CAME BKV20AGS – standalone operator for sliding gates up to 2000 kg (A)
| Product availability: | within 3 days | We usually dispatch goods within 3 days. |
|---|
within 3 days
€981.68 including VAT
| Weight |
|---|
| 12 kg |
Description of CAME BKV20AGS – standalone operator for sliding gates up to 2000 kg (A)
CAME BKV20AGS operator is designed for sliding gates weighing up to 2000 kg and gate leaf length up to 20 m. It has an electromechanical stop switch. The operator is non-reversible. Detailed technical specifications ». Download the manual ».
CAME BKV20AGS, code 801MS-0310, is a drive for a large sliding gate leaf up to 2,000 kg and 20 m long. It has a 36 V DC motor, a graphic display, four wired safety inputs and mechanical limit switches. The mains supply is 230 V AC. Assess the gate's capacity, length and actual resistance together.
Disconnect the mains and any batteries before opening the unit or inserting cards. Check the BKV20AGS label, the ZN8 control board and the FW/GUI version in the Information menu. The settings below are for the graphic menu with Motor type BKV2000 selected. For a different model or menu, refer to its specific manual.
Standalone BKV20AGS drive and related kits
| Version | Selection |
|---|---|
| CAME BKV20AGS standalone drive (A) | A drive for adding to or replacing an assembly; accessories are selected separately. |
| CAME BKV20AGS kit (D) | Alternative kit option. Check the product page for the specific kit to confirm its contents. |
20 m is the maximum gate-leaf length; do not confuse it with the clear opening width. The BKV20AGS uses mechanical limit switches. Magnetic limit switches and the clock card included with AGE versions are not standard equipment on the AGS.
Accessories and wiring examples
The following devices are examples of accessories and their wiring, not items included with the standalone drive. For a different type, use its own manual.
| Component | Example / use |
|---|---|
| Photocells | CAME DIR10, 12/24 V AC/DC; range 10 m, terminals and testing. |
| Flashing light | CAME KLED24, 24 V AC/DC, 2 W; 10–E wiring. |
| Radio receiver | CAME AF43S and TOP-432EE, an example of fixed-code 433.92 MHz; check code compatibility against the control board settings. |
| Rack | Gear racks, module 4 for this model. |
| Controls | Switches, push buttons and readers; volt-free NO commands and NC STOP according to the control board. |
Installing the BKV20AGS
Before installation, check that the gate moves easily and smoothly by hand along its entire travel. The gate and guide must be stable, level and secured against derailment. Check that there are solid stops at both the open and closed positions, and protect against crushing, trapping and rack engagement hazards. Mount the drive on a solid surface, away from direct water exposure. If the gate leaf has a pedestrian gate, movement may be enabled only when it is safely secured.
Foundation and anchor plate
The manufacturer's example specifies an excavation measuring 500 × 280 mm, 800 mm deep and Ø 40 mm conduits. Adapt the foundation dimensions to the ground conditions and the specific gate; this is an installation example, not a universal foundation design. The formwork extends 50 mm above ground and contains steel reinforcement.
Insert the supplied M12 bolts into the plate and secure them with nuts. Bend the preformed anchor tabs and place the plate in the reinforcement. The conduits must pass through its openings. Level the plate precisely; the threaded ends must remain above the concrete. The position relative to the rack is based on the dimensions 76 and 96 mm shown in the cross-section. Allow the concrete to cure for at least 24 hours.
Positioning and height adjustment
After removing the formwork, backfill around the foundation. Remove the anchor nuts and pull the cables approximately 600 mm above the plate. Remove the cover and position the drive; the cables pass through its underside and sealed cable glands. Raise the drive using the threaded feet by 5–10 mm, leaving room to adjust the meshing.
Rack and 1–2 mm clearance
Disengage the drive and fasten the module 4 rack while moving the gate by hand. When joining sections, place a spare rack section under the joint and use two clamps so the teeth align smoothly. Once fastened, adjust the height using the feet and the horizontal position using the slotted holes.
Leave 1–2 mm clearance between the pinion and the rack. The gate's weight must not rest on the drive. Move the gate manually through its full travel, and only after adjustment secure the drive to the plate with washers and nuts.
AGS mechanical limit switches
Open the gate manually. Place the opening limit switch stop on the rack so that its ramp actuates the spring-loaded microswitch, and secure it with the screws supplied. Repeat the same procedure for closing. In the configuration shown, approximately 20 mm is left before the fixed stop; check the run-on distance under the actual load. The fixed gate stop and the drive limit switch stop serve different purposes.
Wiring
| Circuit | Cross-section / condition |
|---|---|
| 230 V AC mains | 3G × 1.5 mm² up to 20 m; 3G × 2.5 mm² for 20–30 m. |
| 24 V warning light | 2 × 1 mm² for the specified cable runs up to 30 m. |
| Photocells | TX 2 × 0.5 mm²; RX 4 × 0.5 mm² as shown in the full wiring diagram. |
| Control devices | Number of cores according to the device; 0.5 mm² cross-section for the specified cable runs. |
| Antenna | RG58, max. 5 m. |
| RSE / CRP | UTP CAT 5, max. 1,000 m, subject to the requirements of the serial system. |
For longer cable runs or multiple loads, recalculate the cross-section based on current and voltage drop. Route the mains supply cable through its own cable gland, separately from the low-voltage circuits. Cables must not touch heated parts or be exposed to mechanical damage.
Manual release and re-engagement
First disconnect the power supply and secure the gate leaf against uncontrolled movement. Do not release a damaged or unbalanced gate unless it has been secured.
- Insert the key into the lock and turn it as shown in the top pair of illustrations.
- Open the release lever outwards from the housing, in the direction of the arrow.
- Move the gate manually and in a controlled manner, keeping people clear of its path.
- To re-engage the mechanism, return the lever to its original position and lock it as shown in the bottom pair of illustrations.
- Before operating the motor, check that the mechanism is locked again.
Orientation on the ZN8 control board
In the following illustration, the board is oriented with the large capacitors at the top, the long terminal blocks at the bottom and the programming buttons on the right. The graphic display and ESC/arrow/ENTER buttons are used for settings, diagnostics and user management. Insert and remove cards only when the mains and any batteries are disconnected.
| Illustration number | Component |
|---|---|
| 1 / 2 / 3 | Motor / encoder / RGP1 or LBB. |
| 4 / 5 / 6 / 7 | Programming buttons / RSE / CAME KEY / AF. |
| 8 / 9 / 10 / 11 | Antenna / safety devices / serial connection / wired commands. |
| 12 / 13 / 14 / 15 | Keypad / transponder / lights / B1–B2. |
| 16 / 17 / 18 / 19 | R700 or R800 / RIOCN8WS / clock card / limit switches. |
| 20 / 21 / 22 / 23 / 24 | Accessory fuse / control board fuse / transformer / Memory Roll / display. |
| 25 / 26 | Mains fuse / mains supply connection on the drive. |
BKV20AGS power supply and terminals
| Circuit / terminals | Voltage, polarity and limit |
|---|---|
| L / N / PE | Mains 230 V AC, 50/60 Hz. L is live, N is neutral and PE is protective earth. AC has no positive or negative polarity. |
| Motor / control board internal power supply | Motor 36 V DC, control board according to the technical table 26 V DC. These are internal circuits in the correct configuration, not an output for accessories. Keep the prescribed wiring; do not connect the mains or an external power supply to them by guesswork. |
| 10 / 11 | Accessories 24 V AC/DC, total max. 20 W; normally 24 V AC. For DC 10 = positive (+), 11 = negative (−); no fixed polarity for AC. |
| 10 / E | Warning light 24 V AC/DC, max. 3 W. For DC, terminal 10 is positive common and E is the switched output. |
| 10 / E3 | Auxiliary light 24 V AC/DC, max. 12 W; set the mode under Manage lights → Light E3. For DC, terminal 10 is positive common and E3 is the switched output. |
| 10 / 5 | Status indication 24 V AC/DC, max. 3 W. For DC, terminal 10 is positive common and 5 is the switched output. |
| B1 / B2 | A separate controlled contact with monostable or bistable mode. It does not supply power to accessories via terminals 10/11. |
| 10 / TS / 2 | Power supply and tested photocell circuit, and common terminal, as specified in the wiring diagram for the particular configuration; TS is not a universal permanent negative output. |
Commands, STOP, safety devices and antenna
| Terminals | Function / contact |
|---|---|
| 1–2 | NC STOP. Stops the gate and disables automatic closing; a new command is required to move it again. If STOP is not used, disable Total stop. |
| 2–3 | NO command to open only. |
| 2–3P | NO partial-opening command. |
| 2–4 | NO command to close only. |
| 2–7 | NO step-by-step or sequential command via Command 2-7. |
| 2–CX / CY / CZ / CK | Four independently configurable safety inputs. Disable unused inputs; configure used ones according to the protective device. |
| S1 / GND | Transponder or reader with the corresponding R700 card. |
| A / B on readers | Code keypad with R800; do not confuse these with the same letters used for the serial connection. |
| A / B / GND on RSE | Pair’s serial connection or CRP, depending on the connector used. |
| Antenna / AF | Connect the RG58 core to the antenna signal and the shield to the marked ground terminal as shown; plug the radio card into AF. |
NO/NC commands and safety contacts are voltage-free and have no +/− polarity. The accessory power supply and its output contact are separate circuits. Do not connect 230 V to the command terminals.
Flashing light and auxiliary light
CAME KLED24 is rated for 24 V AC/DC and 2 W, so connect it to 10–E within the 3 W limit. Its input is not separately marked +/−; polarity does not matter with AC, while with DC, 10 is the board’s positive common terminal. Do not connect a 230 V version of the flashing light here. E3 is a separate light output rated for 12 W; do not confuse E and E3.
DIR10 photocells and testing via TS
The example uses CAME DIR10: TX/RX pair, 10 m range, 12/24 V AC/DC power supply. Set the RX jumper to 24 V. The pair draws 60 mA at 24 V AC. RX has terminals 10 (+), 2 (−), TX, C and NC. TX has terminals TX and 2, with no separate +/− markings in the original diagram. With AC, DC polarity does not apply.
| DIR10 terminal | Standard | With test |
|---|---|---|
| RX10 (+) | Board 10 | Board 10 |
| RX2 (−) and RX C | Board 2 | Board 2 |
| RX TX ↔ TX TX | Connect between RX and TX | Same connection |
| TX2 | Board 2 | Board TS |
| RX NC | Board CX | Board CX |
The C–NC contact has no polarity. In this synchronized diagram, RX2 and C connect to board terminal 2, not 11. Connect RX TX to TX TX; do not replace this connection with a direct power feed from board terminal 10. Set C1 on CX to reopen during closing.
Activating the safety device test
With the power off, move the TX2 wire to TS; RX2/C stay on 2, and the TX link between RX/TX remains in place. Then go to Configuration → Wired safety devices → Safety devices test and activate the test and the corresponding safety input. If the test fails, resolve the issue with the power supply, wiring or configuration; never permanently bypass the safety device.
Safety edges and four inputs
Configure CX, CY, CZ and CK individually. An NC safety edge uses a C–NC contact with no polarity, for example as shown in the DFWN diagram. For a resistive safety edge, select the appropriate R7/R8 mode and use the actual 8K2 wiring diagram; a pair of edges has its own setting and wiring. Do not confuse a resistive safety edge with a standard NC contact.
For a pair of DFWN NC safety edges, both contacts are connected separately in the diagram on the left: C from both edges to board terminal 2, NC from one to CX, and NC from the other to CY. The manufacturer recommends this wiring and identifies it as parallel; configure each input individually. On the right, the NC contacts are wired in series to one input: board terminal 2 → C of the first edge, NC of the first → C of the second, NC of the second → board CX. These are DFWN contact diagrams, not 8K2 resistive safety edge diagrams.
Initial start-up and direction check
- Check the mechanism, end stops, rack, cables, release lock and clearances.
- After switching on, follow the graphical display’s setup wizard. For this operator, select Motor type → BKV2000; changing the type does not change the physical load capacity.
- Set the direction in Configuration → Motor settings → Opening direction. The default direction is left.
- In the Motor test function, the > button closes and the < button opens. If the direction is wrong, correct it in the menu; do not guess by swapping wires.
- Configure STOP, all connected safety inputs and any required test, then run travel learning.
- Check a full cycle, partial opening, all safety devices, lights, radio controls and behavior after a power failure.
The first normal movement after switching on is opening; wait for it to finish. If the operator behaves unusually or makes noise or vibrates, stop it immediately and resolve the cause.
BKV automatic travel learning
Before learning, set the mechanical limit switches, fixed end stops, BKV2000 type and direction correctly. The operator must be locked in place and the entire movement area clear. Monitor the entire procedure; keep people out of the travel path.
- Open Configuration → Motor settings → Travel calibration.
- When prompted with Confirm?, select YES and press ENTER.
- Allow the complete learning wizard displayed on the specific board to run; do not issue another command before it finishes.
- When complete, check the positions, slowdowns and operation of all safety devices. If Calibration error appears, first remove the obstruction or mechanical fault, and only then repeat the learning procedure.
This control board is programmed using the menu labels. Do not transfer the numerical A1/A3 or ZN7 settings from another product series to this unit.
Programming via the graphic display
ENTER opens the menu and confirms the selection. < and > navigate through the items and change the value. ESC cancels an unconfirmed change, goes back, exits the menu, or stops movement. Program the unit while the drive is stationary, and save the current settings before making changes.
Below is an explanation in Slovak with the English menu labels to make it easy to find the relevant item. Bold is used only for factory-set values explicitly identified as such. Feature availability depends on the connected boards and the control board version.
Configuration → Motor settings
| Item / meaning | Options and conditions |
|---|---|
| Opening direction Opening direction. |
To the left – left; To the right – right. |
| Motor test Direction test. |
> closes, < opens; if the direction is incorrect, correct it by selecting the right direction. |
| Travel calibration Travel learning. |
Confirm? NO/YES; learning procedure. |
| Motor type Drive type. |
For the BKV20AGS, select BKV2000; the other options, BKV1500/BKV2500, do not increase this model’s load capacity. |
Configuration → Gate travel settings
Configuration → Wired safety devices
| Item / meaning | Options and conditions |
|---|---|
| Total stop STOP1–2: stops the gate and disables automatic closing. |
Deactivated / On. Activate only with a correctly wired NC contact. |
| CX input / CY input / CZ input / CK input Four separately configurable inputs. |
Each Deactivated; C1/C2/C3/C4/C7/C8/C13/R7/R8 and R7/R8 for two edges. Meanings are listed below the table. |
| Safety devices test Photocell test for opening and closing commands. |
Deactivated / On; requires connection via TS. |
| Obst. with motor stopped When an obstruction is detected, prevents the drive from starting, even from a stationary position. |
Deactivated / On. |
Configuration → RIO safety devices
Configuration → Command inputs / Functions
Configuration → Times / Manage lights
Configuration → RSE communication / External memory
| Item / meaning | Options and conditions |
|---|---|
| RSE1 Card function in RSE_1. |
CRP, Paired or Off. |
| CRP address Unique board address in the system. |
1–254. |
| RSE1 speed / RSE2 speed Baud rate for each port. |
1200/2400/4800/9600/14400/19200/38400/57600/115200 bps.
Default speed for both ports: 38400 bps. |
| Save data Save users, times and configuration. |
Shown when external memory is inserted; Memory Roll. |
| Read data Load saved data onto the board. |
Replaces the board data with the saved configuration; check the entire setup after loading. |
Manage users – users
Information – information and service
| Item / meaning | Options and conditions |
|---|---|
| FW version Display the FW and GUI versions. |
Record both versions before changing the settings. |
| Manoeuvre counter Movement counters. |
Total manoeuvres / Partial manoeuvres. |
| Set up maintenance Service reminder. |
Deactivated or 1×100 to 250×100 manoeuvres; the reminder flashes 3+3 times. |
| Maintenance reset Reset the partial service counter. |
Confirm? NO/YES; perform after actual maintenance. |
| Parameter reset Restore parameters. |
Preserves Radio decoding, Motor type and calibration data; distinguish this from a full reset. |
| Errors list Last 8 errors. |
Use the arrows to browse the history; Delete errors clears it after confirmation. |
Timer management / Commands
Language / Password / F Menu
Responses of wired and RIO inputs
| Response | Meaning |
|---|---|
| C1 / P1 | Reopen while closing – photocells. |
| C2 / P2 | Reclose while opening – photocells. |
| C3 / P3 | Partial stop; check alongside the operating automation. |
| C4 / P4 | Stop and wait for the obstruction to be removed. |
| C7 / P7 | Reopen while closing – safety edges. |
| C8 / P8 | Reclose while opening – safety edges. |
| C13 / P13 | Reopen while closing and stop immediately once the obstruction is removed; this response also applies when the gate is stationary. |
| R7 / R8 | Corresponding response for 8K2-resistance safety edges; separate option for one or two edges. |
| P0 | Stop and disable automatic operation; resume only with a new command. |
Saving and managing remote controls
For the graphic menu described above, the capacity is 250 users. The AF requires a receiver with the correct frequency and coding; one example is AF43S with TOP-432EE. Matching frequencies alone does not confirm compatibility.
- Open Manage users → New user.
- Select the required function and confirm with ENTER.
- Send the code by pressing the selected button on the remote control.
- Repeat the procedure for another button or user, record the number and command, and test the actual operation.
To delete an individual user, select Remove user; to delete all users, select Remove all. Radio decoding → Rolling code or TW Key block erases previously stored transmitters with different coding. Do not use this option unless you have a record of the existing remote controls.
Parameter reset and full reset
Information → Parameter reset restores the factory parameters but preserves Radio decoding, Motor type, and travel calibration settings. Save the configuration before confirming, and after the reset check the direction, safety devices, timings, and operating tests. To delete all users, use the separate option Manage users → Remove all. After each reset, also check the stored remote controls.
Resetting a forgotten password requires a different, full reset. It erases stored users, timings, and calibration. After the reset, the entire system must be recommissioned safely.
- Disconnect power to the control board, including any batteries.
- Press and hold < and > simultaneously, then restore power according to the service procedure.
- Hold the buttons until Factory reset appears, select Confirm YES, and press ENTER.
- Set the correct model and direction again, configure all safety devices, perform the learning procedure, and set up the users; carry out full tests before operation.
Backing up and loading Memory Roll
- Disconnect the mains and batteries, then insert Memory Roll into the designated connector.
- After switching on, select Configuration → External memory → Save data or Read data.
- Saving/loading includes users, timings, and configuration. Loading may overwrite the board's existing data.
- When finished, disconnect the power and remove Memory Roll. After restoring, check that the model, direction, all safety devices, and commands are correct.
These items appear when memory is connected. Use the documented Memory Roll connector; do not connect a USB device to another connector just because the function name looks similar.
Memory Roll is labeled in the image of the actual ZN8 control board with the number 23.
Two operators in MASTER–SLAVE mode
Insert RSE cards into RSE_1 on both boards and connect A–A, B–B, and GND–GND via UTP CAT5 as shown in the diagram. Connect accessories and control devices to the MASTER; users are also stored there. On the MASTER, select Paired in the wizard or in the RSE1 settings; the second operator becomes the SLAVE. The MASTER handles the partial command according to the original diagram; the shared opening command operates both leaves.
If RSE_1 is used for pairing, CRP uses RSE_2. CAME KEY cannot be connected in this configuration. Do not confuse the same letters A/B on different interfaces.
Troubleshooting display messages
| Message | Check / action |
|---|---|
| Calibration error | Learning interrupted by an obstruction; remove the cause and check the mechanics. |
| The Encoder does not work | Encoder disconnected or damaged; with power off, check its specific connector and wiring. |
| Service test failure error | Obstruction at the photocells, incorrect wiring/configuration, or a faulty photocell; check the TS test. |
| Door lock open | The operator is released; check that the lever is secured. |
| Maximum number of closing / opening obstacles / obstacles | The maximum number of consecutive obstructions has been exceeded; remove the resistance or cause of the safety response. |
| Communication error | Incorrectly configured RSE port; check the connection and mode. |
| Incompatible remote control | Incompatible transmitter, coding, or TWIN KEY BLOCK. |
| Slave door open | The SLAVE operator is released. |
| No communication from the RIO system | The RIO module is missing from the connector or is faulty. |
| RIO system not configured | The wireless system or its devices are not configured. |
Information → Errors list stores the last 8 errors. Record the status and FW/GUI before clearing them. If the gate does not move, check the mains supply, fuses, release mechanism, STOP input, safety devices, and any continuously activated command. If it opens but does not close, check the photocells and the relevant input setting. Do not bypass the safety device with a permanent bridge.
Fuses for 230 V BKV20AGS
| Circuit | Fast-acting fuse |
|---|---|
| Mains | 2 A F |
| Control board | 630 mA F |
| Accessories | 1.6 A F |
Check the fuses with the mains and batteries disconnected. Replace them only with the same type and rating, and first eliminate the cause of the short circuit or overload.
Maintenance and servicing
Every 10,000 cycles and at least every 6 months check that screws/nuts are tight, inspect the wear and operation of moving parts, lubricate the relevant mechanical points, and check warning and safety devices, the manual release, cables, guide and rack. Disconnect the power supply and batteries before carrying out any work. After an extended shutdown, check that the entire system operates correctly once mains power is restored.
The manufacturer specifies an MCBF of 250,000 cycles for the BKV20 at 20 m/2,000 kg; in windy areas, the stated figure is reduced by 15%. This is a reference figure for the number of cycles between failures, not a maintenance-free interval or a guarantee of the service life of every gate. Set the service reminder in Information → Set up maintenance and reset it only after servicing has been completed.
After setup, close the board guard, cover and all fasteners. Check the forces and safety functions of the entire gate, show the user how to operate the manual release, and provide the manuals for the complete assembly. Dispose of electronic components and batteries at a designated collection point when decommissioning the unit.
CAME BKV20AGS Technical Specifications
| Parameter | Value for the described configuration |
|---|---|
| Model / code | BKV20AGS / 801MS-0310 |
| Maximum gate leaf weight / length | 2,000 kg / 20 m |
| Mains power supply | 230 V AC, 50/60 Hz |
| Motor / board internal power supply | 36 V DC / 26 V DC |
| Power | 250 W |
| Force / maximum force | 900 N / 1,350 N |
| Maximum speed | 12 m/min |
| Ingress protection rating | IP54 |
| Operating temperature | −20 to +55 °C |
| Operation | Continuous operation; no fixed cycles-per-hour figure. |
| Operating time | 180 s |
| Standby power consumption | 14 W; 0.8 W with the RGP1 module |
| Transformer thermal protection | 120 °C |
| Insulation class / gear ratio | I / 40 |
| Operator weight | 21 kg |
| Colour | Grey RAL 7024 |
| Pinion / limit switches | Module 4 / mechanical |
| Dimensions: width × depth × height | 400 × 260 × 412 mm |
| Model setting | Motor type → BKV2000 |
| User capacity of this menu | 250 |