Drive kit for sliding gates up to 600 kg CAME BXV06AGS, 801MS-0180 (D)


Product availability: within 3 days

We usually dispatch goods within 3 days.


Drive kit for sliding gates up to 600 kg CAME BXV06AGS, 801MS-0180 (D) Drive kit for sliding gates up to 600 kg CAME BXV06AGS, 801MS-0180 (D)
CAME-BXV06AGS-D
within 3 days
€451.47 excluding VAT
€555.31 including VAT

 pcs
Weight
12 kg

Description of Drive kit for sliding gates up to 600 kg CAME BXV06AGS, 801MS-0180 (D)

CAME BXV06AGS gate opener is designed for sliding gates weighing up to 600 kg and leaf length up to 18 m. It has an electromechanical stop switch. The gate opener is non-reversible. Detailed technical specifications ». Download the manual ».

CAME BXV06AGS with ZN7 control board is a sliding gate operator with a 24 V DC motor and mechanical limit switches. The mains supply is 230 V AC. It is designed for a gate leaf weighing up to 600 kg and 18 m long. Consider the gate’s weight, length and resistance together; a more powerful operator does not compensate for a gate that is difficult to move by hand.

Disconnect the mains supply and any batteries before carrying out any work. Photocells and the encoder do not replace mechanical stops, protection of hazardous areas, or force testing on the fully installed gate.

Before installation, check the operator label, the ZN7 board, the H1 version and its menu. The technical data and wiring diagrams below apply to the version described. The following settings apply to the version with F28 = 60–100%, F8 = 1/2 and U3 = 0/1. If the board offers different values or connectors, use the manual for that specific version; these three items alone do not identify the entire firmware.

Quick navigation
BXV06AGS kitAccessories
InstallationWiring
Manual releaseBoard layout
Terminals and power supplyPhotocells and testing
Initial start-upLearning the travel limits
ProgrammingRemote controls
Reset and memoryDiagnostics
MaintenanceTechnical specifications
Installation manual (PDF)

CAME BXV06AGS kit

Both kits include the operator, remote control, photocells, radio receiver and flashing light. Check the markings on the accessories actually supplied before wiring. Select additional components, especially the rack and local controls, to suit the specific gate.

SpecificationCAME BXV06AGS
KitCAME BXV06AGS kit
CAME BXV06AGS, 801MS-0180 (D)
Maximum gate leaf weight600 kg
Maximum gate leaf length18 m
Mains / motor230 V AC / 24 V DC
Power / force270 W / 600 N
Maximum speed12 m/min
Motor selection A12–600 kg
Controller covered in this manualZN7, display and menu

The 18 or 20 m figure indicates the maximum gate leaf length, not necessarily the clear opening width. A1 selection does not change the physical operator’s load capacity.

Accessories and wiring examples

The following examples are for specifically identified devices. For a different type, use its own terminals and parameters; the same function or frequency alone does not confirm compatibility.

ComponentVerified example / application
PhotocellsCAME DIR10, 12/24 V AC/DC, 10 m range; wiring and TS test.
Flashing lightCAME KLED24, 24 V AC/DC, 2 W; output 10–E.
Radio receiverCAME AF43S, plug-in AF card, 433.92 MHz; check the coding together with U4.
Remote controlCAME TOP-432EE, fixed code, 433.92 MHz; example for a compatible receiver.
RackToothed racks, module 4; clearance and fixing.
Local controlsSwitches, push buttons and readers; NO commands and NC safety contacts according to the terminal layout.

Operator installation

With the operator released, the gate must move easily along its entire travel, without sloping, damaged wheels or any risk of coming off the guide. Check that fixed mechanical stops are fitted in both the open and closed positions, that the base is stable, and that areas where the gate leaf could trap someone are protected. Water must not collect around the operator or be directed at it in a direct stream. If the sliding gate leaf has an integrated pedestrian gate, motorised operation must only be possible when it is securely closed.

Foundation and anchor plate

The installation example uses an excavation 400 × 240 mm and 800 mm deep. Adapt the foundation dimensions to the ground conditions and the specific gate. The formwork projects 50 mm above ground level; use reinforcement and M12 anchors. A Ø 40 mm conduit is recommended for the operator supply, Ø 25 mm for accessories and Ø 20 mm for any manual-release cable.

Example of the foundation and conduit routing for BXV
Example of the foundation and conduit routing for BXV
Formwork 50 mm above ground level and reinforcement for the concrete foundation
Formwork 50 mm above ground level and reinforcement for the concrete foundation

Set the anchor plate level, route the cables through its openings and leave the threaded sections of the anchors above the surface. Allow the concrete to cure for at least 24 hours. Position the plate relative to the rack as shown: the 95 mm horizontal offset and 106 mm height refer to the marked surfaces in the cross-section. Do not confuse these with the foundation dimensions.

Anchor plate, holes and M12 fixing
Anchor plate, holes and M12 fixing
Position of the anchor plate relative to the BXV rack
Position of the anchor plate relative to the BXV rack

Installing and setting the height

Remove the cover and fit the operator onto the plate. The cables must pass through the underside of the housing and through properly fitted cable glands. When adjusting, raise the operator using the threaded feet by 5–10 mm, to leave room for adjusting the meshing.

Fitting the BXV operator onto the plate
Fitting the BXV operator onto the plate
Cable gland and height adjustment for the BXV operator
Cable gland and height adjustment for the BXV operator

Rack and meshing clearance

Release the operator and fit the rack while moving the gate leaf by hand. When joining rack sections, use a spare rack section beneath the joint so the teeth align smoothly. After installation, adjust both the vertical and horizontal position of the operator.

Installing the BXV rack
Installing the BXV rack

Leave a 1–2 mm gap between the rack and the pinion. The gate must not rest on the drive. Move the gate manually along its entire travel, check the meshing and rack joints, and only then tighten the nuts and washers on the anchors.

1–2 mm gap and BXV meshing adjustment
1–2 mm gap and BXV meshing adjustment

Mechanical limit switches

Manually move the gate leaf to the open position. Attach the opening switch stop to the rack so that its ramp reliably actuates the spring-loaded microswitch. Set the closing stop in the same way. Secure the stops firmly; the gate’s fixed mechanical stop and the drive’s switch stop serve different purposes.

In the illustrated setup, leave approximately 20 mm before the fixed stop. Check the run-on distance at the actual speed and under load.

Mechanical switch stop at the open position
Mechanical switch stop at the open position
Mechanical switch stop at the closed position
Mechanical switch stop at the closed position

Wiring

ConnectionCable / requirement
230 V AC mains, L/N/PE3G × 1.5 mm² up to 20 m; 3G × 2.5 mm² for 20–30 m.
Control devicesNumber of conductors depends on the control device; 0.5 mm² cross-section for the short cable runs listed.
DIR10 photocellsTX: 2 × 0.5 mm²; RX: 4 × 0.5 mm². Ensure the TX link and NC contact are connected.
AntennaRG58, maximum 10 m; 5 m or less recommended.
RSE / CRPUTP CAT 5; separate serial connection, not motor power supply.

The number of conductors must support the entire selected wiring diagram. For longer runs, simultaneous loads, or other accessories, calculate the cross-section based on current and voltage drop. Protect cables from damage and contact with the motor or transformer; route the mains supply and low-voltage circuits with suitable separation.

Manual release in the event of a power failure

Disconnect the power supply and secure the gate leaf before moving it manually. Releasing a damaged or unbalanced gate may cause uncontrolled movement.

  1. Insert the key into the lock and turn it in the direction of the arrow shown in the illustration.
  2. Pull and open the release lever as shown in the illustration.
  3. Move the gate manually in a controlled manner, keeping people clear of its path.
  4. To secure it again, return the lever to its original position and lock the mechanism. Before operating the motor, check that the drive is engaged.
Manual release and re-engagement of the BXV
Manual release and re-engagement of the BXV

ZN7 control board overview

The ZN7 has a display and ESC, arrow, and ENTER buttons. Settings, timers, and users are managed through the menu. The AF, Memory Roll, R700/R800, RSE, and RIOCN8WS connectors serve different purposes; insert or remove the card only when both the mains supply and batteries are disconnected.

ZN7 control board display, terminals, and connectors
ZN7 control board display, terminals, and connectors

Figure numberComponent
1 / 2 / 3Motor / encoder / limit switches
4 / 5 / 6Commands and safety devices / antenna / AF
7 / 8 / 9 / 10Memory Roll / R700 or R800 / RSE / RIOCN8WS
11 / 12Display / programming buttons
13 / 14 / 15A–B–GND serial connection / A–B keypad / S1–GND transponder
16 / 17 / 18GSM module / RGP1 / accessories and lights
19 / 20 / 21 / 22Accessory fuse / board input / mains fuse / mains supply

ZN7 terminals and power supply

TerminalsUse / voltage / polarity
L / N / PE230 V AC mains, 50/60 Hz for BXV06AGS. PE is the protective conductor; AC has no +/− polarity.
10 / 11Accessories: typically 24 V AC, in battery operation 24 V DC, total load not exceeding 40 W. For DC 10 = positive (+), 11 = negative (−); no polarity for AC.
10 / EFlashing beacon or cycle light, 24 V AC/DC, max. 25 W. For DC, 10 is the positive common terminal and E is the switched output.
10 / 5Gate status indicator, 24 V AC/DC, max. 3 W. For DC, 10 is the positive common terminal and 5 is the switched output; not for continuous power supply.
24 / 0Internal board supply from the power section; do not connect as an accessory output or external battery input.
M / N24 V DC motor; retain the wiring for the correct assembly. Not a 230 V supply.
+ / E / −Encoder: +/− power supply and E signal; not a general-purpose accessory output.
F / FA, F / FCF common, FA open, FC closed; NC limit contacts, no polarity.
A / B / GND – RSESerial interface with the RSE card; do not confuse with the A/B keypad connection.

ZN7 accessory power output, 10 (+) and 11 (−) for DC
ZN7 accessory power output, 10 (+) and 11 (−) for DC

Commands and safety contacts

TerminalsContact / operation
1–2NC STOP; set F1 = ON if connected. Factory setting: F1 = OFF. No polarity.
2–7NO command; operation selected by F7. Voltage-free contact, no polarity.
2–3PNO partial or full opening, as selected by F8. Voltage-free contact, no polarity.
2–CX / 2–CYNC safety inputs; configure F2/F3. No polarity.
10 / TSTested photocell power supply branch as shown in the diagram; do not activate F5 without correct wiring.
A–B / R800Code keypad with R800 decoding card, F14 = 1.
S1–GND / R700Transponder or reader with R700, F14 = 0.
Antenna / AFRG58 and plug-in radio card with the correct frequency/coding.

STOP, commands, reader and keypad on ZN7
STOP, commands, reader and keypad on ZN7

Flashing light and status indicator

KLED24, 24 V AC/DC and 2 W, connect to 10–E; set F18 = 0. KLED24 does not have a separately marked +/− supply lead. With AC there is no DC polarity; with DC, 10 is the board’s positive common terminal. Do not connect a 230 V flashing light to this 24 V output.

Output 10–5 is for a small status indicator, max. 3 W, with setting F10. Cycle light mode F18 = 1 requires an automatic closing time; the light stays on from opening until fully closed, including during the waiting period.

Light, flashing light and status indicator on ZN7
Light, flashing light and status indicator on ZN7
Wiring the CAME KLED24 24 V flashing light
Wiring the CAME KLED24 24 V flashing light

Photocells and safety test

CAME DIR10 consists of a TX transmitter and an RX receiver with a range of 10 m. Set the receiver jumper to 24 V. The pair draws 60 mA at 24 V AC. RX power terminals are marked 10 (+), 2 (−); TX has terminals TX and 2; the manufacturer does not show a separate +/− marking for these in this diagram. With AC power, DC polarity does not apply. The TX terminal is part of the synchronisation circuit; connect RX TX to TX TX as shown in the diagram and do not replace this connection with a direct feed from board terminal 10.

CAME DIR10 photocell TX and RX terminals
CAME DIR10 photocell TX and RX terminals
DIR10 jumper for 12 or 24 V power supply
DIR10 jumper for 12 or 24 V power supply

Photocell terminalStandard wiringWiring with test
RX 10 (+)Board 10Board 10
RX 2 (−) and RX CBoard 2Board 2
RX TX ↔ TX TXConnect TX between the receiver and transmitterSame connection
TX 2Board 2Board TS
RX NCBoard CXBoard CX

C–NC is a volt-free safety contact. It has no positive or negative terminal. The power supply wiring and the contact wiring are two separate circuits. With DC, 10 is positive; in this specific diagram, the RX 2 negative terminal is connected to the board’s common terminal 2. Do not confuse terminal 2 with power supply terminal 11.

For a contact on CX, set F2 = C1. For a contact on CY, select the corresponding response using F3. C1 reopens during closing, C2 recloses during opening, C3 stops and then closes automatically and requires F19; C4 waits for the obstacle to be removed and then resumes movement.

Standard wiring of synchronised photocells on ZN7
Standard wiring of synchronised photocells on ZN7

Wiring the test via TS

For the test, TX 2 is moved to TS, while RX 2 and RX C remain on board terminal 2. The TX connection between the transmitter and receiver remains in place. First change the wiring with the power off, and only then enable the test.

Set F5 = 1 for CX, 2 for CY, or 4 for both CX and CY. If the test fails, E4 is displayed and the drive will not execute the command. This function is used with active safety inputs.

Wiring synchronised photocells with the TS test on ZN7
Wiring synchronised photocells with the TS test on ZN7

After wiring, test by interrupting the beam during the relevant movement and then clearing it. Do not bypass the safety input as a permanent fault fix.

Safety edges

Connect the NC contact edge between 2 and CX or CY, and select C7 – reopening during closing, or C8 – reclosing during opening. A volt-free contact has no polarity. Do not connect a resistive edge as a standard NC contact; it must have an interface suitable for the specific controller.

Initial startup of ZN7

  1. Check that the gate moves freely, the rack and fixed and switching stops are secure, the drive is engaged, the wiring is correct and hazardous areas are protected.
  2. Switch on the power and check the display. Set A1 = 2 for a motor up to 600 kg, F54 according to the direction and F1 according to the connected STOP.
  3. Set F2/F3 for the connected safety devices and, if applicable, test F5. Leave unused inputs disabled. For learning, F11 must be ON.
  4. Run A3 – travel learning.
  5. Set the operating parameters and users, then test a full cycle, partial opening, each safety device, the flashing light and behaviour after a power failure.

The first normal manoeuvre after switching on the power is opening; wait for it to finish. A3 calibration has its own sequence. If there is unusual noise, vibration or incorrect direction of travel, stop immediately using ESC/STOP and rectify the cause.

A3 – automatic travel learning

Prerequisites: correct A1 and F54 settings, STOP configured, encoder active, limit switches set correctly and fixed stops in place. Move the gate manually to approximately halfway and re-engage the drive. Keep the area clear.

During calibration, the safety devices are disabled, except for stopping with the ESC button. Supervise the entire movement and prevent anyone from entering the travel path.

  1. Press ENTER, use the arrow keys to select A3, then confirm with ENTER.
  2. Select ON and confirm with ENTER.
  3. The drive first closes the gate to the end position; the display shows CL1.
  4. It then opens the gate to the end position; the display shows OP1.
  5. When complete, check the full movement and safety devices. For E1/E2, first rectify the cause as described in diagnostics; do not repeat the learning process due to a mechanical fault.
ZN7 Calibration – closing CL1 and opening OP1
ZN7 Calibration – closing CL1 and opening OP1

Programming via the display

Program with the drive stopped. ENTER opens the menu and confirms the selection; arrows </> select an item or change a value. After making a change, press ENTER to confirm. ESC cancels an unconfirmed change, goes back, or exits the menu. During normal operation, ESC stops the drive; the arrows allow test movement.

ESC, arrow and ENTER buttons on ZN7
ESC, arrow and ENTER buttons on ZN7

Factory values for the menu shown are indicated in bold. Accessory functions appear only when the required card is installed or a related function is active. Write down the current settings before changing them. A lower F34/F35 sensitivity value means higher sensitivity; after changing the speed, torque, or sensitivity, check the forces and safety devices.

F functions

Function and descriptionValues / factory setting
F1 – Complete stop
NC input 1–2. STOP disables automatic closing; resume with a new command. If no STOP button is connected, leave set to OFF.
OFF
ON
F2 – CX input
Contact 2–CX; select according to the photocell or safety edge. C3 requires F19.
OFF – disabled
C1 – reopen during closing
C2 – reclose during opening
C3 – stop, then close automatically
C4 – wait for the obstacle to be removed, then resume
C7 – safety edge: reopen during closing
C8 – safety edge: reclose during opening
F3 – CY input
Contact 2–CY; second independent safety input. C3 requires F19.
OFF – disabled
C1 – reopen during closing
C2 – reclose during opening
C3 – stop, then close automatically
C4 – wait for the obstacle to be removed, then resume
C7 – safety edge: reopen during closing
C8 – safety edge: reclose during opening
F5 – Photocell test
The tested circuit must be wired via TS. Testing is always active for wireless devices.
0 – disabled
1 – CX
2 – CY
4 – CX and CY
F6 – Hold-to-run control
The drive stops when the button is released; all other controls are disabled. Use only with controls in view; test to verify the direction of each button.
0 – disabled
1 – active
F7 – 2–7 command
Assigns an action to the wired command.
0 – open – close – reverse direction
1 – open – STOP – close – STOP
2 – open only
3 – close only
F8 – 2–3P command
With the encoder enabled, partial opening is set by F36; with it disabled, by F71.
1 – partially open
2 – fully open
F9 – Obstacle with motor stopped
When the gate is open, closed, or fully stopped, movement is prevented if the safety device detects an obstacle.
OFF
ON
F10 – Gate status indication
Output 10–5, 24 V AC/DC, max. 3 W.
0 – on when the gate is open and while it is moving
1 – flashes every 0.5 s while opening and every 1 s while closing; open = on, closed = off
F11 – Encoder
Controls deceleration, obstacle detection, and sensitivity.
ON – enabled
OFF
F12 – Soft start
For the first few seconds after a command, the gate moves at a low speed.
OFF
ON
F14 – Sensor type
Access device with the corresponding decoding card.
0 – transponder / card reader with R700
1 – code keypad with R800
F18 – Light 10–E
Output 24 V AC/DC, max. 25 W. Cycle lighting requires automatic closing to be set.
0 – flashing light while moving
1 – cycle lighting from opening until fully closed, including during the waiting time
F19 – Automatic closing
Delay after fully opening. Not activated after a complete STOP, a power failure, or activation of the obstacle-detection safety device.
OFF – disabled
1 to 180 s
F20 – Closing after partial opening
Requires F19 to be active; the same restrictions apply for STOP, power failure, and an obstacle.
OFF
1 to 180 s
10 s – factory value
F21 – Pre-flashing
Flashing light lead time before movement.
OFF
1 to 10 s
F28 – Opening speed
Percentage of maximum opening speed; after changing it, check the full movement cycle and safety.
60 to 100%
100% – factory value
F30 – Deceleration speed
Deceleration during opening and closing; only when the encoder is active.
10 to 50%
50% – factory value
F34 – Travel sensitivity
Obstacle detection during normal movement. A lower value means higher sensitivity.
10 to 100%
10% – highest sensitivity
100% – lowest sensitivity
F35 – Deceleration sensitivity
Only with the encoder active; check forces after changing the setting.
10 to 100%
10% – highest sensitivity
100% – lowest sensitivity
F36 – Partial opening point
Percentage of the total travel; only with the encoder active.
10 to 80%
10% – factory setting
F37 – Opening slowdown point
Start of slowdown as a percentage of the total travel; encoder only.
10 to 60%
25% – factory setting
F38 – Closing slowdown point
Start of slowdown as a percentage of the total travel; encoder only.
10 to 60%
25% – factory setting
F49 – RSE serial interface
Requires a card in the RSE connector.
0 – disabled
1 – synchronized drives
3 – CRP communication
F50 – Save data
Users, times and configuration to Memory Roll; this function is shown only when memory is inserted.
0 – do not execute
1 – save
F51 – Load data
Load saved data from Memory Roll; this function is shown only when memory is inserted.
0 – do not execute
1 – load
F52 – MASTER → SLAVE transfer
Transfer parameters to the second drive; only with synchronized RSE.
OFF
ON – transfer
F54 – Opening direction
Select according to the actual installation.
0 – left
1 – right
F56 – CRP address
Unique board address when multiple drives are connected to CRP.
1 to 255
F63 – Serial communication speed
Set to match the connected system.
0 – 1,200 bps
1 – 2,400 bps
2 – 4,800 bps
3 – 9,600 bps
4 – 14,400 bps
5 – 19,200 bps
6 – 38,400 bps
7 – 57,600 bps
8 – 115,200 bps
F65 – RIO ED T1
First wireless safety edge; only with the appropriate RIO interface.
OFF
P0 – STOP, no automatic closing; resume with a new command
P7 – reopen while closing
P8 – reclose while opening
F66 – RIO ED T2
Second wireless safety edge; check channel T2 and this item on the display.
OFF
P0 – STOP, no automatic closing; resume with a new command
P7 – reopen while closing
P8 – reclose while opening
F67 – RIO PH T1
First wireless photocells; only with the RIO interface. P3 requires automatic closing.
OFF
P1 – reopen while closing
P2 – reclose while opening
P3 – partial stop with automatic operation
P4 – wait for the obstruction to be removed
F68 – RIO PH T2
Second wireless photocells; only with the RIO interface. P3 requires automatic closing.
OFF
P1 – reopen while closing
P2 – reclose while opening
P3 – partial stop with automatic operation
P4 – wait for the obstruction to be removed
F71 – Partial opening time
Used when encoder F11 is disabled; when the encoder is active, set F36.
5 to 40 s

Users and system U / A / H

Function and descriptionOptions / confirmation
U1 – Add a new user
Pair a remote control/access device; up to 250 users.
1 – step-by-step
2 – sequential
3 – open only
4 – partial opening
U2 – Delete one user
Select the memory slot number with the arrow keys or activate the relevant remote control; ENTER confirms, and CLr indicates deletion.
OFF
ON – select and delete a user
U3 – Delete all users
Deletes all saved users.
0 – do not execute
1 – delete
U4 – Radio coding
Selecting 2 or 3 removes stored transmitters with a different coding. Record the users and check the control unit version before confirming.
1 – all supported coding types
2 – Rolling Code
3 – TWIN / TW key block
A1 – Motor type
For BXV06AGS, the value must be 2. Another option does not change the physical motor's load capacity.
1 – 400 kg
2 – 600 kg
3 – 800 kg
4 – 1,000 kg
A3 – Travel learning
Starts automatic calibration.
OFF
ON – start
A4 – Reset parameters
Restores factory settings and deletes the learned travel limits. Reconfigure and check safety before operation.
OFF
ON – execute
A5 – Operation counter
Displays the number of individual movements; this is not the number of complete opening/closing cycles.
001 = 100 operations
010 = 1,000
100 = 10,000
999 = 99,900
CSI = service intervention
A6 – Motor torque
Set according to the mechanism; after changing it, measure the forces and verify the safety devices.
1 – minimum to 5 – maximum
H1 – Firmware version
Displays the FW and GUI versions; record them for servicing and to verify the configuration.
Display version

Pairing and deleting remote controls

The ZN7 memory can store 250 users. The receiver must be installed in the AF and match the transmitter's frequency and coding. An example of a 433.92 MHz fixed code is TOP-432EE with AF43S. U4 can restrict the range of codes accepted; matching frequency alone is not sufficient.

  1. In U1, select the function: 1 step-by-step, 2 sequential, 3 open only, or 4 partial opening.
  2. Press ENTER to confirm, then transmit the code by pressing the selected button on the remote control.
  3. Repeat the procedure for the next user. Record the storage numbers and assigned commands, then test the actual operation.

To delete one user, use U2: select ON, choose a number using the arrows or activate the relevant stored transmitter, then press ENTER to confirm. CLr on the display confirms deletion. U3 = 1 deletes all users.

U4 = 2 (Rolling Code) or 3 (TWIN) deletes previously stored transmitters using different coding. Before making changes, check the system, H1 version, and remote control records; do not use this change as a trial-and-error fix for receiver faults.

Backup using Memory Roll

  1. Disconnect the mains power and any batteries, then insert the Memory Roll into its connector.
  2. Switch on the power; use F50 = 1 to save the data and F51 = 1 to load it. Loading replaces the board's data with the saved data.
  3. When finished, disconnect the power again and remove the memory card.
  4. After loading, check the model, direction, safety devices, and all commands. This ZN7 has a Memory Roll connector; do not use a USB port that is not present.

Pairing two drives

An RSE card is used on each board, with a CAT 5 connection via A–B–GND as shown in the diagram. Connect the control and safety devices to the MASTER board. On that board, set F49 = 1, the direction using F54, and parameter transmission using F52. Store users on the MASTER; partial opening and the step-by-step command operate as shown for the combined system.

RSE and MASTER–SLAVE connection for two BXV drives
RSE and MASTER–SLAVE connection for two BXV drives

RIO wireless safety system

RIOCN8WS uses a dedicated RIO connector. F65/F66 set the two wireless safety edges, and F67/F68 set the two photocell channels. Check the actual item and channel shown on the display. The wireless safety test remains active; resolve connection loss E17 or missing configuration E18 before resuming operation.

A4 – parameter reset

Before resetting, record the H1 version, settings, and users; if you have a Memory Roll, save the data. In A4, select ON and press ENTER to confirm. For the configuration described here, the factory settings are restored and the travel path learning is cleared.

After resetting, set A1, F54, F1, the safety inputs, and A3 learning again. Check the safety devices before normal operation. Deleting users is a separate function, U3. On a board with a different menu, A4 may reset a different range of settings; refer to the specific configuration of that board.

Display diagnostics

CodeMeaning / check
E1Calibration error. Check A3, the mechanism, direction, and limit switches.
E2Setting error. Check model A1, direction F54, and completion of the learning procedure.
E3Encoder error. With the power off, check the +/E/− connector and wires; repeat the learning procedure after repair.
E4Safety test error. Check TX on TS, power supply, NC, and F5.
E7Operating time exceeded. Check resistance, stops, and whether movement completes.
E9Obstacle while closing. Remove the actual obstacle; check the rack and sensitivity.
E10Obstacle while opening. Check the travel path and correct force settings.
E11Too many consecutive obstacles. Repair the mechanism or address the cause of the safety device activation.
E13Both limit contacts are open. Check FA/FC/F and switching stops.
E14Serial communication error. Check RSE, CAT 5, and configuration.
E15Incompatible transmitter. Check AF, frequency, and U4.
E17Wireless system communication fault. Check RIO, devices, and interference.
E18Wireless system is not configured. Check RIO and the relevant F65–F68 settings.

If the gate does not move, check the power supply, drive release, STOP, active safety inputs, a button that is stuck on, and the transmitter battery. If it opens but does not close, check the photocells and their NC contact. Do not bypass a faulty safety device with a permanent jumper.

ZN7 fuses for 230 V

CircuitFast-acting fuse
Mains LINE1.6 A-F
Accessories2 A-F

Check fuses with the mains and batteries disconnected. Replace only with a fuse of the same rating and type; first eliminate the cause of the short circuit or overload.

Maintenance and servicing

Regularly check that the travel path and rack are clean, the gate moves easily by hand, the drive is secure, the switching stops and cables are in good condition, the release works, and all safety devices function properly. Disconnect the mains and battery backup before cleaning or carrying out any work. If there is damage, unusual noise, or vibration, stop operation and address the cause.

Set A6 torque and F34/F35 sensitivity according to the actual mechanism; do not mask resistance or a fault by increasing the torque. After adjustment or servicing, check the full movement, forces, and safety devices. Record H1, the number of operations shown by A5, and any repairs. Give the user the manuals for the complete system and demonstrate the manual release. Dispose of electronic equipment and batteries at a designated collection point.

CAME BXV06AGS technical specifications

ParameterValue
Maximum leaf weight600 kg
Maximum gate leaf length18 m
Drive power supply – mains230 V AC, 50/60 Hz
Motor power supply24 V DC
Power270 W
Thrust600 N
Maximum travel speed12 m/min
Maximum current – value from the manufacturer's technical data table11 A
Protection ratingIP44
Operating temperature−20 to +55 °C
OperationIntensive use; this is not a fixed number of cycles per hour.
Operating time180 s
Standby power consumption5.5 W
Protection classI
Rack / limit switchesModule 4 / mechanical
Cover colorGrey RAL 7024
Control unit in this manualZN7, display and ESC/arrows/ENTER
Setting A12–600 kg
Body dimensions (width × depth × height)290 × 212 × 363 mm
Anchor plate300 × 170 mm; spacing as shown in the drawing

Dimensioned drawing of the CAME BXV06AGS drive
Dimensioned drawing of the CAME BXV06AGS drive

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about Drive kit for sliding gates up to 600 kg CAME BXV06AGS, 801MS-0180 (D)

Product: Drive kit for sliding gates up to 600 kg CAME BXV06AGS, 801MS-0180 (D)
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.