Drive kit for sliding gates up to 400 kg CAME BX704, 801MS-0020 (D)


Product availability: within 3 days

We usually dispatch goods within 3 days.


Drive kit for sliding gates up to 400 kg CAME BX704, 801MS-0020 (D) Drive kit for sliding gates up to 400 kg CAME BX704, 801MS-0020 (D)
CAME-BX704AGS-D
within 3 days
€394.83 excluding VAT
€485.64 including VAT

 pcs
Weight
16 kg

Description of Drive kit for sliding gates up to 400 kg CAME BX704, 801MS-0020 (D)

CAME BX704AGS gate operator is designed for sliding gates weighing up to 400 kg and a gate leaf length of up to 14 m. It has an electromechanical stop switch. The operator is non-reversible. Detailed technical specifications ». Download the manual ».

CAME BX704AGS and ZBX7N control unit

The kit includes an operator for a sliding gate weighing up to 400 kg with mechanical limit switches. The motor and power supply are 230 V AC; accessories are powered from a separate output 24 V AC. The built-in encoder enables travel learning, obstacle detection and adjustable deceleration.

Before adjusting settings, check the exact operator, the ZBX7N marking on the board and the firmware version in H1. The table below is for an older control unit version with F8 options 0 = partial opening / 1 = full opening. Matching F8 alone does not confirm that the entire version is the same. Boards with the same name and the same F8 options may still behave differently in terms of memory or technical specifications. Before making changes, compare the settings and procedure with the manual supplied with the specific board. If F8 has options 1/2, do not use the numbers and factory settings listed below. Do not confuse operators with a 230 V mains motor with 24 V models.

Disconnect the power before handling terminals or plug-in cards. The operator must not be used in place of missing mechanical stops or to overcome faulty gate mechanics.

Quick navigation
Kit contentsBX704 kit
AccessoriesSelection and load
Operator installationRack and stops
Board and terminalsDIR10 photocells
Initial startupTravel learning
Buttons and menuF functions
Remote controlsDiagnostics
Reset and memoryMaintenance
Specifications and dimensionsPDF manual

What's included in the kit

BX704AGS operator with built-in ZBX7N control board, limit stops for switching, radio receiver card AF43S, remote control TOP44RBN, pair of photocells DIR10 and flashing light KLED230. The toothed rack is selected to suit the gate; it is not included in this kit.

CAME BX704 kit

FeatureCAME BX704AGS
KitCAME BX704AGS kit
BX704 – up to 400 kg
Gate leaf weightmax. 400 kg
Gate leaf lengthmax. 14 m
Motor and board230 V AC / ZBX7N
Limit switchesmechanical
Included equipmentAF43S, TOP44RBN, DIR10, KLED230

Choose based on the actual weight, length, movement resistance and number of cycles; weight alone is not enough.

Accessories – what they are, why you need them and types

WhatWhyType
PhotocellsProtect the passage area while the gate is closing.
Remote controlCommand for full or partial travel.
Radio receiver cardReceives the remote control's signal.
  • AF43S in the AF connector; ZBX7N manages codes and users. Frequency alone does not determine compatibility.
Flashing lightSignals that the gate is moving.
Toothed rackTransfers movement to the gate leaf.
Button / key switchLocal control or partial opening.
Safety edgeProtection against crushing at hazardous points.
Serial interfaceConnecting two operators or CRP communication.
  • RSE in the appropriate slot, A/B/GND; MASTER/SLAVE. It is not a standard radio receiver.

Operator selection and load

The maximum gate leaf weight is 400 kg, maximum length 14 m. When unlocked, the gate must move smoothly along its entire travel and have mechanical stops in both directions. If the gate jolts, sticks or encounters increased resistance, repair the guides and mechanics first.

17 cycles per hour and 6 consecutive cycles apply to a reference gate leaf length of 4 m, a temperature of 20 °C and a correctly installed gate without additional friction. These values do not apply to every gate length up to 14 m. For longer gate leaves and higher temperatures, the permitted number of cycles decreases, as shown in the original graphs.

Cycles per hour by gate-leaf length and temperature

Consecutive cycles by gate-leaf length and temperature

Do not extrapolate the graphs beyond the last plotted point. Cycles per hour is an operating limit, not a service-life guarantee.

Drive installation and wiring

  1. Check the gate leaf's stability, rollers, track or guide, smooth movement, and secure mechanical stops. Secure hazardous areas at the rack and pinion.
  2. Choose a solid base protected from impacts and direct water spray. Install conduits; Ø 40 mm is recommended for the drive and Ø 25 mm for accessories.
  3. The foundation formwork must be larger than the anchor plate and extend 50 mm above ground level. Add steel reinforcement. Secure the M12 bolts to the plate and route the conduits through its openings.
  4. For an existing rack, follow the original dimensional detail of 84 / 105 mm. Level the plate and set it in concrete; allow at least 24 hours for curing.
  5. Leave approximately 600 mm of cable protruding. Remove the covers, place the drive on the plate and use the adjustable feet to raise it by 5–10 mm before initially levelling it, leaving room for adjustment.

Preparing the foundation and securing the anchor plate

Plate installation dimensions for an existing rack

Recommended minimum cross-sections

Cable runLess than 20 mMore than 20 m and less than 30 m
230 V AC supply, L/N/PE3G × 1.5 mm²3G × 2.5 mm²
Warning light2 × 0.5 mm²2 × 0.5 mm²
Control contact2 × 0.5 mm²2 × 0.5 mm²
TX photocell2 × 0.5 mm²2 × 0.5 mm²
RX photocell4 × 0.5 mm²4 × 0.5 mm²

Use H05RN-F for outdoor mains wiring and H05VV-F for indoor wiring; for low-voltage wiring up to 48 V, use FROR 20-22 II as appropriate. Antenna: RG58, recommended maximum length 5 m. Serial connection: UTP CAT5, maximum 1,000 m. For other distances, multiple loads, or a test cable, add the required conductors and cross-section according to the actual load and wiring configuration.

Route cables through separate cable glands; they must not touch the motor or transformer. The mains supply must have a suitable two-pole disconnect and a PE protective conductor.

Rack, clearance and end positions

  1. Disengage the drive. Fit the module 4 rack along the entire length of the gate. When joining sections, align the teeth using a spare piece of rack beneath the joint.
  2. Move the gate manually through its entire travel. Adjust the height using the feet and the lateral position using the anchor slots; leave a gap of 1–2 mm. The gate leaf's weight must not rest on the drive.
  3. Once level, firmly tighten the drive fasteners.
  4. Open the gate manually. Slide the opening limit switch on the rack until it activates the microswitch spring, then secure it.
  5. Set the closing limit switch in the same way. According to the dimensional detail, leave approximately 20 mm. Check both directions and re-engage the drive.

Installing and aligning the toothed rack

Setting the 1–2 mm clearance between the rack and pinion

Setting the mechanical limit switch for opening

Setting the mechanical limit switch for closing

Manual release during a power failure

  1. Disconnect the power and secure the gate leaf against moving on its own.
  2. Open the lock cover, insert the key and unlock the release hatch.
  3. Open the hatch and turn the release control within the open hatch area, following the arrow shown in the illustration. You can now move the gate manually.
  4. To re-engage the drive, turn the control back as shown in the locking illustration, close the hatch, lock it with the key and close the lock cover.
  5. Check that the drive is engaged before restoring power. An open hatch may trigger E8.

Manual release of the CAME BX drive

Re-engaging the CAME BX drive

ZBX7N board orientation and terminals

In the illustration, the board is shown with the terminal blocks at the top and the buttons ESC / < / > / ENTER at the bottom right. The display is at the bottom; PWR indicates that power is present. The circled numbers identify board components, not electrical terminal numbers.

ZBX7N board – terminal blocks, connectors, fuses and buttons

Position in the illustrationBoard component
1 / 2 / 3Mains supply / motor / transformer.
4 / 6 / 22Board / accessory / mains fuse.
5Control and safety inputs.
7RGP1: + / STB / −, energy-saving module; not a battery input.
8 / 10 / 11Encoder / mechanical limit switches / antenna.
9 / 13 / 15Keypad / transponder terminals; R700 or R800 decoder socket.
12AF radio card.
14 / 17Serial terminals A/B/GND / RSE socket.
16RIO-CONN socket for RIOCN8WS.
18 / 19 / 20 / 21Programming buttons / Memory Roll / display / PWR LED.

Power supply, motor and encoder

TerminalsConnection and rating
L / N / PEL = live, N = neutral; 230 V AC, 50/60 Hz. Connect the PE protective conductor to the marked earth point. This is not +/−.
U / V / WFactory motor wiring and capacitor; 230 V AC motor. It does not use DC polarity. To select the direction, use F54; do not swap the wiring by guesswork.
+ / E / DEncoder – factory wiring: + = red wire, E = black wire, D = shield, according to the original diagram. When reconnecting, follow the labels and original wiring; do not assign a different function to E or D based on wire color. These terminals are not a power supply for photocells; do not connect an external power source here.
FC / FA / FFC = closing limit switch; FA = opening limit switch; F = common wire. Do not confuse the factory wiring with the accessory power supply.
10 / 1124 V AC, max. 20 W for accessories. AC voltage has no positive or negative terminal.
TSTest terminal for photocells; used with F5 and a specific test wiring diagram. It is not a replacement for a permanent power output.

Original wiring for the motor, encoder, capacitor and limit switches

Mains supply, 24 V AC output and transformer torque setting

Buttons, STOP and safety inputs

InputContact / use
1–2STOP with a volt-free contact NC, enable F1. Opening the contact stops the gate and disables automatic closing; operation resumes with a new command.
2–7Volt-free contact NO; command according to F7. With F6 = ON, this is a maintained closing command.
2–3PVolt-free contact NO; partial or full opening according to F8. With F6 = ON, this is a maintained opening command.
2–CX / 2–CYSafety contact NC, response according to F2/F3. The contact is non-polarized; do not connect an external voltage to it.
A / B – keypadCode selector with R800 decoder; set F14 = 1.
S1 / GNDTransponder or reader with R700; set F14 = 0. The original diagram shows the red wire connected to S1 and the black wire to GND.
AntennaRG58: connect the center conductor to the antenna signal input and the shield to the terminal marked with the shield symbol.

Wiring for buttons, STOP, antenna and plug-in radio/access-control cards

NO means open at rest, NC means closed at rest, and the contact's common terminal is COM/C. For a standard command, do not connect 230 V mains voltage to inputs 2–7 or 2–3P. Disable an unused STOP input using F1; disable unused CX/CY inputs using F2/F3. Do not disable connected safety devices as a way to fix a fault.

Flashing light and status indication

OutputVoltage / power / mode
W–E1KLED230: 230 V AC, output limit 25 W, F18 = OFF. For cycle lighting 230 V AC, max. 60 W, F18 = 1 and F19 enabled. AC, no +/−; do not use a 24 V flashing light here.
11–FAGate-open indicator: 24 V AC, max. 3 W, no +/−.
11–FCGate-closed indicator: 24 V AC, max. 3 W, no +/−.

Outputs for flashing light or cycle light, and for gate-open/gate-closed indication

CAME DIR10 photocells

DIR10 consists of a synchronized transmitter (TX) and receiver (RX), with a range of 10 m. For this wiring, set the photocells to 24 V; the supply is 24 V AC. The pair draws 60 mA at 24 V AC. In the original diagram, RX terminal 10 and TX terminal TX are marked +, and terminals 2 are marked −; when powered from the control board, the supply is AC with no DC polarity. Follow the specific TX synchronization wiring, not just the pair of power wires.

DIR10 terminalStandard wiringWiring with test
RX 10 (marked +)ZBX7N 10ZBX7N 10
RX 2 (marked −)ZBX7N 2ZBX7N 11
RX TX ↔ TX TX (marked +)Connect TX between the RX and transmitterSame connection
TX 2 (marked −)ZBX7N 2ZBX7N TS
RX C – common contactZBX7N 2ZBX7N 11
RX NC – safety contactZBX7N CX, or CYZBX7N CX, or CY
FunctionsF2 = C1 (for CX), F5 = OFFF2 = C1 (for CX), F5 = 1
For input CYF3 = selected responseF3 = selected response; F5 = 2, or 4 when testing both CX and CY

With C1, opening the contact while closing triggers opening. C2 triggers closing during opening; C3 stops movement and is followed by automatic closing; available only when F19 is active. C4 stops movement and resumes it once the obstacle is removed. Select the response according to the area being protected. After wiring, check operation by interrupting the beam during the relevant movement.

DIR10 / DELTA-S – standard wiring to ZBX7N

DIR10 / DELTA-S – wiring with test via TS

Testing is not just a menu setting. First connect the terminals according to the test wiring diagram, then enable F5. If the test fails, the control board will not execute the command and will display E4. DELTA has different terminals; do not use this DIR10 terminal list for it.

Safety edges

Connect the DFWN edge with a volt-free NC contact between 2 and CX/CY, and select C7 or C8. For the DFI interface, use the separate power supply and contacts shown below; the edge itself with an NC contact is not powered this way. Options r7/r8 are intended for the corresponding 8.2 kΩ resistive edge, not for an arbitrary contact. The specific type, location, and resulting force must be verified by a safety test.

Original DFI terminalZBX7N / safety edge
24V / 0VDFI 24V → ZBX7N 10, DFI 0V → ZBX7N 11. The power supply in this diagram is 24 V AC, with no DC polarity +/−; the 12V terminal remains unused. The total output limit for accessories across terminals 10–11 is 20 W.
Pair of terminals with a contact symbolIn the original diagram, immediately to the right of 0V: left → ZBX7N 2, right → CX or CY. A volt-free safety contact has no polarity; set the response via F2/F3.
C / NO / NCConnect the DFI terminals with the same labels to the DFWN edge’s C / NO / NC terminals as shown in the diagram. Do not confuse these with the separate pair of output-contact terminals to the control board.

Original wiring of the DFWN contact edge and DFI interface

First startup

  1. Check the mechanical stops, limit switches, that the drive is properly locked, cable protection, and safety wiring.
  2. Switch on the power; check the PWR LED and display operation. In A1, check 1 = BX704AGS.
  3. Set F54 according to the actual direction of travel, and F1 according to the connected STOP button. Configure CX/CY and, if applicable, the F5 test. Leave F11 = ON for learning.
  4. Run A3 – travel learning.
  5. Set only the required operating functions, add the transmitters, and test the full travel, partial opening, STOP, photocells, edges, and warning light.

The first normal operation after switching on the power is opening. At this stage, wait until the gate is fully open; closing is not available. A3 calibration has its own sequence, shown below. If there is unusual noise, vibration, or incorrect movement direction, press ESC/STOP immediately and resolve the cause.

A3 – automatic travel learning

Requirements: F11 = ON, correct A1 and F54 settings, limit switches set, both fixed mechanical stops in place, and the gate leaf approximately halfway along its travel. After moving it manually, lock the drive again. Ensure the entire travel path is clear.

Safety devices are disabled during calibration. Supervise the entire movement directly and prevent people from entering the gate area.

  1. Hold ENTER for at least 1 second, use the arrows to select A3, and confirm with ENTER.
  2. Select ON and confirm with ENTER.
  3. The gate first closes to the limit position; the display shows CL1.
  4. Then it opens to the limit position; the display shows OP1. Do not enter the travel path.
  5. When finished, check a full cycle, stopping, and the selected response of each safety device. For E1 or E2, address the cause using the diagnostics and repeat calibration only after the problem has been resolved.

A3 calibration sequence: closing CL1 and opening OP1

Programming using the display

Make adjustments with the drive stopped. Hold ENTER for at least 1 second, use the </> arrows to select a function, and press ENTER to open its value. Use the arrows to change the value, then press ENTER to confirm and save it. ESC cancels an unconfirmed change and exits the menu; the menu also closes after 10 seconds of inactivity. Do not assume an unconfirmed change has been saved.

Display and ESC, arrow, and ENTER buttons

Outside the menu, the arrows move the gate during testing and ESC stops it. Check programming values and confirmation on the display. The PWR LED indicates that power is present.

F functions – complete settings

Factory settings for the ZBX7N version shown are in bold. Function availability depends on the connected card, activated encoder, and related functions. Record the original settings before making changes. Do not set F34/F35 sensitivity or starting torque based on the maximum weight; after adjustment, you must check the forces and safety protection.

Function and meaningValues / factory setting
F1 – Full stop
Input 1–2 with an NC contact. After STOP, the gate does not close automatically; a new command is required. Leave OFF if there is no STOP button.
OFF – disabled
ON – active
F2 – CX safety input
Input 2–CX. C1 to C4 for photocells, C7/C8 for a contact edge, and r7/r8 for a resistive edge. C3 is displayed only when F19 is active.
OFF – disabled
1 = C1 – reopen during closing
2 = C2 – reclose during opening
3 = C3 – stop, then close automatically
4 = C4 – stop and resume after the obstacle is removed
7 = C7 – edge: reopen during closing
8 = C8 – edge: reclose during opening
r7 – 8.2 kΩ resistive edge, reopen during closing
r8 – 8.2 kΩ resistive edge, reclose during opening
F3 – CY safety input
Input 2–CY; the same available responses as for CX. C3 is displayed only when F19 is active.
OFF – disabled
1 = C1 – reopen during closing
2 = C2 – reclose during opening
3 = C3 – stop, then close automatically
4 = C4 – stop and resume after the obstacle is removed
7 = C7 – edge: reopen during closing
8 = C8 – edge: reclose during opening
r7 – 8.2 kΩ resistive edge, reopen during closing
r8 – 8.2 kΩ resistive edge, reclose during opening
F5 – Photocell test
Checks the connected photocells before movement. Requires connection via TS. Available after photocells are activated; wireless safety devices are always tested.
OFF – disabled
1 – CX
2 – CY
4 – CX and CY
F6 – Hold-to-run button operation
Opening via 2–3P and closing via 2–7 are enabled only while the button is held. All other commands, including radio controls, are disabled in this mode.
OFF
ON
F7 – Command 2–7
Defines the function of the button or switch on input 2–7.
0 – step-by-step: open – close – change direction
1 – open – STOP – close – STOP
2 – open only
3 – close only
F8 – Command 2–3P
Partial or full opening. The numbers apply to a board with a 0/1 menu.
0 – partial opening
1 – open
F9 – Obstacle with motor stopped
If the gate is stopped in the open or closed position, or after a full STOP, and a safety device detects an obstacle, a command will not set it in motion.
OFF
ON
F11 – Encoder
Controls deceleration, obstacle detection and sensitivity. Travel path A3 must be learned before enabling this function.
OFF
ON – enabled
F14 – Control device type
For a reader/transponder with R700 or a keypad with R800; this is not a setting for a standard button.
0 – transponder or card reader
1 – keypad
F18 – W–E1 light
The beacon flashes while the gate is moving. The cycle light remains on from the start of opening until the gate is fully closed, including during the waiting period; this mode requires F19.
OFF – beacon
1 – cycle lighting
F19 – Automatic closing
Waiting time after full opening. Automatic closing does not operate after a full STOP, a power failure, or activation of a safety device that detects an obstacle.
OFF – disabled
1 to 180 – time in seconds
F20 – Closing after partial opening
Time after partial opening. The same limitations apply after a STOP, power failure or safety-device obstacle detection.
OFF
1 to 180 s
10 s – factory setting
F21 – Pre-flashing
W–E1 beacon time before movement starts.
OFF
1 to 10 s
F30 – Deceleration speed
Common setting for opening and closing. Displayed when encoder F11 is active.
OFF – no deceleration
1 – high
2 – medium
3 – low
F34 – Sensitivity during travel
Obstacle detection during normal movement; only with F11. A lower number means higher sensitivity.
10 to 100
10 – highest sensitivity
100 – lowest sensitivity
F35 – Sensitivity during deceleration
Only with F11 and F30 active; a lower number means higher sensitivity.
10 to 100
10 – highest sensitivity
100 – lowest sensitivity
F36 – Partial opening range
Percentage of the total learned travel path. Only with F11 active; when the encoder is disabled, F71 is used.
10 to 80% of travel
80% – factory setting
F37 – Deceleration during opening
Travel range for deceleration before the open end position. Only with F11 and F30.
5 to 30% of travel
15% – factory setting
F38 – Deceleration during closing
Travel range for deceleration before the closed end position. Only with F11 and F30.
5 to 30% of travel
15% – factory setting
F48 – Increased starting torque
Increased force at the start of opening and closing. Does not replace correcting mechanical resistance in the gate.
OFF
ON
F49 – Serial connection
Uses an RSE card. Pairing two operators or CRP communication.
OFF
1 – paired operators
3 – CRP
F50 – Save to Memory Roll
Saves users and settings. Displayed only when a memory card is inserted.
OFF
ON – save
F51 – Load from Memory Roll
Loads saved users and settings onto the control board. Displayed only when a memory card is inserted.
OFF
ON – load
F52 – Transfer MASTER → SLAVE
Transfers the parameters from the master control board to the other board. Only when F49 = 1.
OFF
ON – transfer
F54 – Sliding direction
Selects left- or right-hand travel according to the actual installation.
0 – left
1 – right
F56 – CRP address
A unique board address when multiple operators are connected via CRP.
1 to 255; each board on the shared connection must have its own address.
F63 – Communication speed
Baud rate of the CRP serial connection.
0 – 1,200 baud
1 – 2,400 baud
2 – 4,800 baud
3 – 9,600 baud
4 – 14,400 baud
5 – 19,200 baud
6 – 38,400 baud
7 – 57,600 baud
8 – 115,200 baud
F65 – RIO-EDGE T1
Wireless safety edge, only with RIOCN8WS in RIO-CONN.
OFF
P0 – STOP without automatic closing; resume with a new command
P7 – reopen during closing
P8 – close again during opening
F66 – RIO-EDGE T2
Second wireless safety edge channel; only with RIOCN8WS.
OFF
P0 – STOP without automatic closing; continue with a new command
P7 – reopen during closing
P8 – close again during opening
F67 – RIO-CELL T1
Wireless photocells; only with RIOCN8WS. P3 is available only with F19.
OFF
P1 – reopen during closing
P2 – close again during opening
P3 – stop, then close automatically
P4 – stop and resume after the obstacle is removed
F68 – RIO-CELL T2
Second wireless photocell channel; only with RIOCN8WS. P3 is available only with F19.
OFF
P1 – reopen during closing
P2 – close again during opening
P3 – stop, then close automatically
P4 – stop and resume after the obstacle is removed
F71 – Partial Opening Time
Used when F11 is off; sets the opening time for command 2–3P.
5 to 40 s
5 s – factory setting

Users and system U / A / H

Function and descriptionOptions / use
U1 – Add User
Store a remote control or other access device; capacity: 250 users.
1 – open/close
2 – open – STOP – close – STOP
3 – open only
4 – partial opening
U2 – Delete User
Deletes the selected position. After confirmation, CLr is displayed.
Select the stored number and press ENTER.
U3 – Delete All
Deletes all users; this does not reset the drive.
OFF
ON – delete
U4 – Radio Coding
Select the code to be received. Selecting the coding in this older version automatically deletes stored remote controls. TWIN allows multiple users to share the same key.
1 – all supported coding types
2 – Rolling Code
3 – TWIN
A1 – Motor Type
Must match the drive, not the weight set by the user.
1 – BX704AGS
2 – BX708AGS
A3 – Travel Learning
Automatic calibration; only with F11. Without calibration, commands are disabled when the encoder is active.
OFF
ON – start
A4 – Parameter Reset
Restores the factory settings. After resetting, check the configuration and safety inputs.
OFF
ON – execute
A5 – Number of Movements
Displays the number of completed manoeuvres.
OFF
ON – display
H1 – Firmware Version
Displays the control board version.
Display and record for servicing.

Storing Remote Controls

ZBX7N with radio card AF43S 433.92 MHz supports up to 250 users. TOP44RBN uses Rolling Code at 433.92 MHz. The relevant coding must be enabled in menu U4; do not assume that any remote control on the same frequency is compatible.

Insert or remove the AF card only when the power is off. With U4 = 1, all supported codes are enabled; U4 = 2 limits reception to Rolling Code. Before confirming the U4 selection, be aware that the radio memory will be erased: in this older version, selecting the coding automatically deletes stored remote controls. Record the users first and prepare to store them again; matching F8 alone does not confirm how U4 will behave.

  1. Select U1 in the menu and press ENTER.
  2. Select the command: 1 = open/close; 2 = open–STOP–close–STOP; 3 = open only; 4 = partial opening.
  3. Confirm with ENTER. A free user number from 1–250 flashes on the display for a few seconds.
  4. While it is flashing, transmit the code using the desired button on the remote control. Record the stored position; after exiting the menu, test the command.
  5. Repeat U1 to add another function or user. If error E15 appears, check the card, frequency and coding.

Adding a user via U1 and transmitting the code while the position flashes

Deleting one or all users

One user: U2 → ENTER → use the arrows to select the stored number → ENTER. The text CLr confirms deletion. All users: U3 → ENTER → ON → ENTER. U3 is neither the A4 parameter reset nor the A3 calibration.

Resetting Parameters and Transferring Memory

A4 – Factory Parameters

Before resetting, record A1, F54, the safety input settings, automatic closing and access details. Select A4, press ENTER, choose ON, then press ENTER again. Then check all required parameters, the calibration status and safety functions. Do not assume that A4 confirms deletion of all radio users; use U3 to delete them.

F50 / F51 – Memory Roll

  1. Disconnect the power and insert the Memory Roll into the marked socket.
  2. After switching on, select F50 = ON and press ENTER; users and configuration will be saved.
  3. Disconnect the power again before removing the card and inserting it into the other compatible board.
  4. On the target board, select F51 = ON and press ENTER. Check the transferred settings against the specific drive and installation.
  5. After transferring, it is advisable to remove the card, always with the power off.

Two MASTER / SLAVE drives

Into both boards Insert the RSE with the power off and connect A–A, B–B and GND–GND using UTP CAT5. Connect commands and safety devices to the MASTER. On the MASTER, set F49 = 1, the correct F54, and F52 = ON, then confirm the transfer; next, run A3. Store users on the MASTER. The SLAVE programming buttons are disabled in coupled mode.

RSE card and serial connection A, B and GND

A standard open/close command or an open-only command operates both leaves; a partial-opening command opens the MASTER only. Coupling two operators does not increase the weight limit for a single leaf. For standalone CRP communication, use the corresponding F49/F56/F63 settings, not MASTER/SLAVE mode.

RIO wireless safety devices

Connect the RIOCN8WS to the RIO-CONN with the power off. Configure the RIOED8WS safety edges and RIOPH8WS photocells using the corresponding F65–F68 settings and according to their own wiring; RIOLX8WS is for wireless signalling. Without configuration, the control board may display E18; if the connection fails or is disrupted, it may display E17. Do not confuse RIO-CONN with the AF socket for remote controls.

RIO-CONN interface and corresponding wireless devices

Troubleshooting and fault resolution

DisplayMeaningCheck / solution
E1Calibration error.Check the mechanical stops, limit switches, free movement, A1 and F54; then repeat A3.
E2Calibration / encoder setup.First check whether A3 learning was completed successfully, and check F11. E2 alone is not E3 – an encoder fault. If the message remains after successful learning, check the factory encoder wiring and contact service.
E3Encoder fault.With the power off, check the +/E/D connector and wires; have any damage repaired by a service technician. Do not disable the safety feature as a substitute for repair.
E4Safety test error.Compare the actual TS wiring, power supply and photocell contact with F5 and F2/F3.
E7Insufficient operating time.Check resistance along the entire travel, end positions and calibration. Do not increase the force on a gate that is binding.
E8Release hatch open.Lock the mechanism and close the hatch; check that it is being detected.
E9Obstacle while closing.Remove the obstacle; manually check the guide/rack, then F34/F35.
E10Obstacle while opening.Remove the obstacle from the opening path, check the guide and limit switch, then adjust sensitivity.
E11Maximum number of detected obstacles reached.Check for recurring resistance or obstacles along the entire travel and check the encoder; after repair, perform a test.
E15Incompatible remote control.Check the AF card, frequency and U4; do not try to resolve the error by resetting the entire control board.
E17Wireless system error.Check the RIO interface, devices and interference. The system may block movement.
E18Wireless system configuration missing.Check the RIOCN8WS and configure the relevant F65–F68 settings and devices.

If the gate does not move or close

Does not move in either direction: check the power supply, operator lock, hatch, STOP status and safety contacts, remote-control battery, and any command that may be stuck. Opens but does not close: check the photocell beam, alignment, NC contact and CX/CY configuration; do not install a permanent jumper across a connected safety device.

ZBX7N fuses for 230 V

FuseRating / type
LINE – mains5 A-F, fast-acting
BOARD – control board630 mA-F, fast-acting
ACCESSORIES – accessories1 A-F, fast-acting

Disconnect the power supply before checking fuses. Use the same rating and fast-acting type; using a higher-rated fuse or repeatedly replacing it without removing the short circuit is not a repair.

Maintenance and force adjustment

Regularly check that the travel path and rack are clean and move freely, check fastenings and limit switches, inspect cables for damage, and check the release mechanism and operation of every safety device. Disconnect the power supply before cleaning or carrying out any work. Lubricate only mechanical parts that require it; the guide must not create additional friction.

Motor torque is adjusted using the transformer's black Faston terminal in positions 1 to 4: 1 is minimum, 4 maximum. Move the terminal only with the power off, following the original diagram. Encoder sensitivity is adjusted separately using F34/F35; higher torque or lower sensitivity is no substitute for correctly positioning safety edges and testing forces.

The service record should include the date, number of operations A5, version H1, repairs carried out and the result of the safety-device test. When finished, refit the covers without trapping any cables.

BX704AGS technical specifications

The data applies to the specified operator and control version. Before installation, compare the power supply, motor identification and values with the motor rating plate.

ParameterValue
Maximum leaf weight400 kg
Maximum leaf length14 m
Mains power supply230 V AC, 50/60 Hz
Motor power supply230 V AC
Power420 W
Thrust300 N
Travel speed10 m/min
Protection ratingIP44
Operating temperature−20 to +55 °C
Cycles per hour17 with a 4 m reference leaf / 20 °C
Consecutive cycles6 with a 4 m gate leaf / 20 °C
Capacitor12 µF
Standby power consumption2.6 W
Power consumption with Green Power module0.5 W; the module is not a standard battery backup
Motor thermal protection150 °C
Electrical protection classI
Weight of the drive unit only15 kg
Pinionmodule 4
Limit switchesmechanical
Control unitZBX7N with display and encoder

Dimensional drawing of the CAME BX704AGS drive

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about Drive kit for sliding gates up to 400 kg CAME BX704, 801MS-0020 (D)

Product: Drive kit for sliding gates up to 400 kg CAME BX704, 801MS-0020 (D)
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.