| Maximum gate leaf length | 20 m |
| Mains / motor | 230 V AC / 24 V DC |
| Power / force | 400 W / 800 N |
| Maximum speed | 11 m/min |
| Motor selection A1 | 3–800 kg |
| Control system covered by this manual | ZN7, display and menu |
The 18 or 20 m figure indicates the maximum gate leaf length, not necessarily the clear opening width. A1 selection does not change the load capacity of the physical operator.
Accessories and wiring examples
The following examples refer to specific, labelled devices. For other models, use their own terminals and settings; matching function or frequency alone does not confirm compatibility.
| Component | Verified example / application |
|---|---|
| Photocells | CAME DIR10, 12/24 V AC/DC, range 10 m; wiring and TS test. |
| Flashing light | CAME KLED24, 24 V AC/DC, 2 W; 10–E output. |
| Radio receiver | CAME AF43S, AF plug-in card, 433.92 MHz; verify the coding together with U4. |
| Remote control | CAME TOP-432EE, fixed code, 433.92 MHz; example for a compatible receiver. |
| Rack | Racks, module 4; clearance and fixing. |
| Local controls | Switches, push buttons, and readers; NO commands and NC safety contacts according to the terminal layout. |
Operator installation
With the operator released, the gate must move easily along its entire travel, without slopes, damaged wheels, or any risk of coming off its track. Check that mechanical stops are securely fixed in both the open and closed positions, that the base is stable, and that areas where the gate leaf could trap someone are protected. Water must not collect in the operator area or be directed at it in a stream. If the sliding gate leaf has a built-in pedestrian gate, motorized operation must only be possible when it is securely closed.
Foundation and anchor plate
The installation example has an excavation measuring 400 × 240 mm and 800 mm deep. Adjust the foundation dimensions to suit the ground conditions and the specific gate. The formwork extends 50 mm above ground level; use reinforcement and M12 anchors. A Ø 40 mm conduit is recommended for the operator supply cable, Ø 25 mm for accessories, and Ø 20 mm for any manual release cable.


Set the anchor plate level, route the cables through its openings, and leave the threaded anchor sections above the surface. Allow the concrete to cure for at least 24 hours. Determine the position of the plate relative to the rack according to the drawing: the 95 mm horizontal offset and 106 mm height refer to the surfaces indicated in the section view. Do not confuse them with the foundation dimensions.


Installation and height adjustment
Remove the cover and mount the operator on the plate. The cables must pass through the underside of the housing and the correctly fitted cable glands. While adjusting, raise the operator using its threaded feet by 5–10 mm, leaving room to adjust the meshing clearance.


Rack and meshing clearance
Release the operator and fit the rack while moving the gate leaf by hand. When joining the sections, place a spare rack section under the joint so that the teeth align smoothly. After installation, adjust the operator’s vertical and horizontal position.

Leave a clearance of 1–2 mm between the rack and pinion. The gate must not rest on the drive. Move the gate through its entire travel by hand, check the mesh and rack joints, and only then tighten the nuts and washers on the anchors.

Mechanical limit switches
Move the gate leaf manually to the open position. Attach the opening switch stop to the rack so that its ramp reliably actuates the spring-loaded microswitch. Set the closing stop in the same way. Secure the stops firmly; the gate’s fixed mechanical stop and the drive’s switch stop serve different purposes.
In the illustrated setup, leave approximately 20 mm before the fixed stop. Check the run-on distance at the actual speed and under load.


Wiring
| Connection | Cable / requirement |
|---|---|
| 230 V AC mains, L/N/PE | 3G × 1.5 mm² up to 20 m; 3G × 2.5 mm² for 20–30 m. |
| Control devices | Number of conductors depends on the control setup; 0.5 mm² cross-section for the short runs listed. |
| DIR10 photocells | TX: 2 × 0.5 mm²; RX: 4 × 0.5 mm². Ensure the TX connection and NC contact are wired correctly. |
| Antenna | RG58, maximum 10 m; 5 m or less recommended. |
| RSE / CRP | UTP CAT 5; separate serial connection, not motor power. |
The number of conductors must support the complete selected wiring diagram. For longer runs, simultaneous loads, or other accessories, calculate the cross-section based on current and voltage drop. Protect cables from damage and contact with the motor or transformer; route the mains supply and low-voltage circuits with appropriate separation.
Manual release in the event of a power failure
Disconnect the power and secure the gate leaf before moving it manually. Releasing a damaged or unbalanced gate can cause uncontrolled movement.
- Insert the key into the lock and turn it in the direction of the arrow shown in the illustration.
- Pull and open the release lever as shown in the illustration.
- Move the gate manually in a controlled manner, keeping people clear of its path.
- To re-engage the drive, return the lever to its original position and lock the mechanism. Before issuing a motor command, check that the drive is engaged.

Overview of the ZN7 control board
The ZN7 has a display and ESC, arrow, and ENTER buttons. Settings, timings, and users are managed through the menu. The AF, Memory Roll, R700/R800, RSE, and RIOCN8WS connectors each serve a specific purpose; insert or remove a card only when both the mains and batteries are disconnected.

| Figure number | Component |
|---|---|
| 1 / 2 / 3 | Motor / encoder / limit switches |
| 4 / 5 / 6 | Commands and safety / antenna / AF |
| 7 / 8 / 9 / 10 | Memory Roll / R700 or R800 / RSE / RIOCN8WS |
| 11 / 12 | Display / programming buttons |
| 13 / 14 / 15 | A–B–GND serial connection / A–B keypad / S1–GND transponder |
| 16 / 17 / 18 | GSM module / RGP1 / accessories and lights |
| 19 / 20 / 21 / 22 | Accessory fuse / board input / mains fuse / mains supply |
ZN7 terminals and power supply
| Terminals | Function / voltage / polarity |
|---|---|
| L / N / PE | 230 V AC mains, 50/60 Hz for BXV08AGS. PE is the protective conductor; AC has no +/− polarity. |
| 10 / 11 | Accessories: normally 24 V AC, in battery operation 24 V DC, total load maximum 40 W. For DC 10 = plus (+), 11 = minus (−); no polarity for AC. |
| 10 / E | Flashing light or cycle light, 24 V AC/DC, max. 25 W. For DC, 10 is the positive common terminal and E is the switched output. |
| 10 / 5 | Gate status indicator, 24 V AC/DC, max. 3 W. For DC, 10 is the positive common terminal and 5 is the switched output; it is not a permanent power supply. |
| 24 / 0 | Internal supply to the board from the power section; do not connect it as an accessory output or external battery input. |
| M / N | 24 V DC motor; retain the wiring for the correct assembly. Not a 230 V supply. |
| + / E / − | Encoder: +/− power supply and E signal; not a general-purpose accessory output. |
| F / FA, F / FC | F common, FA open, FC close; NC limit contacts, no polarity. |
| A / B / GND – RSE | Serial interface with the RSE card; do not confuse it with the A/B keypad terminals. |

Commands and safety contacts
| Terminals | Contact / function |
|---|---|
| 1–2 | NC STOP; set F1 = ON if connected. Factory setting: F1 = OFF. No polarity. |
| 2–7 | NO command; function selected by F7. Voltage-free contact, no polarity. |
| 2–3P | NO partial or full opening, as set by F8. Voltage-free contact, no polarity. |
| 2–CX / 2–CY | NC safety inputs; configure F2/F3. No polarity. |
| 10 / TS | Tested photocell power supply branch as shown in the diagram; do not activate F5 unless wired correctly. |
| A–B / R800 | Code keypad with R800 decoding card, F14 = 1. |
| S1–GND / R700 | Transponder or reader with R700, F14 = 0. |
| Antenna / AF | RG58 and plug-in radio card with the correct frequency/coding. |

Flashing light and status indicator
KLED24, 24 V AC/DC and 2 W, connect to 10–E; set the flashing light to F18 = 0. KLED24 does not have a separately marked +/− supply connection. With AC, there is no DC polarity; with DC, 10 is the board's positive common terminal. Do not connect a 230 V flashing light to this 24 V output.
Output 10–5 is for a small status indicator, max. 3 W, with setting F10. Cycle-light mode F18 = 1 requires an automatic closing time; the light stays on from opening until fully closed, including during the waiting period.


Photocells and safety test
CAME DIR10 consists of a TX transmitter and RX receiver with a range of 10 m. Set the receiver jumper to 24 V. The pair draws 60 mA at 24 V AC. The RX power terminals are marked 10 (+), 2 (−); TX has terminals TX and 2; the manufacturer does not separately mark +/− beside them in this diagram. With AC power, DC polarity does not apply. The TX terminal is part of the synchronisation circuit; connect RX TX to TX TX as shown in the diagram and do not replace this connection with a direct feed from board terminal 10.


| Photocell terminal | Standard wiring | Wiring with test |
|---|---|---|
| RX 10 (+) | Board 10 | Board 10 |
| RX 2 (−) and RX C | Board 2 | Board 2 |
| RX TX ↔ TX TX | Connect TX between the receiver and transmitter | Same connection |
| TX 2 | Board 2 | Board TS |
| RX NC | Board CX | Board CX |
C–NC is a volt-free safety contact. It has no positive or negative polarity. The power supply wiring and the contact wiring are two separate circuits. With DC, 10 is positive; the RX 2 negative terminal is connected to the board's common terminal 2 in this specific diagram. Do not confuse terminal 2 with power supply terminal 11.
For a contact on CX, set F2 = C1. For a contact on CY, select the corresponding response using F3. C1 reopens during closing, C2 recloses during opening, C3 stops and then closes automatically and requires F19; C4 waits for the obstruction to be removed and then resumes movement.

Test wiring via TS
For the test, TX 2 is moved to TS, while RX 2 and RX C remain connected to board terminal 2. The TX connection between the transmitter and receiver remains in place. First change the wiring with the power off, and only then activate the test.
Set F5 = 1 for CX, 2 for CY, or 4 for both CX and CY. If the test fails, E4 is displayed and the operator will not execute the command. This function is used with active safety inputs.

After wiring, test by interrupting the beam during the relevant movement and then clearing it. Do not bridge the safety input as a permanent fix for a fault.
Safety edges
Connect the NC contact edge between 2 and CX or CY and select C7—reopening during closing—or C8—reclosing during opening. A volt-free contact has no polarity. Do not connect a resistive edge as an ordinary NC contact; it must have an interface suitable for the specific controller.
Initial ZN7 startup
- Check that the gate moves freely, the rack and fixed and switching limit stops are secure, the operator is engaged, the wiring is correct, and hazardous areas are protected.
- Switch on the power and check the display. Set A1 = 3 for a motor up to 800 kg, F54 according to the direction and F1 according to the connected STOP input.
- Set F2/F3 for the connected safety devices and, if applicable, the F5 test. Leave unused inputs deactivated. For learning, F11 must be ON.
- Run A3 – travel learning.
- Set the operating parameters and users, then test a complete cycle, partial opening, each safety device, the flashing light, and behaviour after a power failure.
The first normal manoeuvre after switching on the power is opening; wait for it to finish. A3 calibration has its own sequence. If you notice unusual noise, vibration or incorrect direction, stop immediately using ESC/STOP and resolve the cause.
A3 – automatic travel learning
Prerequisites: correct A1 and F54 settings, STOP configured, encoder active, and limit switches and fixed stops correctly set. Move the gate manually to approximately halfway and re-engage the operator. The area must remain clear.
During calibration, the safety devices are disabled, except for stopping with the ESC button. Monitor the entire movement and keep people out of the travel path.
- Press ENTER, use the arrows to select A3, then confirm with ENTER.
- Select ON and confirm with ENTER.
- The operator first closes to the end position; the display shows CL1.
- It then opens to the end position; the display shows OP1.
- When complete, check the full movement and the safety devices. For E1/E2, first resolve the cause according to the diagnostics; do not repeat the learning process due to a mechanical fault.

Programming using the display
Program while the drive is stopped. ENTER opens the menu and confirms the selection; arrows </> select an item or change a value. After making a change, press ENTER to confirm. ESC cancels an unconfirmed change, goes back, or exits the menu. During normal operation, ESC stops the drive; the arrows allow test movement.

Factory-set values for the listed menu are shown in bold. Accessory functions appear only when the required card is installed or a related function is active. Make a note of the current settings before changing them. A lower F34/F35 sensitivity value means higher sensitivity; after changing the speed, torque, or sensitivity, check the forces and safety devices.
F functions
Users and system U / A / H
Pairing and deleting remote controls
The ZN7 memory has a capacity of 250 users. The receiver must be installed in the AF slot and match the transmitter's frequency and coding. An example of a 433.92 MHz fixed code is TOP-432EE with AF43S. U4 can restrict the range of supported coding types; matching frequency alone is not enough.
- In U1, select the operation: 1 step-by-step, 2 sequential, 3 open only, or 4 partially open.
- Press ENTER to confirm, then send the code by pressing the selected button on the remote control.
- Repeat the procedure for the next user. Record the stored numbers and their assigned commands, then test the actual operation.
To delete a single user, use U2: select ON, choose the number using the arrow keys or activate the corresponding stored transmitter, then press ENTER to confirm. The display shows CLr to confirm deletion. U3 = 1 deletes all users.
U4 = 2 (Rolling Code) or 3 (TWIN) deletes previously stored transmitters using a different coding type. Before making changes, verify the system, H1 version, and remote-control records; do not use this setting to troubleshoot a receiver fault.
Backup using Memory Roll
- Disconnect the mains and any batteries, then insert the Memory Roll into its connector.
- Switch on the power; use F50 = 1 to save the data and F51 = 1 to load it. Loading replaces the board's data with the saved data.
- When finished, disconnect the power again and remove the memory card.
- After loading, verify the model, direction, safety devices, and all commands. This ZN7 has a Memory Roll connector; do not look for a nonexistent USB port.
Pairing two drives
An RSE card is used on each board, with a CAT 5 connection via A–B–GND as shown in the diagram. Connect the control and safety devices to the MASTER board. On that board, set F49 = 1, the direction in F54, and parameter transfer in F52. Store users on the MASTER; partial opening and the step-by-step command operate as shown for the combined system.

RIO wireless safety system
RIOCN8WS uses a dedicated RIO connector. F65/F66 set two wireless safety edges, and F67/F68 set two photocell channels. Check the actual item and channel displayed on the screen. The wireless safety test remains active; resolve a connection loss (E17) or missing configuration (E18) before resuming operation.
A4 – Reset parameters
Before resetting, record the H1 version, settings, and users; if you have a Memory Roll, save the data. In A4, select ON and press ENTER to confirm. For the model variant described here, the factory settings are restored and the travel learning is erased.
After resetting, reconfigure A1, F54, F1, the safety inputs, and A3 travel learning. Verify the safety devices before normal operation. Deleting users is a separate function, U3. On a board with a different menu, A4 may restore a different range of settings; follow the instructions for that specific model variant.
Display-based diagnostics
| Code | Meaning / check |
|---|---|
| E1 | Calibration error. Check A3, the mechanics, direction, and limit switches. |
| E2 | Configuration error. Verify model A1, direction F54, and that travel learning is complete. |
| E3 | Encoder error. With the power off, check the +/E/− connector and wires; after repair, perform travel learning. |
| E4 | Safety test error. Check TX on TS, power supply, NC, and F5. |
| E7 | Operating time exceeded. Check resistance, stops, and that the movement completes. |
| E9 | Obstacle while closing. Remove the actual obstruction; check the rack and sensitivity. |
| E10 | Obstacle while opening. Check the travel path and that the force settings are correct. |
| E11 | Too many consecutive obstructions. Repair the mechanics or resolve the cause of the safety device activation. |
| E13 | Both limit contacts are open. Check FA/FC/F and the switching stops. |
| E14 | Serial communication error. Check RSE, CAT 5, and configuration. |
| E15 | Incompatible transmitter. Check AF, frequency, and U4. |
| E17 | Wireless system communication fault. Check RIO, devices, and interference. |
| E18 | Wireless system is not configured. Verify RIO and the relevant F65–F68 settings. |
If the gate does not move, check the power supply, drive release, STOP input and active safety inputs, a button that is stuck on, and the transmitter battery. If it opens but does not close, check the photocells and their NC contact. Do not bypass a safety device fault with a permanent jumper.
ZN7 fuses for 230 V
| Circuit | Fast-blow fuse |
|---|---|
| Mains LINE | 1.6 A-F |
| Accessories | 2 A-F |
Check fuses with the mains and batteries disconnected. Replace only with a fuse of the same rating and type; first eliminate the cause of the short circuit or overload.
Maintenance and servicing
Regularly check that the travel path and rack are clean, the gate moves easily by hand, the drive is securely fastened, the switching stops and cables are in good condition, the manual release works, and all safety devices function correctly. Disconnect the mains and battery backup before cleaning or carrying out any work. If there is damage, unusual noise, or vibration, stop operation and resolve the cause.
Set torque A6 and sensitivity F34/F35 according to the actual mechanics; do not mask resistance or a fault by increasing the torque. After adjustment or servicing, verify the full movement, forces, and safety devices. Record H1, the number of manoeuvres in A5, and any repairs. Give the user the instructions for the complete system and demonstrate the manual release. Take electronic components and batteries to a designated collection point for disposal.
Technical specifications of the CAME BXV08AGS
| Parameter | Value |
|---|---|
| Maximum gate leaf weight | 800 kg |
| Maximum gate leaf length | 20 m |
| Mains power supply to the drive | 230 V AC, 50/60 Hz |
| Motor power supply | 24 V DC |
| Power | 400 W |
| Thrust | 800 N |
| Maximum travel speed | 11 m/min |
| Maximum current – according to the manufacturer's technical data sheet | 16 A |
| Protection rating | IP44 |
| Operating temperature | −20 to +55 °C |
| Operation | Intensive use; this is not a fixed number of cycles per hour. |
| Operating time | 180 s |
| Standby power consumption | 5.5 W |
| Protection class | I |
| Rack / limit switches | Module 4 / mechanical |
| Cover colour | Grey RAL 7024 |
| Control unit in this manual | ZN7, display and ESC/arrows/ENTER |
| Setting A1 | 3 – 800 kg |
| Body dimensions (width × depth × height) | 290 × 212 × 363 mm |
| Anchor plate | 300 × 170 mm; spacing as shown in the drawing |