Drive kit for sliding gates up to 400 kg CAME BXL04AGS, 801MS-0140 (D)
| Product availability: | within 3 days | We usually dispatch goods within 3 days. |
|---|
within 3 days
€359.87 including VAT
| Weight |
|---|
| 12 kg |
Description of Drive kit for sliding gates up to 400 kg CAME BXL04AGS, 801MS-0140 (D)
CAME BXL04AGS gate operator is designed for sliding gates weighing up to 400 kg and a passage width of up to 10 m. It has an electromechanical stop switch. The gate operator is non-reversible. Detailed technical specifications ». Download the manual ».
BXL04AGS with ZN6 control board is a sliding gate operator with a 24 V DC motor and mechanical limit switches. The mains supply is 230 V AC. Consider the gate’s weight, length, and resistance together; the operator is not a solution for a gate that moves with difficulty or is damaged.
Disconnect the mains supply and any batteries before carrying out any work. The encoder and photocells do not replace fixed stops, protection at hazardous points, or force testing on the completed gate.
Check the control board before programming. The following settings apply to the ZN6 with five DIP switches, three trimmers, and a P1 button. If the operator has a different control board or a display, do not use these DIP switch combinations.
CAME BXL04AGS kit
The kit includes a 24 V motor, remote control, photocells, radio receiver, and warning light. Select additional components, especially the toothed rack and supplementary controls, to suit the specific gate. Check the control unit and supplied components before wiring.
| Feature | CAME BXL04AGS |
|---|---|
| Kit | ![]() BXL04AGS / 801MS-0140 (D) |
| Max. gate leaf | 400 kg / 10 m |
| Motor / power | 24 V DC / 150 W |
| Control unit covered in this guide | ZN6: DIP switches, P1, trimmers |
| Operation | Duty cycle 50% |
| Radio memory | 25 users |
Compatible accessories
| Item | Why | Type |
|---|---|---|
| Photocells | Monitor the passage; select the safety input response. |
|
| Warning light | Signals gate movement. |
|
| Receiver | Radio control with matching coding. |
|
| Remote control | An additional transmitter for a compatible fixed-code system. |
|
| Rack | Transfers movement to the gate leaf. |
|
| Push button / key switch | Local command or STOP. |
|
Installing the operator
With the operator released, the gate must move easily along its entire travel, without a slope, damaged wheels, or any risk of coming off its track. Check that fixed mechanical stops are installed at both the open and closed positions, that the base is stable, and that areas where the gate leaf could trap someone are protected. There must be no standing water in the operator area, and the operator must not be exposed to a direct jet of water.
Foundation and anchor plate
The installation example shows an excavation 450 × 300 mm and 400 mm deep. Size the foundation to suit the ground conditions and the specific gate. The formwork extends 50 mm above ground level; use reinforcement and M12 anchors. A Ø 40 mm conduit is recommended for the operator supply cable and a Ø 25 mm conduit for accessories.
Install the anchor plate level, route the cables through its openings, and leave the threaded parts of the anchors above the surface. Allow the concrete to cure for at least 24 hours. Position the plate relative to the rack according to the dimensioned drawing; the pinion height differs between these two operators.
Installation and height adjustment
Remove the cover and fit the operator onto the plate. The cables must pass through the underside of the housing and through correctly fitted cable glands. During adjustment, raise the operator using the threaded feet by 5–10 mm, leaving room to adjust the mesh.
Rack and pinion clearance
Release the operator and attach the rack while moving the gate leaf by hand. When joining sections, place a short piece of rack under the joint to ensure the teeth mesh smoothly. After installation, adjust the operator’s vertical and horizontal position.
Leave 1–2 mm of clearance between the rack and pinion. The gate’s weight must not rest on the operator. Move the gate through its full travel by hand and check the mesh and rack joints; only then tighten the nuts and washers on the anchors.
Mechanical limit switches
Move the gate leaf by hand to the open position. Attach the opening limit-switch cam to the rack so that its ramp reliably actuates the spring-loaded microswitch. Set the closing limit-switch cam in the same way. Secure the cams firmly; the gate’s fixed mechanical stop and the operator’s limit-switch cam serve different purposes.
Set the cut-off so that the operator does not push the gate leaf against the fixed mechanical stop during normal opening or closing.
Wiring
| Connection | Cable / condition |
|---|---|
| 230 V AC mains, L/N/PE | 3G × 1.5 mm² for lengths up to 20 m; 3G × 2.5 mm² for 20–30 m. |
| Warning light / command | 2 × 0.5 mm²; check the conductor cross-section for the specific load and cable length. |
| DIR10 photocells | TX: 2 × 0.5 mm²; RX: 4 × 0.5 mm², according to the synchronised DIR wiring diagram. Also connect the TX link and the NC contact. |
| Antenna | RG58; recommended length up to 5 m. |
The number of conductors must cover the entire selected wiring diagram. For longer cable runs, simultaneous loads or other accessories, recalculate the conductor cross-section based on the current and voltage drop. Protect cables from damage and contact with the motor or transformer; route the mains supply and low-voltage circuits appropriately separated.
Manual release during a power failure
Disconnect the power and secure the gate leaf before moving it manually. Releasing a damaged or unbalanced gate may cause uncontrolled movement.
- Insert the key into the lock and turn it clockwise.
- Pull and open the release lever as shown.
- Move the gate manually in a controlled manner, with no people in its path.
- To re-engage the mechanism, return the lever to its original position and lock the mechanism. Before issuing a motor command, check that the drive is engaged.
ZN6 control board overview
The ZN6 has five DIP switches, A.C.T., SP.SLOW and SENS. trimmers, a P1 programming button and a command button 7. The LEDs indicate the power supply, commands and safety inputs. Radio control requires a plug-in card in the AF connector; the R800 is used for a compatible coded keypad.
| Figure number | Component |
|---|---|
| 1 / 2 / 3 | DIP switches / trimmers / P1 |
| 4 / 5 | LED / command button 7 |
| 6 / 7 / 8 | Encoder and limit switches / commands and safety / A–B keypad |
| 9 / 10 / 11 | Motor M–N / accessories / board internal power supply |
| 12 / 13 / 14 | Accessory fuse / antenna / AF |
| 15 / 16 | RGP1 / R800 |
| 17 / 18 | Mains terminal block / mains fuse |
ZN6 terminals and power supply
| Terminals | Use / voltage / polarity |
|---|---|
| L / N / PE | 230 V AC mains, 50/60 Hz; connect the PE protective conductor. AC, no +/− polarity. |
| 10 / 11 | 24 V AC/DC accessories, maximum total load 20 W. For DC: 10 = positive (+), 11 = negative (−); for AC, no polarity. |
| 10 / E | 24 V AC/DC warning light output, max. 25 W; for DC, common terminal 10 is positive and E is the switched output. This is not a permanent power supply for accessories. |
| 24 / 0 | Board internal 24 V AC/DC power input; do not connect it to the accessory output. For AC, there is no polarity; for DC, 0 = +, 24 = −. |
| M / N | 24 V DC motor; wire according to the original diagram. Not 230 V mains. |
| + / E / − | Encoder: +/− power supply and E signal; not an accessory output. |
| F / FA, F / FC | Limit switches: FA open, FC close, F common; NC contacts have no polarity. |
Commands, STOP and keypad
| Terminals | Contact / function |
|---|---|
| 1–2 | NC STOP. Enabled by default; if there is no STOP, disable it using DIP switches 2 and 3. Contact has no polarity. |
| 2–7 | NO command, set by default to open – close – reverse direction. No polarity; do not connect an external power supply. |
| 2–3P | NO partial opening; opens in hold-to-run mode. No polarity. |
| 2–CX | NC safety contact; enable and select C1/C4. |
| 10–TS | Power output for the photocell branch being tested, according to the specific wiring diagram. |
| A–B | Compatible keypad with an R800 card, not motor terminals. |
| Antenna / AF | RG58 / plug-in radio card. Insert only when the mains and battery power supplies are disconnected. |
24 V warning light
KLED24 connect to 10–E. It operates on 24 V AC/DC and has a power consumption of 2 W. With AC, the supply has no DC polarity; with DC, terminal 10 on the board is positive and E is the switched output. The KLED24 supply terminals are not marked separately as +/−. A 230 V warning light must not be connected to this output.
Photocells and safety test
CAME DIR10 consists of a TX transmitter and an RX receiver with a range of 10 m. Set the receiver jumper to 24 V. The pair draws 60 mA at 24 V AC. The RX power supply terminals are marked 10 (+), 2 (−); the TX terminals are TX (+), 2 (−). With AC power, DC polarity does not apply. The TX terminal is part of the synchronisation circuit; do not omit its connection.
| Photocell terminal | Standard wiring | Wiring with test |
|---|---|---|
| RX 10 (+) | Board 10 | Board 10 |
| RX 2 (−) and RX C | Board 2 | Board 2 |
| RX TX ↔ TX TX (+) | Connect TX between the receiver and transmitter | Same connection |
| TX 2 (−) | Board 2 | Board TS |
| RX NC | Board CX | Board CX |
The C–NC contact is a volt-free safety contact. It has no positive or negative polarity. The power supply wiring and the contact are two separate circuits. With DC, terminal 10 is positive; the negative RX 2 lead is connected to the board’s common terminal 2 in this specific diagram. Do not confuse terminal 2 with power supply terminal 11.
Enable the connected CX input using DIP 4. For protection while closing, leave the response set to C1; use DIP 1,4 to select C4. C1 reopens the gate if the beam is interrupted while closing; C4 stops movement and resumes after the obstruction is removed.
The original ZN6 diagrams below show synchronized DN10 photocells. The DIR10 terminal layout above is also based on its own wiring diagram. Do not use this terminal layout for photocells with different labels or a different interface.
Wiring the test via TS
For the test, move TX 2 to TS, while RX 2 and RX C remain on board terminal 2. The TX link between the transmitter and receiver remains in place. First change the wiring with the power off, and only then enable the test.
Enable the test via DIP 2,4 and P1; the CX input must be enabled. If the test fails, the board will not execute the command. After setup, return all DIP switches to OFF.
After wiring, test by interrupting the beam during the relevant movement and then clearing it. Do not bridge the safety input as a permanent fix for a fault.
Initial ZN6 startup
- Check the mechanics, rack clearance, fixed and switching stops, drive locking, and all connected safety devices.
- Switch on the power and check the PWR LED. Set, in order, travel direction, STOP and travel learning.
- Enable the connected CX, set its response, and configure the photocell test if required. Leave unused CX disabled.
- Set and save the trimmers, any automatic operation, and partial opening.
- Pair the remote controls. Check the complete cycle, STOP, photocells, slow-down, end positions, warning light, and behavior after a power failure.
Automatic full travel learning
Requirements: correct direction and STOP, active encoder, clear travel path, and correctly set limit switches. After manual movement, the drive must be locked again. Supervise the entire movement; do not enter the gate area during learning.
- With the drive stopped, set DIP 1,2,3,5 to ON; DIP 4 remains OFF.
- Press P1. The gate will make a series of movements to determine the slow-down points.
- The red LED flashes during learning. Successful completion is confirmed by a 1-second beep; failure is indicated by rapid flashing and 4 beeps.
- P1 can interrupt learning. After completion, return all five DIP switches to OFF.
- Check the full opening and closing cycle and the operation of the safety devices. If an error occurs, first remove its cause, then repeat the learning procedure.
Learning the partial opening position
After learning the full travel, use button 7 on the board to move the gate to the desired partial position. Set DIP 4,5 to ON and press P1. The LED lights up and a 1-second beep confirms that the position has been saved. Rapid flashing with four beeps indicates an invalid position. Then return the DIP switches to OFF and test the 2–3P command and partial-position automatic operation.
Programming with DIP switches and the P1 button
The DIP switches select the function, which you save by pressing P1. They are not permanent operating switches. For each setting, set only the numbers specified in the relevant row to ON; all others must be OFF. Program only when the drive is stopped. After confirmation, return all five DIP switches to OFF.
When switching to an active or alternative function, the LED lights up and a 1-second beep sounds; when switching back to the disabled or original setting, the LED flashes and two beeps sound. STOP, the encoder, and automatic partial-stop operation are enabled by default, so the first press of P1 disables them. Learning, pairing, deletion, and reset have their own confirmations, as shown in the table.
Trimmers and saving values
| Trimmer | Range / purpose |
|---|---|
| A.C.T. | Automatic closing delay 1–120 s; enable automatic closing with a separate function. |
| SP.SLOW | Deceleration speed 30% (−) to 60% (+) of the maximum speed. |
| SENS. | Obstacle detection sensitivity: − minimum, + maximum sensitivity. After changing the setting, check the forces and safety functions. |
After adjusting the trimmers, save all three values: Set DIP switches 2,3,4,5 to ON, press P1, confirm with the LED and a 1 s beep, then set all DIP switches to OFF. Changes will be lost if they are not saved.
Pairing remote controls
ZN6 stores up to 25 users. For a 433.92 MHz fixed-code system, you can use AF43S and a compatible TOP-432EE. Insert the AF card only when the power is off. The same frequency alone does not guarantee compatible coding.
- Select the DIP combination for the required command: 1 = partial opening; 2 = open only; 1,2 = open–close–change direction; 3 = open–STOP–close–STOP.
- Press P1. When the LED starts flashing, within 10 seconds press the selected remote-control button.
- The LED lights and a 1 s beep confirms that it has been saved. A transmitter that is already saved is indicated by rapid flashing and 4 beeps.
- Set all DIP switches back to OFF and check the assigned function.
Deleting remote controls and resetting
Delete all users: Set DIP switches 1 and 3 to ON, all others to OFF; hold P1 for 5 s. The LED lights and a 1 s beep confirms deletion. Then set the DIP switches to OFF. This removes all saved remote controls.
Reset parameters: Set all five DIP switches to ON and press P1. The LED flashes and two beeps sound; then set all five DIP switches to OFF. Resetting does not erase user settings. Before using it again, set and check the direction, STOP, CX, learning and safety settings again.
ZN6 diagnostics
| LED | Meaning / what to check |
|---|---|
| CX – yellow | On when NC contact 2–CX is open. Photocell beam, power supply and contacts. |
| 1 – yellow | On when NC contact 1–2 is open. STOP and its configuration. |
| 3P – yellow | On when NO contact 2–3P is closed; if it stays on, check for a command stuck on. |
| 7 – yellow | On when NO contact 2–7 is closed; check the button/switch. |
| PRG – red | Programming, waiting for automatic closing or a fault. The meaning depends on the procedure in progress. |
| PWR – green | Board power supply. If it is off, check the power supply and fuses. |
| Symptom | Check / remedy |
|---|---|
| 4 beeps during learning | Check the learning procedure, direction, limit switches, free movement and encoder. |
| 4 beeps during pairing | The transmitter is already stored; this does not confirm a new one has been stored. |
| 4 beeps at partial opening position | Select another permitted partial opening position. |
| Does not move | Check the power supply, drive release, STOP, activated CX, TS test and any commands that are permanently closed. |
| Opens but does not close | Check the photocells and their NC contact; for automatic operation, also check that it is enabled and that A.C.T. is stored. |
ZN6 fuses
| Circuit | Fast-acting fuse |
|---|---|
| Mains LINE | 1.6 A-F |
| Accessories | 2 A-F |
Check fuses with the power disconnected. Use the same rating and fast-acting type; a higher-rated fuse or repeated replacement without eliminating the short circuit is not a repair.
Maintenance and servicing
Regularly check that the track and rack are clean, movement by hand is smooth, the drive is securely fastened, the limit stops, cables, release mechanism, photocells and other safety devices are in good condition. Disconnect the mains and any backup battery before cleaning or carrying out work. If there is damage, unusual noise or vibration, stop operation and have the cause rectified.
Increasing SENS. sensitivity does not replace mechanical repairs; trimmer settings must be saved using DIP 2,3,4,5 and P1. After servicing, check the full travel, forces and safety devices again.
BXL04AGS technical specifications
| Parameter | Value |
|---|---|
| Maximum gate leaf weight | 400 kg |
| Maximum gate leaf length | 10 m |
| Drive power supply – mains | 230 V AC, 50/60 Hz |
| Motor power supply | 24 V DC |
| Power | 150 W |
| Maximum current draw | 7 A |
| Ingress protection rating | IP44 |
| Operating temperature | −20 to +55 °C |
| Operation | Duty cycle 50%; this is not the number of cycles per hour. |
| Standby power consumption | 7.4 W |
| Protection class | I |
| Pinion / limit switches | Module 4 / mechanical |
| Control unit for the specified version | ZN6, DIP switches + trimmers + P1 |
| Drive unit weight | 7.7 kg |
How can I order this item?
Choose the option that suits you:
- order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
- order by email: place your order at [email protected]