Drive kit for sliding gates up to 400 kg CAME BXV04AGS, 801MS-0150 (D)
| Product availability: | within 3 days | We usually dispatch goods within 3 days. |
|---|
within 3 days
€520.68 including VAT
| Weight |
|---|
| 12 kg |
Description of Drive kit for sliding gates up to 400 kg CAME BXV04AGS, 801MS-0150 (D)
CAME BXV04AGS drive is designed for sliding gates weighing up to 400 kg and a passage width of up to 14 m. It has an electromechanical stop switch. The drive is non-reversible. Detailed technical specifications ». Download the manual ».
BXV04AGS with ZN7 control board is a sliding gate operator with a 24 V DC motor and mechanical limit switches. The mains supply is 230 V AC. Consider the gate’s weight, length and resistance together; the operator is not suitable for a gate that moves with difficulty or is damaged.
Disconnect the mains supply and any batteries before carrying out work. The encoder and photocells do not replace fixed stops, protection of hazardous areas, or force testing on the completed gate.
Check the ZN7 board and its menu before programming. The values shown correspond to menu settings F28 = 60–100 %, F8 = 1/2 and U3 = 0/1. If your board offers different values, use the settings for its specific version; view the version via H1.
CAME BXV04AGS kit
The kit includes a 24 V motor, remote control, photocells, radio receiver and warning light. Select additional components, especially the rack and supplementary controls, to suit the specific gate. Check the control unit designation and supplied components before connecting them.
| Feature | CAME BXV04AGS |
|---|---|
| Kit | ![]() BXV04AGS / 801MS-0150 (D) |
| Max. gate leaf | 400 kg / 14 m |
| Motor / power | 24 V DC / 170 W |
| Control unit in this manual | ZN7: display and menu |
| Operation | Intensive operation |
| Radio memory | 250 users |
Compatible accessories
| What | Why | Type |
|---|---|---|
| Photocells | Monitor the passage; select the response of the safety input. |
|
| Warning light | Signals gate movement. |
|
| Receiver | Radio control with matching coding. |
|
| Remote control | An additional transmitter for a compatible fixed-code system. |
|
| Rack | Transfers movement to the gate leaf. |
|
| Push button / key switch | Local command or STOP. |
|
Operator installation
With the operator released, the gate must move easily along its entire travel path, without sloping, damaged wheels or risk of coming off the guide. Check that firm mechanical stops are in place in both the open and closed positions, that the base is stable, and that areas where the gate leaf could trap someone are protected. Water must not collect in the operator area or be directed onto it in a jet.
Foundation and anchor plate
The installation example uses an excavation 400 × 240 mm and 800 mm deep. Adapt the foundation dimensions to the ground conditions and the specific gate. The formwork extends 50 mm above ground level; use reinforcement and M12 anchors. A Ø 40 mm conduit is recommended for the operator supply cable, Ø 25 mm for accessories and Ø 20 mm for any release cable.
Level the anchor plate, route the cables through its openings and leave the threaded parts of the anchors protruding above the surface. Allow the concrete to cure for at least 24 hours. Position the plate relative to the rack according to the dimensional drawing; the pinion height differs between these two operators.
Installation and height adjustment
Remove the cover and mount the operator on the plate. The cables must pass through the underside of the housing and correctly fitted cable glands. While adjusting, raise the operator using the threaded feet by 5–10 mm, leaving room to adjust the mesh.
Rack and gear mesh clearance
Release the operator and attach the rack while moving the gate leaf by hand. When joining the sections, use a spare rack section under the joint so the teeth align smoothly. After installation, adjust the operator’s vertical and horizontal position.
Leave 1–2 mm of clearance between the rack and pinion. The weight of the gate must not rest on the operator. Move the gate through its full travel by hand and check the mesh and rack joints; only then tighten the nuts and washers on the anchors.
Mechanical limit switches
Move the gate leaf to the open position by hand. Attach the opening limit-switch tab to the rack so that its ramp reliably actuates the spring-loaded microswitch. Set the closing limit-switch tab in the same way. Secure the limit-switch tabs firmly; the gate’s fixed mechanical stop and the operator’s limit-switch tab serve different purposes.
In the assembly shown, leave approximately 20 mm before the fixed stop. Check the stopping distance at the actual speed and under load.
Wiring
| Connection | Cable / condition |
|---|---|
| 230 V AC mains, L/N/PE | 3G × 1.5 mm² up to 20 m; 3G × 2.5 mm² for 20–30 m. |
| Controls | Number of conductors depends on the control; 0.5 mm² cross-section for the short runs specified. |
| DIR10 photocells | TX: 2 × 0.5 mm²; RX: 4 × 0.5 mm². Ensure the TX connection and NC contact are wired correctly. |
| Antenna | RG58, max. 10 m; 5 m or less recommended. |
| RSE / CRP | UTP CAT 5; separate serial connection, not for motor power. |
The number of conductors must support the entire selected wiring diagram. For longer runs, simultaneous loads or other accessories, calculate the cross-section based on current and voltage drop. Protect cables from damage and contact with the motor or transformer; route the mains supply and low-voltage circuits suitably separated.
Manual release in the event of a power failure
Disconnect the power and secure the gate leaf before moving it manually. Releasing a damaged or unbalanced gate can cause uncontrolled movement.
- Insert the key into the lock and turn it in the direction of the arrow shown in the illustration.
- Pull and open the release lever as shown in the illustration.
- Move the gate manually in a controlled manner, keeping people clear of its path.
- To re-engage the mechanism, return the lever to its original position and lock it. Before operating the motor, check that the drive is engaged.
ZN7 control board overview
The ZN7 has a display and ESC, arrow and ENTER buttons. Settings, timers and users are managed through the menu. The AF, Memory Roll, R700/R800, RSE and RIOCN8WS connectors have different functions; insert or remove the card only when both mains power and batteries are disconnected.
| Illustration number | Component |
|---|---|
| 1 / 2 / 3 | Motor / encoder / limit switches |
| 4 / 5 / 6 | Commands and safety devices / antenna / AF |
| 7 / 8 / 9 / 10 | Memory Roll / R700 or R800 / RSE / RIOCN8WS |
| 11 / 12 | Display / programming buttons |
| 13 / 14 / 15 | A–B–GND serial connection / A–B keypad / S1–GND transponder |
| 16 / 17 / 18 | GSM module / RGP1 / accessories and lights |
| 19 / 20 / 21 / 22 | Accessory fuse / board input / mains fuse / mains supply |
ZN7 terminals and power supply
| Terminals | Function / voltage / polarity |
|---|---|
| L / N / PE | 230 V AC mains, 50/60 Hz for BXV04AGS. PE is the protective conductor; AC has no +/− polarity. |
| 10 / 11 | Accessories: normally 24 V AC, with battery operation 24 V DC, total load max. 40 W. For DC 10 = positive (+), 11 = negative (−); no polarity for AC. |
| 10 / E | Flashing beacon or cycle light, 24 V AC/DC, max. 25 W. For DC, 10 is the positive common terminal, and E is the switched output. |
| 10 / 5 | Gate status indicator, 24 V AC/DC, max. 3 W. For DC, 10 is the positive common terminal and 5 is the switched output; not for continuous power supply. |
| 24 / 0 | Internal supply to the board from the power section; do not connect it as an accessory output or external battery input. |
| M / N | 24 V DC motor; retain the wiring for the correct assembly. Not a 230 V supply. |
| + / E / − | Encoder: +/− power supply and E signal; not a general-purpose accessory output. |
| F / FA, F / FC | F common, FA open, FC close; NC limit contacts, no polarity. |
| A / B / GND – RSE | Serial interface with the RSE card; do not confuse it with the A/B keypad connection. |
Commands and safety contacts
| Terminals | Contact / function |
|---|---|
| 1–2 | NC STOP; set F1 = ON if connected. Factory setting: F1 = OFF. No polarity. |
| 2–7 | NO command; function selected by F7. Voltage-free contact, no polarity. |
| 2–3P | NO partial or full opening, as set by F8. Voltage-free contact, no polarity. |
| 2–CX / 2–CY | NC safety inputs; set F2/F3. No polarity. |
| 10 / TS | Tested photocell power supply branch as shown in the diagram; do not enable F5 unless wired correctly. |
| A–B / R800 | Coded keypad with R800 decoding card, F14 = 1. |
| S1–GND / R700 | Transponder or reader with R700, F14 = 0. |
| Antenna / AF | RG58 and a plug-in radio card with the correct frequency/coding. |
Flashing beacon and status indicator
KLED24, 24 V AC/DC and 2 W, connect to 10–E; for the flashing beacon, set F18 = 0. KLED24 does not have a separately marked +/− supply. AC has no DC polarity; for DC, 10 is the board's positive common terminal. Do not connect a 230 V flashing beacon to this 24 V output.
Output 10–5 is for a low-power status indicator, max. 3 W, with setting F10. Cycle light mode F18 = 1 requires an automatic closing time to be set; the light stays on from opening until fully closed, including during the pause.
Photocells and safety test
CAME DIR10 consists of a TX transmitter and an RX receiver with a range of 10 m. Set the receiver jumper to 24 V. The pair draws 60 mA at 24 V AC. RX has power terminals marked 10 (+), 2 (−); TX has TX (+), 2 (−). With AC power, DC polarity does not apply. The TX terminal is part of the synchronisation circuit; do not omit this connection.
| Photocell terminal | Standard wiring | Wiring with test function |
|---|---|---|
| RX 10 (+) | Board 10 | Board 10 |
| RX 2 (−) and RX C | Board 2 | Board 2 |
| RX TX ↔ TX TX (+) | Connect TX between the receiver and transmitter | Same connection |
| TX 2 (−) | Board 2 | Board TS |
| RX NC | Board CX | Board CX |
The C–NC contact is a volt-free safety contact. It has no positive or negative polarity. The power supply and contact wiring are two separate circuits. With DC, terminal 10 is positive; the RX 2 negative terminal is connected to the board's common terminal 2 in this specific diagram. Do not confuse terminal 2 with power supply terminal 11.
For a contact on CX, set F2 = C1. For a contact on CY, select the corresponding response using F3. C1 reopens during closing; C2 recloses during opening; C3 stops and then closes automatically and requires F19; C4 waits for the obstruction to be removed, then resumes movement.
Test wiring via TS
For the test, move TX 2 to TS, while RX 2 and RX C remain connected to board terminal 2. The TX connection between the transmitter and receiver remains in place. Change the wiring with the power off first, and only then activate the test.
Set F5 = 1 for CX, 2 for CY, or 4 for both CX and CY. If the test fails, E4 is displayed and the drive will not execute the command. This function is used with active safety inputs.
After wiring, interrupt the beam during the relevant movement, then clear the obstruction. Do not bypass a safety input as a permanent fix for a fault.
Safety edges
Connect an NC contact edge between 2 and CX or CY, and select C7 – reopening during closing, or C8 – reclosing during opening. A volt-free contact has no polarity. Do not connect a resistive edge as a standard NC contact; it must have an interface compatible with the specific control unit.
Initial setup of the ZN7
- Check that the gate moves freely, the rack and fixed and switching stops are correctly positioned, the drive is secured, the wiring is correct, and hazardous areas are protected.
- Switch on the power and check the display. Set A1 = 1 for a motor up to 400 kg, F54 according to the direction and F1 according to the connected STOP.
- Set F2/F3 for the connected safety devices and, if applicable, test F5. Leave unused inputs disabled. For learning, F11 must be set to ON.
- Run A3 – travel learning.
- Set the operating parameters and users, then test a complete cycle, partial opening, each safety device, the warning light, and behaviour after a power failure.
The first normal manoeuvre after switching on the power is opening; wait for it to finish. A3 calibration has its own sequence. If you notice unusual noise, vibration, or incorrect direction, stop the drive immediately using ESC/STOP and identify the cause.
A3 – automatic travel learning
Prerequisites: A1 and F54 set correctly, STOP configured, encoder active, limit switches and fixed stops correctly set. Move the gate manually to approximately halfway and secure the drive again. Keep the area clear.
During calibration, safety devices are disabled, except for stopping with the ESC button. Monitor the entire movement and keep people out of the travel path.
- Press ENTER, use the arrow keys to select A3, then press ENTER to confirm.
- Select ON and press ENTER to confirm.
- The drive first closes to the end position; the display shows CL1.
- It then opens to the end position; the display shows OP1.
- When complete, check the full movement and safety devices. For E1/E2, first resolve the cause using diagnostics; do not repeat the learning procedure while a mechanical fault remains.
Programming via the display
Program the drive while it is stopped. ENTER opens the menu and confirms a selection; arrows </> select an item or change a value. After making a change, press ENTER to confirm. ESC cancels an unconfirmed change, goes back, or exits the menu. During normal operation, ESC stops the drive; the arrow keys allow test movement.
Factory-set values for the specified menu are shown in bold. Accessory functions appear only when the required card is installed or the related function is active. Write down the current settings before making any changes. A lower F34/F35 sensitivity number means higher sensitivity; after changing speed, torque, or sensitivity, check the forces and safety devices.
F functions
Users and system U / A / H
Pairing and deleting remote controls
The ZN7 memory can store 250 users. The receiver must be installed in the AF slot and match the transmitter's frequency and coding. An example of a fixed-code 433.92 MHz transmitter is the TOP-432EE with AF43S. U4 can limit the range of accepted code types; matching frequency alone is not enough.
- In U1, select the function: 1 step-by-step, 2 sequential, 3 open only, or 4 partial opening.
- Confirm with ENTER and send the code by pressing the selected button on the remote control.
- Repeat the procedure for each additional user. Record the storage numbers and their assigned commands, then test the actual operation.
To delete one user, use U2: Select ON, choose the number using the arrows or activate the corresponding stored transmitter, then confirm with ENTER. The display shows CLr to confirm deletion. U3 = 1 deletes all users.
U4 = 2 (Rolling Code) or 3 (TWIN) deletes previously stored transmitters using a different code. Before making a change, check the system, H1 version, and remote-control records; do not use this setting as a trial-and-error fix for a receiver fault.
Back up using Memory Roll
- Disconnect mains power and any batteries, then insert the Memory Roll into its connector.
- Switch on the power; to save data, use F50 = 1; to load data, use F51 = 1. Loading replaces the board's data with the saved data.
- When finished, disconnect the power again and remove the memory card.
- After loading, check the model, direction, safety devices, and all commands. This ZN7 has a Memory Roll connector; do not use a nonexistent USB port.
Pairing two operators
Use an RSE card in each control board and connect them using CAT 5 via A–B–GND as shown in the diagram. Connect the control and safety devices to the MASTER board. On that board, set F49 = 1, the direction in F54, and parameter transfer in F52. Store users on the MASTER; partial opening and step-by-step commands operate according to the illustrated shared system.
RIO wireless safety
RIOCN8WS uses a separate RIO connector. F65/F66 configure two wireless safety edges, and F67/F68 configure two photocell channels. Check the actual item and channel designation on the display. The wireless safety test is still active; resolve communication loss E17 or missing configuration E18 before resuming operation.
A4 – parameter reset
Before resetting, note down the H1 version, settings and users; if you have a Memory Roll, save the data. Select ON in A4 and confirm with ENTER. For the version described here, the factory settings are restored and the learned travel path is erased.
After resetting, configure A1, F54, F1, the safety inputs and A3 learning again. Check the safety devices before normal operation. Deleting users is a separate U3 function. On a control board with a different menu, A4 may restore a different range of settings; follow the instructions for the specific version.
Display-based diagnostics
| Code | Meaning / check |
|---|---|
| E1 | Calibration error. Check A3, the mechanics, direction and limit switches. |
| E2 | Configuration error. Check the A1 model, F54 direction and completion of learning. |
| E3 | Encoder error. With the power off, check the +/E/− connector and wires; after repair, perform learning. |
| E4 | Safety test error. Check TX on TS, power supply, NC and F5. |
| E7 | Operating time exceeded. Check for resistance, check the stops and confirm that movement is complete. |
| E9 | Obstacle while closing. Remove the actual obstruction; check the rack and sensitivity. |
| E10 | Obstacle while opening. Check the travel path and correct force settings. |
| E11 | Too many consecutive obstacles. Repair the mechanism or address the cause of the safety device activation. |
| E13 | Both limit contacts are open. Check FA/FC/F and switching stops. |
| E14 | Serial communication error. Check RSE, CAT 5 and configuration. |
| E15 | Incompatible transmitter. Check AF, frequency and U4. |
| E17 | Wireless system communication fault. Check RIO, devices and interference. |
| E18 | Wireless system is not configured. Check RIO and the relevant F65–F68 settings. |
If the gate does not move, check the power supply, operator release, STOP and active safety inputs, a continuously pressed button, and the transmitter battery. If it opens but does not close, check the photocells and their NC contact. Do not bypass a safety device fault with a permanent jumper.
ZN7 fuses for 230 V
| Circuit | Fast-acting fuse |
|---|---|
| Mains LINE | 1,6 A-F |
| Accessories | 2 A-F |
Check fuses with the mains and batteries disconnected. Replace only with a fuse of the same rating and type; first eliminate the cause of the short circuit or overload.
Maintenance and servicing
Regularly check that the travel path and rack are clean, the gate moves easily by hand, the operator is securely fastened, the switching stops and cables are in good condition, the release works, and the photocells and other safety devices function correctly. Disconnect the mains and any backup battery before cleaning or carrying out work. If there is damage, unusual noise or vibration, stop operation and have the cause remedied.
Set motor torque A6 and sensitivity F34/F35 according to the actual mechanism. Higher torque must not mask resistance or a fault; after adjustment, measure the forces and check the safety devices. Record the H1 version, number of manoeuvres A5 and repairs carried out in the service log.
Technical specifications of BXV04AGS
| Parameter | Value |
|---|---|
| Maximum gate leaf weight | 400 kg |
| Maximum gate leaf length | 14 m |
| Operator power supply – mains | 230 V AC, 50/60 Hz |
| Motor power supply | 24 V DC |
| Power | 170 W |
| Maximum current draw | 7 A |
| Thrust | 350 N |
| Maximum travel speed | 12 m/min |
| Operating time | 180 s |
| Protection rating | IP44 |
| Operating temperature | −20 to +55 °C |
| Operation | Intensive use; no fixed number of cycles per hour. |
| Standby power consumption | 5,5 W |
| Protection class | I |
| Pinion / limit switches | Module 4 / mechanical |
| Controls for the version described | ZN7, display + ESC/arrows/ENTER |
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]





















