CAME BXV10AGS - standalone operator for sliding gates up to 1000 kg (A)


Product availability: within 3 days

We usually dispatch goods within 3 days.


CAME BXV10AGS - standalone operator for sliding gates up to 1000 kg (A) CAME BXV10AGS - standalone operator for sliding gates up to 1000 kg (A)
CAME-BXV10AGS-A
within 3 days
€478.60 excluding VAT
€588.68 including VAT

 pcs
Weight
12 kg

Description of CAME BXV10AGS - standalone operator for sliding gates up to 1000 kg (A)

CAME BXV10AGS gate operator is designed for sliding gates with a weight of up to 1000 kg and a gate leaf length of up to 20 m. It has an electromechanical stop switch. The operator is non-reversible. Detailed technical specifications ». Download the manual ».

CAME BXV10AGS with ZN7 control board is an operator for a sliding gate leaf up to 1,000 kg and 20 m long. The mains supply is 230 V AC, and the motor is 24 V DC; the limit switches are mechanical. Consider the gate’s dimensions, weight, and resistance together.

Disconnect the mains and any batteries before working on the system. Check the fixed stops, protection of hazardous areas, safety functions, and operating forces of the completed gate.

Before installation, check the nameplate, ZN7, H1 version, and menu. The technical specifications below apply to the described configuration with F28 = 60–100%, F8 = 1/2, and U3 = 0/1. These three items alone do not identify the full firmware version. If the markings or connectors differ, use the relevant manual.

Quick navigation
Operator only Accessories
Installation Wiring
Manual release Control board overview
Terminals and power supply Photocells and testing
Initial startup Travel learning
Programming Remote controls
Reset and memory Troubleshooting
Maintenance Technical specifications
Installation PDF manual

CAME BXV10AGS operator only

This manual covers the CAME BXV10AGS operator only (A). For the package with accessories, see the CAME BXV10AGS kit.

The maximum length of 20 m refers to the gate leaf; it is not necessarily the clear opening width. Selecting A1 does not increase the actual operator’s load capacity.

Accessories and wiring examples

The devices below are specific examples for the wiring configurations shown. Check the contents of the operator-only package and confirm which accessories are actually included in the specific offer; if using a different model, refer to its own manual.

Component Example / application
Photocells CAME DIR10, 12/24 V AC/DC; range 10 m, terminals and test.
Flashing light CAME KLED24, 24 V AC/DC, 2 W; wiring 10–E.
Radio receiver CAME AF43S and TOP-432EE, example of fixed code at 433.92 MHz; check code compatibility against the control board settings.
Rack Gear racks, module 4 for this model.
Controls Switches, push buttons, and readers; volt-free NO commands and NC STOP input, as specified by the control board.

Installing the operator

With the operator released, the gate must move easily along its entire travel, with no slope, damaged wheels, or risk of coming off the guide. Check that fixed mechanical stops are fitted in both the open and closed positions, that the base is stable, and that areas where the gate leaf could trap someone are protected. There must be no standing water in the operator area, and the operator must not be exposed to a direct jet of water. If the sliding gate leaf has a built-in pedestrian gate, powered movement must only be possible when it is securely closed.

Foundation and anchor plate

The installation example uses an excavation 400 × 240 mm and 800 mm deep. Size the foundation to suit the ground conditions and the specific gate. The formwork extends 50 mm above ground level; use reinforcement and M12 anchors. A Ø 40 mm conduit is recommended for the operator power supply, Ø 25 mm for accessories, and Ø 20 mm for a possible release cable.

Example of a foundation and conduit routing for BXV
Example of a foundation and conduit routing for BXV
Formwork 50 mm above ground level and reinforcement for the concrete foundation
Formwork 50 mm above ground level and reinforcement for the concrete foundation

Set the anchor plate level, route the cables through its openings, and leave the threaded parts of the anchors protruding above the surface. Allow the concrete to cure for at least 24 hours. Position the plate in relation to the rack as shown: the 95 mm horizontal offset and 106 mm height refer to the marked surfaces in the cross-section. Do not confuse these with the foundation dimensions.

Anchor plate, holes, and M12 fixings
Anchor plate, holes, and M12 fixings
Position of the anchor plate relative to the BXV rack
Position of the anchor plate relative to the BXV rack

Installing the operator and adjusting its height

Remove the cover and place the operator on the plate. The cables must pass underneath the housing and through correctly fitted cable glands. While adjusting, raise the operator using the threaded feet by 5–10 mm, leaving room to adjust the meshing.

Mounting the BXV operator on the plate
Mounting the BXV operator on the plate
Cable gland and height adjustment for the BXV operator
Cable gland and height adjustment for the BXV operator

Rack and gear mesh clearance

Release the operator and attach the rack while moving the gate leaf by hand. When joining rack sections, place a spare rack section under the joint so the teeth align smoothly. After installation, adjust the operator’s vertical and horizontal position.

Installing the BXV gear rack
Installing the BXV gear rack

Leave 1–2 mm of clearance between the rack and pinion. The gate’s weight must not rest on the operator. Move the gate through its entire travel by hand, check the gear mesh and rack joints, and only then tighten the nuts and washers on the anchors.

1–2 mm clearance and BXV gear mesh adjustment
1–2 mm clearance and BXV gear mesh adjustment

Mechanical limit switches

Move the gate leaf by hand to the open position. Fix the opening limit cam to the rack so that its ramp reliably actuates the spring-loaded microswitch. Set the closing limit cam in the same way. Secure the cams firmly; the gate’s fixed mechanical stop and the operator’s limit cam serve different purposes.

In the assembly shown, leave approximately 20 mm before the fixed stop. Check the stopping distance at the actual speed and under load.

Mechanical limit cam at the opening end
Mechanical limit cam at the opening end
Mechanical limit cam at the closing end
Mechanical limit cam at the closing end

Wiring

Connection Cable / requirement
230 V AC mains, L/N/PE 3G × 1.5 mm² up to 20 m; 3G × 2.5 mm² for 20–30 m.
Controls Number of conductors according to the control setup; 0.5 mm² cross-section for the short runs listed.
DIR10 photocells TX: 2 × 0.5 mm²; RX: 4 × 0.5 mm². Ensure the TX connection and NC contact are connected.
Antenna RG58, maximum 10 m; 5 m or less recommended.
RSE / CRP UTP CAT 5; separate serial connection, not for motor power.

The number of conductors must accommodate the entire selected wiring diagram. For longer runs, simultaneous loads or other accessories, recalculate the cross-section based on current and voltage drop. Protect cables from damage and contact with the motor or transformer; route the mains supply and low-voltage circuits with suitable separation.

Manual release during a power failure

Disconnect the power supply and secure the gate leaf before moving it manually. Releasing a damaged or unbalanced gate may cause uncontrolled movement.

  1. Insert the key into the lock and turn it in the direction of the arrow shown in the image.
  2. Pull and open the release lever as shown in the image.
  3. Move the gate manually in a controlled manner, keeping people clear of its path.
  4. To re-engage the mechanism, return the lever to its original position and lock the mechanism. Before operating the motor, check that the drive is engaged.
Manual release and re-engagement of BXV
Manual release and re-engagement of BXV

Guide to the ZN7 control board

The ZN7 has a display and ESC, arrow and ENTER buttons. Settings, timings and users are managed through the menu. The AF, Memory Roll, R700/R800, RSE and RIOCN8WS connectors have specific functions; insert or remove the card only when both the mains and batteries are disconnected.

Display, terminals and connectors on the ZN7 control board
Display, terminals and connectors on the ZN7 control board

Figure number Component
1 / 2 / 3 Motor / encoder / limit switches
4 / 5 / 6 Commands and safety / antenna / AF
7 / 8 / 9 / 10 Memory Roll / R700 or R800 / RSE / RIOCN8WS
11 / 12 Display / programming buttons
13 / 14 / 15 A–B–GND serial connection / A–B keypad / S1–GND transponder
16 / 17 / 18 GSM module / RGP1 / accessories and lights
19 / 20 / 21 / 22 Accessory fuse / board input / mains fuse / mains supply

ZN7 terminals and power supply

Terminals Use / voltage / polarity
L / N / PE 230 V AC mains, 50/60 Hz for BXV10AGS. PE is the protective conductor; AC has no +/− polarity.
10 / 11 Accessories: typically 24 V AC, with battery operation 24 V DC, total load no more than 40 W. For DC 10 = positive (+), 11 = negative (−); no polarity for AC.
10 / E Flashing light or courtesy light, 24 V AC/DC, max. 25 W. For DC, 10 is the positive common terminal and E is the switched output.
10 / 5 Gate status indicator, 24 V AC/DC, max. 3 W. For DC, 10 is the positive common terminal and 5 is the switched output; not for continuous power supply.
24 / 0 Internal supply to the board from the power supply section; do not use as an accessory output or as an external battery input.
M / N 24 V DC motor; retain the wiring for the correct assembly. Not a 230 V supply.
+ / E / − Encoder: +/− power supply and E signal; not a universal accessory output.
F / FA, F / FC F common, FA open, FC closed; NC limit contacts, no polarity.
A / B / GND – RSE Serial interface with RSE card; do not confuse with the A/B keypad connection.

ZN7 accessory power output, 10 (+) and 11 (−) for DC
ZN7 accessory power output, 10 (+) and 11 (−) for DC

Commands and safety contacts

Terminals Contact / function
1–2 NC STOP; set F1 = ON if connected. Factory setting: F1 = OFF. No polarity.
2–7 NO command; function selected by F7. Voltage-free contact, no polarity.
2–3P NO partial or full opening, depending on F8. Voltage-free contact, no polarity.
2–CX / 2–CY NC safety inputs; configure F2/F3. No polarity.
10 / TS Tested photocell supply circuit as shown in the wiring diagram; do not enable F5 unless wired correctly.
A–B / R800 Code keypad with R800 decoding card, F14 = 1.
S1–GND / R700 Transponder or reader with R700, F14 = 0.
Antenna / AF RG58 and plug-in radio card with the correct frequency/coding.

STOP, commands, reader and keypad on ZN7
STOP, commands, reader and keypad on ZN7

Flashing light and status indicator

KLED24, 24 V AC/DC and 2 W, connect to 10–E; for a flashing light, set F18 = 0. KLED24 does not have a separate +/− marked supply input. For AC, there is no DC polarity; for DC, 10 is the board's positive common terminal. Do not connect a 230 V flashing light to this 24 V output.

Output 10–5 is for a low-power status indicator, max. 3 W, with setting F10. Courtesy-light mode F18 = 1 requires an automatic closing time; the light remains on from opening until the gate is fully closed, including during the pause.

Light, flashing light and status indicator on ZN7
Light, beacon and status indication on the ZN7
Wiring the CAME KLED24 24 V beacon
Wiring the CAME KLED24 24 V beacon

Photocells and safety test

CAME DIR10 consists of a TX transmitter and an RX receiver with a 10 m range. Set the receiver jumper to 24 V. The pair draws 60 mA at 24 V AC. The RX power supply is marked 10 (+), 2 (−); the TX terminals are marked TX and 2; the manufacturer does not show separate +/− markings for them in this diagram. With AC power, DC polarity does not apply. The TX output is part of the synchronisation circuit; connect RX TX to TX TX as shown in the diagram, not directly to board terminal 10.

CAME DIR10 photocell TX and RX terminals
CAME DIR10 photocell TX and RX terminals
DIR10 jumper for 12 or 24 V power supply
DIR10 jumper for 12 or 24 V power supply

Photocell terminal Standard wiring Wiring with test
RX 10 (+) Board 10 Board 10
RX 2 (−) and RX C Board 2 Board 2
RX TX ↔ TX TX Connect TX between the receiver and transmitter Same connection
TX 2 Board 2 Board TS
RX NC Board CX Board CX

The C–NC contact is a volt-free safety contact. It has no positive or negative polarity. The power supply wiring and the contact are two separate circuits. With DC, terminal 10 is positive; the RX 2 negative output is connected to the board’s common terminal 2 in this particular diagram. Do not confuse terminal 2 with power supply terminal 11.

For a contact on CX, set F2 = C1. For a contact on CY, select the corresponding response via F3. C1 reopens during closing; C2 recloses during opening; C3 stops and then closes automatically, and requires F19; C4 waits until the obstruction is removed, then resumes movement.

Standard wiring for synchronised photocells on the ZN7
Standard wiring for synchronised photocells on the ZN7

Test wiring via TS

For the test, TX 2 is moved to TS, while RX 2 and RX C remain connected to board terminal 2. The TX connection between the transmitter and receiver remains in place. First change the wiring with the power off, and only then enable the test.

Set F5 = 1 for CX, 2 for CY, or 4 for both CX and CY. If the test fails, E4 is displayed and the drive will not execute the command. This function is used with active safety inputs.

Wiring synchronised photocells with the TS test on the ZN7
Wiring synchronised photocells with the TS test on the ZN7

After wiring, test by interrupting the beam during the relevant movement, then clearing the beam again. Do not bypass the safety input as a permanent fault remedy.

Safety edges

Connect an NC contact edge between 2 and CX or CY, and select C7 – reopening during closing, or C8 – reclosing during opening. A volt-free contact has no polarity. Do not connect a resistive edge as a standard NC contact; it requires an interface suitable for the specific control unit.

First start-up of the ZN7

  1. Check that the gate moves freely, the rack is correctly fitted, the fixed and limit stops are secure, the drive is engaged, the wiring is correct, and hazardous areas are protected.
  2. Switch on the power and check the display. Set A1 = 4 for a motor rated up to 1000 kg, F54 according to the direction and F1 according to the connected STOP input.
  3. Set F2/F3 for the connected safety devices and, if applicable, test F5. Leave unused inputs disabled. For learning, F11 must be set to ON.
  4. Run A3 – travel learning.
  5. Set the operating parameters and users, then test the full cycle, partial opening, each safety device, the beacon, and behaviour after a power failure.

The first normal manoeuvre after switching on the power is opening; wait for it to finish. A3 calibration has its own sequence. If you notice unusual noise, vibration or incorrect direction, stop the drive immediately using ESC/STOP and rectify the cause.

A3 – automatic travel learning

Prerequisites: Correct A1 and F54 settings, STOP configured, encoder active, limit switches and fixed stops correctly set. Manually move the gate leaf approximately halfway, then re-engage the drive. The area must remain clear.

During calibration, the safety devices are disabled, except for stopping with the ESC button. Supervise the entire movement and keep people out of the travel path.

  1. Press ENTER, use the arrow keys to select A3, then press ENTER to confirm.
  2. Select ON and press ENTER to confirm.
  3. The drive first closes to the end position; the display shows CL1.
  4. It then opens to the end position; the display shows OP1.
  5. When complete, check the full movement and safety devices. For E1/E2, first rectify the cause as described in Diagnostics; do not repeat the learning procedure while a mechanical fault remains.
ZN7 calibration – closing CL1 and opening OP1
ZN7 calibration – closing CL1 and opening OP1

Programming via the display

Program the drive while it is stopped. ENTER opens the menu and confirms a selection; arrows </> select an item or change a value. After making a change, press ENTER to confirm. ESC cancels an unconfirmed change, goes back, or exits the menu. During normal operation, ESC stops the drive; the arrow keys allow test movement.

ESC, arrow and ENTER buttons on the ZN7
ESC, arrow and ENTER buttons on the ZN7

Factory values for the listed menu are explicitly shown in bold. Accessory functions appear only when the required card is installed or the related function is active. Write down the current settings before making changes. A lower sensitivity value for F34/F35 means higher sensitivity; after changing speed, torque or sensitivity, check the forces and safety devices.

Functions F

Function and description Values / factory setting
F1 – Full stop
NC input 1–2. STOP disables automatic closing; resume with a new command. If no STOP is connected, leave set to OFF.
OFF
ON
F2 – CX input
Contact 2–CX; select according to the photocell or safety edge. C3 requires F19.
OFF – disabled
C1 – reopen while closing
C2 – reclose while opening
C3 – stop, then close automatically
C4 – wait for the obstacle to be removed, then continue
C7 – safety edge: reopen while closing
C8 – safety edge: reclose while opening
F3 – CY input
Contact 2–CY; second independent safety input. C3 requires F19.
OFF – disabled
C1 – reopen while closing
C2 – reclose while opening
C3 – stop, then close automatically
C4 – wait for the obstacle to be removed, then continue
C7 – safety edge: reopen while closing
C8 – safety edge: reclose while opening
F5 – Photocell test
Requires the tested circuit to be wired through TS. The test is always active for wireless devices.
0 – disabled
1 – CX
2 – CY
4 – CX and CY
F6 – Hold-to-run control
The operator stops when the button is released; all other control devices are disabled. Use only for supervised control; verify each button’s direction by testing.
0 – disabled
1 – enabled
F7 – Command 2–7
Assigns an action to the wired command.
0 – step-by-step: open – close
1 – open – STOP – close – STOP
2 – open only
3 – close only
F8 – Command 2–3P
With the encoder enabled, partial opening is set by F36; with it disabled, by F71.
1 – partially open
2 – fully open
F9 – Obstacle detection when the motor is stopped
When the gate is open, closed, or fully stopped, movement is prevented if the safety device detects an obstacle.
OFF
ON
F10 – Gate status indicator
Output 10–5, 24 V AC/DC, max. 3 W.
0 – on when the gate is open and while it is moving
1 – flashes every 0.5 s while opening and every 1 s while closing; open = on, closed = off
F11 – Encoder
Controls deceleration, obstacle detection, and sensitivity.
ON – enabled
OFF
F12 – Soft start
Movement at a slow speed for the first few seconds after a command.
OFF
ON
F14 – Sensor type
Access device with the corresponding decoding card.
0 – transponder / card reader with R700
1 – keypad with R800
F18 – Light 10–E
Output 24 V AC/DC, max. 25 W. The cycle light requires automatic closing to be set.
0 – warning light during movement
1 – cycle lighting from opening until fully closed, including during the waiting time
F19 – Automatic closing
Waiting time after fully opening. Not activated after a full STOP, a power failure, or activation of the obstacle-detection safety device.
OFF – disabled
1 to 180 s
F20 – Closing after partial opening
Requires F19 to be enabled; the same restrictions apply for STOP, power failure, and obstacle detection.
OFF
1 to 180 s
10 s – factory setting
F21 – Pre-flashing
Warning-light time before movement.
OFF
1 to 10 s
F28 – Opening speed
Percentage of maximum opening speed; after changing the setting, check the full movement cycle and safety.
60 to 100%
100% – factory setting
F30 – Deceleration speed
Deceleration during opening and closing; only with the encoder enabled.
10 to 50%
50% – factory setting
F34 – Travel sensitivity
Obstacle detection during normal movement. A lower value means higher sensitivity.
10 to 100%
10% – highest sensitivity
100% – lowest sensitivity
F35 – Deceleration sensitivity
Only with the encoder enabled; check the forces after changing the setting.
10 to 100%
10% – highest sensitivity
100% – lowest sensitivity
F36 – Partial opening point
Percentage of total travel; only with the encoder enabled.
10 to 80%
10% – factory setting
F37 – Opening deceleration point
Start of deceleration as a percentage of total travel; only with the encoder.
10 to 60%
25% – factory setting
F38 – Closing deceleration point
Start of deceleration as a percentage of total travel; only with the encoder.
10 to 60%
25% – factory setting
F49 – RSE serial interface
Requires a card in the RSE connector.
0 – disabled
1 – paired operators
3 – CRP communication
F50 – Save data
Users, times, and configuration to Memory Roll; this function appears only when memory is inserted.
0 – do not execute
1 – save
F51 – Load data
Loading saved data from Memory Roll; this function is displayed only when a memory device is inserted.
0 – do not perform
1 – load
F52 – MASTER → SLAVE transfer
Transfers parameters to the second drive; only for a paired RSE.
OFF
ON – transfer
F54 – Opening direction
Select according to the actual installation.
0 – left
1 – right
F56 – CRP address
Unique board address when multiple drives are connected to CRP.
1 to 255
F63 – Serial communication speed
Set to match the connected system.
0 – 1,200 bps
1 – 2,400 bps
2 – 4,800 bps
3 – 9,600 bps
4 – 14,400 bps
5 – 19,200 bps
6 – 38,400 bps
7 – 57,600 bps
8 – 115,200 bps
F65 – RIO ED T1
First wireless safety edge; only with the appropriate RIO interface.
OFF
P0 – STOP, no automatic closing; resume with a new command
P7 – reopen during closing
P8 – reclose during opening
F66 – RIO ED T2
Second wireless safety edge; check channel T2 and this item on the display.
OFF
P0 – STOP, no automatic closing; resume with a new command
P7 – reopen during closing
P8 – reclose during opening
F67 – RIO PH T1
First wireless photocells; only with a RIO interface. P3 requires automatic closing.
OFF
P1 – reopen during closing
P2 – reclose during opening
P3 – partial stop with automatic closing
P4 – wait for the obstacle to be removed
F68 – RIO PH T2
Second wireless photocells; only with a RIO interface. P3 requires automatic closing.
OFF
P1 – reopen during closing
P2 – reclose during opening
P3 – partial stop with automatic closing
P4 – wait for the obstacle to be removed
F71 – Partial opening time
Used when encoder F11 is disabled; when the encoder is active, set F36.
5 to 40 s

Users and system U / A / H

Function and meaning Options / confirmation
U1 – Add a user
Pair a remote control/access device; up to 250 users.
1 – step-by-step
2 – sequential
3 – open only
4 – partial opening
U2 – Delete one user
Select the stored user number with the arrow buttons or activate the corresponding remote control; ENTER confirms, and CLr indicates deletion.
OFF
ON – select and delete a user
U3 – Delete all users
Deletes all stored users.
0 – do not perform
1 – delete
U4 – Radio coding
Selecting 2 or 3 removes stored transmitters using a different coding. Record the users and check the control unit version before confirming.
1 – all supported coding types
2 – Rolling Code
3 – TWIN / TW key block
A1 – Motor type
For BXV10AGS, the value must be 4. Another option does not change the physical motor's load capacity.
1 – 400 kg
2 – 600 kg
3 – 800 kg
4 – 1,000 kg
A3 – Travel path learning
Starts automatic calibration.
OFF
ON – start
A4 – Reset parameters
Restores factory settings and deletes the learned travel path. Reconfigure and verify safety before operation.
OFF
ON – execute
A5 – Operation counter
Displays the number of individual movements; this is not the number of complete opening/closing cycles.
001 = 100 operations
010 = 1,000
100 = 10,000
999 = 99,900
CSI = service intervention
A6 – Motor torque
Set according to the mechanism; after changing the setting, measure the forces and check the safety protection.
1 – minimum to 5 – maximum
H1 – Firmware version
Displays the FW and GUI versions; record them for servicing and to verify the control unit version.
Display version

Pairing and deleting remote controls

ZN7 memory has a capacity of 250 users. The receiver must be installed in the AF slot and match the transmitter's frequency and coding. An example of a 433.92 MHz fixed-code transmitter is TOP-432EE with AF43S. U4 can restrict the range of accepted coding types; matching frequencies alone are not sufficient.

  1. In U1, select the operation: 1 step-by-step, 2 sequential, 3 open only, or 4 partial opening.
  2. Confirm with ENTER, then send the code by pressing the selected button on the remote control.
  3. Repeat the procedure for each additional user. Record the stored user numbers and assigned commands, then test the actual operation.

To delete a single user, use U2: select ON, choose the number with the arrow buttons or activate the corresponding stored transmitter, then confirm with ENTER. CLr on the display confirms deletion. U3 = 1 deletes all users.

U4 = 2 (Rolling Code) or 3 (TWIN) deletes previously stored transmitters with a different coding. Before making a change, check the system, H1 version, and remote control records; do not use this setting to troubleshoot a receiver fault experimentally.

Backup via Memory Roll

  1. Disconnect the mains power and any batteries, then insert the Memory Roll into its connector.
  2. Switch on the power; use F50 = 1 to save the data and F51 = 1 to load it. Loading replaces the board’s data with the saved data.
  3. When finished, disconnect the power again and remove the memory card.
  4. After loading, check the model, direction, safety devices, and all commands. This ZN7 has a Memory Roll connector; do not use a nonexistent USB port.

Pairing two operators

Use an RSE card in each board and connect them using CAT 5 via A–B–GND as shown. Connect the control and safety devices to the MASTER board. On that board, set F49 = 1, the direction using F54, and parameter transfer using F52. Store users on the MASTER; partial opening and the step-by-step command operate as shown for the combined system.

RSE and MASTER–SLAVE connection for two BXV operators
RSE and MASTER–SLAVE connection for two BXV operators

RIO wireless safety system

RIOCN8WS uses a dedicated RIO connector. F65/F66 configure two wireless safety edges, and F67/F68 configure two photocell channels. Check the actual device and channel labels on the display. The wireless safety test remains active; resolve communication loss E17 or missing configuration E18 before resuming operation.

A4 – parameter reset

Before resetting, note down the H1 version, settings, and users; if you have a Memory Roll, save the data. Select ON in A4 and confirm with ENTER. For the version described here, the factory settings are restored and the travel path learning is erased.

After resetting, set A1, F54, F1, and the safety inputs again, then perform A3 learning. Check the safety devices before normal operation. Deleting users is a separate function, U3. On a board with a different menu, A4 may restore a different range of settings; follow the instructions for that specific version.

Display-based diagnostics

Code Meaning / check
E1 Calibration error. Check A3, the mechanism, direction, and limit switches.
E2 Configuration error. Check model A1, direction F54, and that learning is complete.
E3 Encoder error. With the power off, check the +/E/− connector and wiring; after repair, perform learning.
E4 Safety test error. Check TX on TS, power supply, NC, and F5.
E7 Operating time exceeded. Check for resistance, the end stops, and whether the movement completes.
E9 Obstacle while closing. Remove the actual obstacle; check the rack and sensitivity.
E10 Obstacle while opening. Check the travel path and correct force settings.
E11 Too many consecutive obstacles. Repair the mechanism or the cause of the safety device activation.
E13 Both limit contacts are open. Check FA/FC/F and the switching end stops.
E14 Serial communication error. Check RSE, CAT 5, and configuration.
E15 Incompatible transmitter. Check AF, frequency, and U4.
E17 Wireless system communication fault. Check RIO, devices, and interference.
E18 Wireless system is not configured. Check RIO and the relevant F65–F68 settings.

If the gate does not move, check the power supply, operator lock, STOP input and active safety inputs, any button that is stuck on, and the transmitter battery. If it opens but does not close, check the photocells and their NC contact. Do not bypass a safety device fault with a permanent jumper.

ZN7 fuses for 230 V

Circuit Fast-acting fuse
Mains LINE 1.6 A-F
Accessories 2 A-F

Check fuses with the mains and batteries disconnected. Replace only with a fuse of the same rating and type; first eliminate the cause of the short circuit or overload.

Maintenance and servicing

Regularly check that the travel path and rack are clean, that the gate moves freely by hand, and that the operator, switching end stops, cables, manual release, and all safety devices are secure and working properly. Disconnect the mains and battery backup before cleaning or carrying out any work. If there is damage, unusual noise, or vibration, stop operation and identify the cause.

Set torque A6 and sensitivity F34/F35 according to the actual mechanism; do not mask resistance or a fault by increasing the torque. After adjustment or servicing, check the full movement, forces, and safety devices. Record H1, the number of manoeuvres A5, and any repairs. Provide the user with the manuals for the complete system and demonstrate the manual release. Take electronic components and batteries to a designated collection point when disposing of them.

CAME BXV10AGS technical specifications

Parameter Value
Maximum gate leaf weight 1000 kg
Maximum gate leaf length 20 m
Operator power supply – mains 230 V AC, 50/60 Hz
Motor power supply 24 V DC
Power 400 W
Thrust 1000 N
Maximum travel speed 11 m/min
Maximum current – value from the manufacturer's technical table 16 A
Protection – ingress protection rating IP54
Operating temperature −20 to +55 °C
Duty Intensive duty; this is not a fixed number of cycles per hour.
Operating time 180 s
Standby power consumption 5.5 W
Protection class I
Pinion / limit switches Module 4 / mechanical
Cover colour Grey RAL 7024
Controls in this manual ZN7, display and ESC/arrows/ENTER
Setting A1 4 – 1000 kg
Body dimensions (width × depth × height) 290 × 212 × 363 mm
Anchor plate 300 × 170 mm; spacing as shown in the drawing

Dimensional drawing of the CAME BXV10AGS drive
Dimensional drawing of the CAME BXV10AGS drive

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about CAME BXV10AGS - standalone operator for sliding gates up to 1000 kg (A)

Product: CAME BXV10AGS - standalone operator for sliding gates up to 1000 kg (A)
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.