Drive kit for sliding gates up to 800 kg CAME BX708, 801MS-0030 (D)
| Product availability: | within 3 days | We usually dispatch goods within 3 days. |
|---|
within 3 days
€535.85 including VAT
| Weight |
|---|
| 16 kg |
Description of Drive kit for sliding gates up to 800 kg CAME BX708, 801MS-0030 (D)
CAME BX708AGS drive is designed for sliding gates with a weight up to 800 kg and a leaf length up to 14 m. It has an electromechanical stop switch. The drive is non-reversible. Detailed technical specifications ». Download the manual ».
CAME BX708AGS and ZBX7N control unit
The kit includes a gate operator for sliding gates weighing up to 800 kg with mechanical limit switches. The motor and power supply are 230 V AC; accessories are powered from a separate 24 V AC. The built-in encoder enables travel learning, obstacle detection and adjustable slow-down.
Before configuring, check the exact operator model, the ZBX7N marking on the board and the firmware version in H1. The list below is for an older control unit version with F8 options 0 = partial opening / 1 = opening. Matching F8 alone does not confirm that the entire version is the same. Even boards with the same name and F8 options may behave differently in terms of memory or technical specifications. Before making changes, compare the settings and procedure with the manual supplied with the specific board. If F8 has options 1/2, do not use the numbers and factory settings listed below. Do not confuse operators with a 230 V mains-powered motor with 24 V models.
Disconnect the power before handling terminals or plug-in cards. The operator must not be used as a substitute for missing mechanical stops or to overcome a faulty gate mechanism.
What’s included in the kit
BX708AGS operator with built-in ZBX7N control board, limit-stop plates for switching, radio frequency card AF43S, remote control TOP44RBN, a pair of photocells DIR10 and a warning light KLED230. The rack is selected according to the gate; it is not included in this kit.
CAME BX708 kit
| Feature | CAME BX708AGS |
|---|---|
| Kit | ![]() BX708 – up to 800 kg |
| Gate leaf weight | max. 800 kg |
| Gate leaf length | max. 14 m |
| Motor and control board | 230 V AC / ZBX7N |
| Limit switches | mechanical |
| Included equipment | AF43S, TOP44RBN, DIR10, KLED230 |
The higher weight limit of the BX708 does not increase the maximum gate leaf length. Choose based on the actual weight and length, resistance during movement and number of cycles; weight alone is not enough.
Accessories – what they are, why they’re needed and type
| What | Why | Type |
|---|---|---|
| Photocells | Protect the passage area while the gate is closing. |
|
| Remote control | Command for the full or partial travel distance. |
|
| Radio frequency card | Receives the remote control signal. |
|
| Warning light | Alerts people that the gate is moving. |
|
| Rack | Transfers motion to the gate leaf. |
|
| Push button / key switch | Local control or partial opening. |
|
| Safety edge | Protection against crushing at hazardous points. |
|
| Serial interface | Linking two operators or CRP communication. |
|
Choosing an operator and assessing the load
The maximum gate leaf weight is 800 kg, maximum length 14 m. When disengaged, the gate must move smoothly along its entire travel and have mechanical stops in both directions. If the gate jolts, sticks or encounters increased resistance, repair the track and mechanism first.
17 cycles per hour and 6 consecutive cycles apply to a reference gate leaf length of 4 m, a temperature of 20 °C and a correctly installed gate with no additional friction. These values do not apply to every gate length up to 14 m. For longer gate leaves and higher temperatures, the permissible number of cycles decreases, as shown in the original graphs.
Do not extrapolate the graphs beyond the last point shown. The number of cycles per hour is an operating limit, not a service-life guarantee.
Drive installation and wiring
- Check the stability of the gate leaf, rollers, track or guide, ease of movement, and secure mechanical stops. Secure hazardous areas at the rack and pinion.
- Choose a solid base protected from impacts and direct spray. Install conduits; Ø 40 mm is recommended for the drive and Ø 25 mm for accessories.
- The foundation formwork should be larger than the anchor plate and extend 50 mm above ground level. Add steel reinforcement. Secure the M12 bolts to the plate and route the conduits through its openings.
- For an existing rack, follow the original dimension detail of 84 / 105 mm. Level the plate and set it in concrete; allow at least 24 hours to cure.
- Leave approximately 600 mm of cable protruding. Remove the covers, place the drive on the plate, and use the adjustable feet to raise it by 5–10 mm before initially levelling it, leaving room for adjustment.
Recommended minimum cross-sections
| Cable run | Less than 20 m | More than 20 m and less than 30 m |
|---|---|---|
| 230 V AC supply, L/N/PE | 3G × 1.5 mm² | 3G × 2.5 mm² |
| Flashing light | 2 × 0.5 mm² | 2 × 0.5 mm² |
| Control contact | 2 × 0.5 mm² | 2 × 0.5 mm² |
| Photocell TX | 2 × 0.5 mm² | 2 × 0.5 mm² |
| Photocell RX | 4 × 0.5 mm² | 4 × 0.5 mm² |
Use H05RN-F for external mains wiring and H05VV-F for internal wiring; for low-voltage wiring up to 48 V, use FROR 20-22 II as appropriate. Antenna: RG58, recommended maximum length 5 m. Serial connection: UTP CAT5, maximum 1,000 m. For other distances, multiple loads or test wiring, provide the required conductors and cross-section according to the actual load and wiring configuration.
Route cables through separate cable glands; they must not touch the motor or transformer. The mains supply must have a suitable double-pole disconnect and a PE protective conductor.
Rack, clearance and end positions
- Disengage the drive. Attach the module 4 rack to the gate along its entire travel path. When joining sections, align the teeth using a spare piece of rack beneath the joint.
- Manually move the gate through its entire travel path. Adjust the height using the feet and the lateral position using the anchoring holes; leave a clearance between the rack and pinion of 1–2 mm. The weight of the gate leaf must not rest on the drive.
- Once level, firmly tighten the drive mounting.
- Open the gate manually. Slide the opening limit switch cam on the rack until it activates the microswitch spring, then secure it.
- Set the closing limit switch cam in the same way. According to the dimensional detail, leave approximately 20 mm. Check both directions and re-engage the drive.
Manual release during a power failure
- Disconnect the power supply and secure the gate leaf against unintended movement.
- Open the lock cover, insert the key and unlock the release flap.
- Swing open the flap and turn the release control in the open space behind it, following the arrow in the illustration. You can now move the gate manually.
- To re-engage the drive, turn the control back as shown in the locking illustration, close the flap, lock it with the key and close the lock cover.
- Check that the drive is engaged before restoring power. An open flap may trigger E8.
ZBX7N board orientation and terminals
In the illustration, the board is oriented with the terminal blocks at the top and the buttons ESC / < / > / ENTER at the bottom right. The display is at the bottom; PWR indicates that power is present. The circled numbers identify board components, not electrical terminal numbers.
| Position in the illustration | Board component |
|---|---|
| 1 / 2 / 3 | Mains supply / motor / transformer. |
| 4 / 6 / 22 | Board fuse / accessory fuse / mains fuse. |
| 5 | Control and safety inputs. |
| 7 | RGP1: + / STB / −, energy-saving module; not a battery input. |
| 8 / 10 / 11 | Encoder / mechanical limit switches / antenna. |
| 9 / 13 / 15 | Keypad / transponder terminals; R700 or R800 decoder socket. |
| 12 | AF radio card. |
| 14 / 17 | Serial terminals A/B/GND / RSE socket. |
| 16 | RIO-CONN socket for RIOCN8WS. |
| 18 / 19 / 20 / 21 | Programming buttons / Memory Roll / display / PWR LED. |
Power supply, motor and encoder
| Terminals | Connection and limit |
|---|---|
| L / N / PE | L = live, N = neutral; 230 V AC, 50/60 Hz. Connect the PE protective conductor to the marked earth point. This is not a +/− connection. |
| U / V / W | Factory motor wiring and capacitor; 230 V AC motor. There is no DC polarity. Use F54 to select the direction; do not swap the wiring by guesswork. |
| + / E / D | Encoder – factory wiring: + = red wire, E = black wire, D = shield, according to the original diagram. When reconnecting, follow the labels and original wiring; do not assign a different function to E or D based on wire color. These terminals are not for powering photocells; do not connect an external power supply here. |
| FC / FA / F | FC = closing limit switch; FA = opening limit switch; F = common wire. Do not confuse the factory wiring with the accessory power supply. |
| 10 / 11 | 24 V AC, max. 20 W for accessories. With AC voltage, there is no plus or minus. |
| TS | Test terminal for photocells; used with F5 and a specific test wiring diagram. It is not a substitute for a permanent power output. |
Buttons, STOP and safety inputs
| Input | Contact / use |
|---|---|
| 1–2 | STOP with voltage-free contact NC, enable F1. Opening the contact stops the gate and disables automatic closing; operation resumes with a new command. |
| 2–7 | Voltage-free contact NO; command according to F7. With F6 = ON, this is a hold-to-close command. |
| 2–3P | Voltage-free contact NO; partial or full opening according to F8. With F6 = ON, this is a hold-to-open command. |
| 2–CX / 2–CY | Safety contact NC, response according to F2/F3. The contact is non-polarized; do not apply an external voltage to it. |
| A / B – keypad | Code selector with R800 decoder; set F14 = 1. |
| S1 / GND | Transponder or reader with R700; set F14 = 0. The original diagram shows the red wire connected to S1 and the black wire to GND. |
| Antenna | RG58: connect the center conductor to the antenna signal input and the shield to the terminal marked with the shield symbol. |
NO means open at rest, NC means closed at rest, and the common contact terminal is COM/C. For a standard command, do not connect 230 V mains to inputs 2–7 or 2–3P. Disable an unused STOP input via F1; disable unused CX/CY inputs via F2/F3. Do not disable connected safety devices as a way of troubleshooting a fault.
Flashing light and status indication
| Output | Voltage / power / mode |
|---|---|
| W–E1 | KLED230: 230 V AC, output limit 25 W, F18 = OFF. For cycle lighting 230 V AC, max. 60 W, F18 = 1 and F19 enabled. AC, no +/−; do not connect a 24 V flashing light here. |
| 11–FA | Open-gate indication: 24 V AC, max. 3 W, no +/−. |
| 11–FC | Closed-gate indication: 24 V AC, max. 3 W, no +/−. |
CAME DIR10 photocells
DIR10 are a synchronized transmitter (TX) and receiver (RX) with a range of 10 m. For this wiring, set the photocells to 24 V; the supply is 24 V AC. The pair draws 60 mA at 24 V AC. In the original diagram, RX terminals 10 and TX TX are marked +, and terminals 2 are marked −; when powered from the control board, the supply is AC with no DC polarity. Follow the specific TX synchronization wiring, not just the pair of power wires.
| DIR10 terminal | Standard wiring | Wiring with test |
|---|---|---|
| RX 10 (marked +) | ZBX7N 10 | ZBX7N 10 |
| RX 2 (marked −) | ZBX7N 2 | ZBX7N 11 |
| RX TX ↔ TX TX (marked +) | Connect TX between the RX and transmitter | Same connection |
| TX 2 (marked −) | ZBX7N 2 | ZBX7N TS |
| RX C – common contact | ZBX7N 2 | ZBX7N 11 |
| RX NC – safety contact | ZBX7N CX, or CY | ZBX7N CX, or CY |
| Functions | F2 = C1 (for CX), F5 = OFF | F2 = C1 (for CX), F5 = 1 |
| For the CY input | F3 = selected response | F3 = selected response; F5 = 2, or 4 when testing both CX and CY |
With C1, opening the contact during closing triggers opening. C2 triggers closing when activated during opening; C3 stops movement, followed by automatic closing; available only when F19 is active. C4 stops movement and resumes operation once the obstacle is removed. Select the response according to the area being protected. After wiring, check operation by interrupting the beam during the relevant movement.
A test is more than just a menu option. First connect the terminals according to the test wiring diagram, then enable F5. If the test fails, the control board will not execute the command and will display E4. DELTA has different terminals; do not use this DIR10 terminal assignment for it.
Safety edges
Connect the DFWN edge with the NC volt-free contact between 2 and CX/CY, and select C7 or C8. For the DFI interface, use the separate power supply and contacts shown below; the edge with an NC contact is not powered this way. The r7/r8 options are intended for the corresponding 8.2 kΩ resistive edge, not for an arbitrary contact. The specific type, position and resulting force must be verified by a safety test.
| Original DFI terminal | ZBX7N / safety edge |
|---|---|
| 24V / 0V | DFI 24V → ZBX7N 10, DFI 0V → ZBX7N 11. The power supply in this diagram is 24 V AC, with no DC polarity +/−; terminal 12V is left unused. The shared output limit for accessories on terminals 10–11 is 20 W. |
| Pair of terminals marked with a contact symbol | On the original diagram, immediately to the right of 0V: left → ZBX7N 2, right → CX or CY. The volt-free safety contact is non-polarized; set its response using F2/F3. |
| C / NO / NC | Connect the corresponding DFI terminals to the C / NO / NC terminals of the DFWN edge as shown. Do not confuse these with the separate pair of output-contact terminals for the control board. |
First start-up
- Check the mechanical stops, limit switches, that the drive is properly locked, cable protection and safety wiring.
- Switch on the power; check the PWR LED and that the display works. In A1, check 2 = BX708AGS.
- Set F54 according to the actual travel direction, and F1 according to the connected STOP button. Configure CX/CY and, if applicable, the F5 test. Leave F11 = ON for learning.
- Run A3 – travel learning.
- Configure only the operating functions you need, add the transmitters, and test the full travel, partial opening, STOP, photocells, safety edges and warning light.
The first normal movement after switching on the power is opening. At this stage, wait for the gate to open fully; closing is not available. A3 calibration has its own sequence, shown below. If there is unusual noise, vibration or incorrect movement direction, press ESC/STOP immediately and eliminate the cause.
A3 – automatic travel learning
Prerequisites: F11 = ON, correct A1 and F54 settings, limit switches set, both fixed mechanical stops in place, and the gate leaf approximately halfway along its travel. After moving it manually, lock the drive again. Keep the entire travel path clear.
Safety devices are disabled during calibration. Supervise the entire movement directly and prevent anyone from entering the gate area.
- Press and hold ENTER for at least 1 second, select A3 using the arrow keys, then confirm with ENTER.
- Select ON and confirm with ENTER.
- The gate first closes to the end position; the display shows CL1.
- Then it opens to the end position; the display shows OP1. Do not enter the travel path.
- When complete, check a full cycle, stopping, and the selected response of each safety device. For E1 or E2, address the cause using diagnostics and repeat calibration only after the problem has been resolved.
Programming using the display
Make settings with the drive stopped. Press and hold ENTER for at least 1 second, use the </> arrow keys to select a function, and press ENTER to open its value. Change the value using the arrow keys, then press ENTER to confirm and save. ESC cancels an unconfirmed change and exits the menu; the menu also closes after 10 seconds of inactivity. Do not assume an unconfirmed change has been saved.
Outside the menu, use the arrow keys to move the gate during testing and ESC to stop it. Check programming values and confirmations on the display. The PWR LED indicates that power is present.
F functions – full settings
Factory values for the specified ZBX7N version are shown in bold. Function availability depends on the connected card, whether the encoder is enabled, and related functions. Record the original settings before making changes. Do not set F34/F35 sensitivity or start-up torque based on the maximum gate weight; after adjustment, you must check operating forces and safety protection.
Users and U / A / H system
Storing remote controls
ZBX7N with radio card AF43S 433.92 MHz supports up to 250 users. TOP44RBN uses Rolling Code at 433.92 MHz. The relevant code type must be enabled in menu U4; do not assume that any remote control on the same frequency is compatible.
Insert or remove the AF card only when the power is off. With U4 = 1, all supported codes are enabled; U4 = 2 limits reception to Rolling Code. Before confirming the U4 selection, be aware that the radio memory will be erased: in this older version, selecting a code type automatically deletes stored remote controls. First record the users and prepare to store them again; an F8 match alone does not verify how U4 behaves.
- Select U1 in the menu and press ENTER.
- Select the command: 1 = open/close; 2 = open–STOP–close–STOP; 3 = open only; 4 = partial opening.
- Confirm with ENTER. The available user number (1–250) will flash on the display for a few seconds.
- While it is flashing, transmit the code using the required button on the remote control. Record the stored position; after exiting the menu, test the command.
- Repeat U1 to add another function or user. If error E15 appears, check the card, frequency and code type.
Deleting one or all users
One user: U2 → ENTER → use the arrows to select the stored number → ENTER. Text CLr confirms deletion. All users: U3 → ENTER → ON → ENTER. U3 is not the A4 parameter reset or the A3 calibration.
Resetting parameters and transferring memory
A4 – Factory parameters
Before resetting, record A1, F54, the safety input settings, automatic closing and access details. Select A4, press ENTER, choose ON and press ENTER again. Then check all required parameters, calibration status and safety functions. Do not assume that A4 deletes all radio users; use U3 to delete them.
F50 / F51 – Memory Roll
- Disconnect the power and insert the Memory Roll into the marked socket.
- After switching on, select F50 = ON and press ENTER; users and configuration will be saved.
- Disconnect the power again before removing the card and inserting it into another compatible board.
- On the target board, select F51 = ON and press ENTER. Check that the transferred settings match the specific drive and installation.
- After the transfer, it is advisable to remove the card, always with the power off.
Two MASTER / SLAVE drives
Into of both boards With the power off, insert the RSE and connect A–A, B–B and GND–GND using UTP CAT5. Connect the commands and safety devices to the MASTER. On the MASTER, set F49 = 1, the correct F54, and F52 = ON, then confirm the transfer; next, run A3. Store users on the MASTER. The SLAVE programming buttons are disabled in coupled mode.
A standard open/close or open-only command operates both leaves; a partial-opening command opens only the MASTER. Coupling two drives does not increase the weight limit for a single leaf. For standalone CRP communication, use the relevant F49/F56/F63 settings, not MASTER/SLAVE mode.
RIO wireless safety devices
Connect the RIOCN8WS to the RIO-CONN with the power off. Configure the RIOED8WS safety edges and RIOPH8WS photocells using the relevant F65–F68 settings and according to their own wiring; the RIOLX8WS is for wireless signalling. Without configuration, the board may report E18; E17 indicates a connection fault or interference. Do not confuse the RIO-CONN with the AF socket for remote controls.
Diagnostics and troubleshooting
| Display | Meaning | Check / remedy |
|---|---|---|
| E1 | Calibration error. | Check the mechanical stops, limit stops, free movement, A1 and F54; then repeat A3. |
| E2 | Calibration / encoder setup. | First verify that A3 learningwas completed successfully, and check F11. E2 alone does not mean E3 – encoder fault. If the message remains after successful learning, check the factory encoder wiring and arrange servicing. |
| E3 | Encoder fault. | With the power off, check the connector and the +/E/D wires; have any damage repaired by a service technician. Do not disable the safety function as a substitute for repair. |
| E4 | Safety test error. | Compare the actual TS wiringand the photocells’ power supply and contact with F5 and F2/F3. |
| E7 | Insufficient operating time. | Check for resistance along the entire travel path, the end positions and calibration. Do not increase the force on a sticking gate. |
| E8 | Release door open. | Lock the mechanism and close the door; check that it is being detected. |
| E9 | Obstacle while closing. | Remove the obstacle; manually check the guide/rack, then F34/F35. |
| E10 | Obstacle while opening. | Remove the obstacle from the opening path, check the guide and limit switch; then adjust sensitivity. |
| E11 | Maximum number of detected obstacles reached. | Check for recurring resistance or an obstacle along the entire travel path, and check the encoder; after repair, perform a test. |
| E15 | Incompatible remote control. | Check the AF card, frequency and U4; do not try to resolve the error by resetting the entire board. |
| E17 | Wireless system error. | Check the RIO interface, devices and interference. The system may block movement. |
| E18 | Wireless system configuration missing. | Check the RIOCN8WS and configure the relevant F65–F68 settings and devices. |
When the gate won’t move or close
Does not move in either direction: Check the power supply, drive lock, door, STOP status and safety contacts, remote-control battery, and whether a command is stuck. Opens but does not close: Check the photocell beam, alignment, NC contact and CX/CY configuration; do not install a permanent jumper across a connected safety device.
ZBX7N fuses for 230 V
| Fuse | Rating / type |
|---|---|
| LINE – mains | 5 A-F, fast-acting |
| BOARD – control board | 630 mA-F, fast-acting |
| ACCESSORIES – accessories | 1 A-F, fast-acting |
Disconnect the power supply before checking fuses. Use the same rating and fast-acting type; a higher-rated fuse or repeated replacement without removing the short circuit is not a repair.
Maintenance and force adjustment
Regularly check that the travel path and rack are clean, that movement is free, the fixings and limit stops are secure, cables are undamaged, the release works, and every safety device functions correctly. Disconnect the power before cleaning or carrying out any work. Lubricate only mechanical parts that require it; the guide must not create additional friction.
The motor torque is adjusted using the transformer's black Faston connector, in positions 1 to 4: 1 is minimum, 4 is maximum. Move the connector only with the power off, following the original diagram. Encoder sensitivity is adjusted separately using F34/F35; higher torque or lower sensitivity does not replace correctly positioned safety edges and force testing.
The service record should include the date, number of A5 manoeuvres, H1 version, repairs carried out and the result of the safety-device test. When finished, refit the covers without pinching any cables.
BX708AGS technical specifications
The data applies to the specified drive and control unit version. Before installation, compare the power supply, motor designation and values with the motor’s rating plate.
| Parameter | Value |
|---|---|
| Maximum leaf weight | 800 kg |
| Maximum leaf length | 14 m |
| Mains power supply | 230 V AC, 50/60 Hz |
| Motor power supply | 230 V AC |
| Power | 530 W |
| Thrust | 800 N |
| Travel speed | 10 m/min |
| Ingress protection rating | IP44 |
| Operating temperature | −20 to +55 °C |
| Cycles per hour | 17 with a 4 m reference gate leaf / 20 °C |
| Consecutive cycles | 6 with a 4 m reference gate leaf / 20 °C |
| Capacitor | 20 µF |
| Standby power consumption | 2.4 W |
| Power consumption with Green Power module | 0.5 W; the module is not a standard battery backup |
| Motor thermal protection | 150 °C |
| Electrical protection class | I |
| Drive unit weight only | 15 kg |
| Pinion | module 4 |
| Limit switches | mechanical |
| Control unit | ZBX7N with display and encoder |
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]