CAME BKV20AGS – standalone operator for sliding gates up to 2000 kg (A)


Product availability: within 3 days

We usually dispatch goods within 3 days.


CAME BKV20AGS – standalone operator for sliding gates up to 2000 kg (A) CAME BKV20AGS – standalone operator for sliding gates up to 2000 kg (A)
CAME-BKV20AGS-A
within 3 days
€798.11 excluding VAT
€981.68 including VAT

 pcs
Weight
12 kg

Description of CAME BKV20AGS – standalone operator for sliding gates up to 2000 kg (A)

CAME BKV20AGS operator is designed for sliding gates weighing up to 2000 kg and gate leaf length up to 20 m. It has an electromechanical stop switch. The operator is non-reversible. Detailed technical specifications ». Download the manual ».

CAME BKV20AGS, code 801MS-0310, is a drive for a large sliding gate leaf up to 2,000 kg and 20 m long. It has a 36 V DC motor, a graphic display, four wired safety inputs and mechanical limit switches. The mains supply is 230 V AC. Assess the gate's capacity, length and actual resistance together.

Disconnect the mains and any batteries before opening the unit or inserting cards. Check the BKV20AGS label, the ZN8 control board and the FW/GUI version in the Information menu. The settings below are for the graphic menu with Motor type BKV2000 selected. For a different model or menu, refer to its specific manual.

Quick navigation
Standalone drive and kits Accessories
Installation Wiring
Manual release Control board overview
Terminals and power supply Photocells and testing
Initial setup Travel learning
Programming Remote controls
Reset and memory Troubleshooting
Maintenance Technical specifications
Installation PDF manual

Standalone BKV20AGS drive and related kits

Version Selection
CAME BKV20AGS standalone drive (A) A drive for adding to or replacing an assembly; accessories are selected separately.
CAME BKV20AGS kit (D) Alternative kit option. Check the product page for the specific kit to confirm its contents.

20 m is the maximum gate-leaf length; do not confuse it with the clear opening width. The BKV20AGS uses mechanical limit switches. Magnetic limit switches and the clock card included with AGE versions are not standard equipment on the AGS.

Accessories and wiring examples

The following devices are examples of accessories and their wiring, not items included with the standalone drive. For a different type, use its own manual.

Component Example / use
Photocells CAME DIR10, 12/24 V AC/DC; range 10 m, terminals and testing.
Flashing light CAME KLED24, 24 V AC/DC, 2 W; 10–E wiring.
Radio receiver CAME AF43S and TOP-432EE, an example of fixed-code 433.92 MHz; check code compatibility against the control board settings.
Rack Gear racks, module 4 for this model.
Controls Switches, push buttons and readers; volt-free NO commands and NC STOP according to the control board.

Installing the BKV20AGS

Before installation, check that the gate moves easily and smoothly by hand along its entire travel. The gate and guide must be stable, level and secured against derailment. Check that there are solid stops at both the open and closed positions, and protect against crushing, trapping and rack engagement hazards. Mount the drive on a solid surface, away from direct water exposure. If the gate leaf has a pedestrian gate, movement may be enabled only when it is safely secured.

Foundation and anchor plate

The manufacturer's example specifies an excavation measuring 500 × 280 mm, 800 mm deep and Ø 40 mm conduits. Adapt the foundation dimensions to the ground conditions and the specific gate; this is an installation example, not a universal foundation design. The formwork extends 50 mm above ground and contains steel reinforcement.

Example of a BKV foundation and conduit routing
Example of a BKV foundation and conduit routing
Formwork 50 mm above ground and BKV foundation reinforcement
Formwork 50 mm above ground and BKV foundation reinforcement

Insert the supplied M12 bolts into the plate and secure them with nuts. Bend the preformed anchor tabs and place the plate in the reinforcement. The conduits must pass through its openings. Level the plate precisely; the threaded ends must remain above the concrete. The position relative to the rack is based on the dimensions 76 and 96 mm shown in the cross-section. Allow the concrete to cure for at least 24 hours.

Installing the BKV anchor plate and M12 bolts
Installing the BKV anchor plate and M12 bolts
BKV position relative to the rack – dimensions 76 and 96 mm
BKV position relative to the rack – dimensions 76 and 96 mm

Positioning and height adjustment

After removing the formwork, backfill around the foundation. Remove the anchor nuts and pull the cables approximately 600 mm above the plate. Remove the cover and position the drive; the cables pass through its underside and sealed cable glands. Raise the drive using the threaded feet by 5–10 mm, leaving room to adjust the meshing.

Mounting the BKV drive on the anchor plate
Mounting the BKV drive on the anchor plate
Cable gland and BKV height adjustment by 5–10 mm
Cable gland and BKV height adjustment by 5–10 mm

Rack and 1–2 mm clearance

Disengage the drive and fasten the module 4 rack while moving the gate by hand. When joining sections, place a spare rack section under the joint and use two clamps so the teeth align smoothly. Once fastened, adjust the height using the feet and the horizontal position using the slotted holes.

Fastening the module 4 rack and aligning the joints
Fastening the module 4 rack and aligning the joints

Leave 1–2 mm clearance between the pinion and the rack. The gate's weight must not rest on the drive. Move the gate manually through its full travel, and only after adjustment secure the drive to the plate with washers and nuts.

1–2 mm clearance and BKV adjustment relative to the rack
1–2 mm clearance and BKV adjustment relative to the rack
Final fastening of the BKV after adjusting the meshing
Final fastening of the BKV after adjusting the meshing

AGS mechanical limit switches

Open the gate manually. Place the opening limit switch stop on the rack so that its ramp actuates the spring-loaded microswitch, and secure it with the screws supplied. Repeat the same procedure for closing. In the configuration shown, approximately 20 mm is left before the fixed stop; check the run-on distance under the actual load. The fixed gate stop and the drive limit switch stop serve different purposes.

BKV mechanical limit switch stop in the open position
BKV mechanical limit switch stop in the open position
BKV mechanical limit switch stop in the closed position
BKV mechanical limit switch stop in the closed position

Wiring

Circuit Cross-section / condition
230 V AC mains 3G × 1.5 mm² up to 20 m; 3G × 2.5 mm² for 20–30 m.
24 V warning light 2 × 1 mm² for the specified cable runs up to 30 m.
Photocells TX 2 × 0.5 mm²; RX 4 × 0.5 mm² as shown in the full wiring diagram.
Control devices Number of cores according to the device; 0.5 mm² cross-section for the specified cable runs.
Antenna RG58, max. 5 m.
RSE / CRP UTP CAT 5, max. 1,000 m, subject to the requirements of the serial system.

For longer cable runs or multiple loads, recalculate the cross-section based on current and voltage drop. Route the mains supply cable through its own cable gland, separately from the low-voltage circuits. Cables must not touch heated parts or be exposed to mechanical damage.

Manual release and re-engagement

First disconnect the power supply and secure the gate leaf against uncontrolled movement. Do not release a damaged or unbalanced gate unless it has been secured.

  1. Insert the key into the lock and turn it as shown in the top pair of illustrations.
  2. Open the release lever outwards from the housing, in the direction of the arrow.
  3. Move the gate manually and in a controlled manner, keeping people clear of its path.
  4. To re-engage the mechanism, return the lever to its original position and lock it as shown in the bottom pair of illustrations.
  5. Before operating the motor, check that the mechanism is locked again.
BKV – manual release and re-locking
BKV – manual release and re-locking

Orientation on the ZN8 control board

In the following illustration, the board is oriented with the large capacitors at the top, the long terminal blocks at the bottom and the programming buttons on the right. The graphic display and ESC/arrow/ENTER buttons are used for settings, diagnostics and user management. Insert and remove cards only when the mains and any batteries are disconnected.

ZN8 control board – display, terminals and BKV connectors
ZN8 control board – display, terminals and BKV connectors

Illustration number Component
1 / 2 / 3 Motor / encoder / RGP1 or LBB.
4 / 5 / 6 / 7 Programming buttons / RSE / CAME KEY / AF.
8 / 9 / 10 / 11 Antenna / safety devices / serial connection / wired commands.
12 / 13 / 14 / 15 Keypad / transponder / lights / B1–B2.
16 / 17 / 18 / 19 R700 or R800 / RIOCN8WS / clock card / limit switches.
20 / 21 / 22 / 23 / 24 Accessory fuse / control board fuse / transformer / Memory Roll / display.
25 / 26 Mains fuse / mains supply connection on the drive.

BKV20AGS power supply and terminals

Circuit / terminals Voltage, polarity and limit
L / N / PE Mains 230 V AC, 50/60 Hz. L is live, N is neutral and PE is protective earth. AC has no positive or negative polarity.
Motor / control board internal power supply Motor 36 V DC, control board according to the technical table 26 V DC. These are internal circuits in the correct configuration, not an output for accessories. Keep the prescribed wiring; do not connect the mains or an external power supply to them by guesswork.
10 / 11 Accessories 24 V AC/DC, total max. 20 W; normally 24 V AC. For DC 10 = positive (+), 11 = negative (−); no fixed polarity for AC.
10 / E Warning light 24 V AC/DC, max. 3 W. For DC, terminal 10 is positive common and E is the switched output.
10 / E3 Auxiliary light 24 V AC/DC, max. 12 W; set the mode under Manage lights → Light E3. For DC, terminal 10 is positive common and E3 is the switched output.
10 / 5 Status indication 24 V AC/DC, max. 3 W. For DC, terminal 10 is positive common and 5 is the switched output.
B1 / B2 A separate controlled contact with monostable or bistable mode. It does not supply power to accessories via terminals 10/11.
10 / TS / 2 Power supply and tested photocell circuit, and common terminal, as specified in the wiring diagram for the particular configuration; TS is not a universal permanent negative output.

BKV mains connection: L, N and protective earth
BKV mains connection: L, N and protective earth
BKV accessory power supply – terminal 10 positive and 11 negative for DC
BKV accessory power supply – terminal 10 positive and 11 negative for DC

Commands, STOP, safety devices and antenna

Terminals Function / contact
1–2 NC STOP. Stops the gate and disables automatic closing; a new command is required to move it again. If STOP is not used, disable Total stop.
2–3 NO command to open only.
2–3P NO partial-opening command.
2–4 NO command to close only.
2–7 NO step-by-step or sequential command via Command 2-7.
2–CX / CY / CZ / CK Four independently configurable safety inputs. Disable unused inputs; configure used ones according to the protective device.
S1 / GND Transponder or reader with the corresponding R700 card.
A / B on readers Code keypad with R800; do not confuse these with the same letters used for the serial connection.
A / B / GND on RSE Pair’s serial connection or CRP, depending on the connector used.
Antenna / AF Connect the RG58 core to the antenna signal and the shield to the marked ground terminal as shown; plug the radio card into AF.

NO/NC commands and safety contacts are voltage-free and have no +/− polarity. The accessory power supply and its output contact are separate circuits. Do not connect 230 V to the command terminals.

BKV – readers, STOP, commands 2–3/3P/4/7 and antenna
BKV – readers, STOP, commands 2–3/3P/4/7 and antenna

Flashing light and auxiliary light

CAME KLED24 is rated for 24 V AC/DC and 2 W, so connect it to 10–E within the 3 W limit. Its input is not separately marked +/−; polarity does not matter with AC, while with DC, 10 is the board’s positive common terminal. Do not connect a 230 V version of the flashing light here. E3 is a separate light output rated for 12 W; do not confuse E and E3.

Separate BKV outputs: flashing light E, light E3 and signal output 5
Separate BKV outputs: flashing light E, light E3 and signal output 5
24 V supply for the CAME KLED24 flashing light
24 V supply for the CAME KLED24 flashing light

DIR10 photocells and testing via TS

The example uses CAME DIR10: TX/RX pair, 10 m range, 12/24 V AC/DC power supply. Set the RX jumper to 24 V. The pair draws 60 mA at 24 V AC. RX has terminals 10 (+), 2 (−), TX, C and NC. TX has terminals TX and 2, with no separate +/− markings in the original diagram. With AC, DC polarity does not apply.

CAME DIR10 receiver (RX) and transmitter (TX) terminals
CAME DIR10 receiver (RX) and transmitter (TX) terminals
Setting the DIR10 jumper to 24 V
Setting the DIR10 jumper to 24 V

DIR10 terminal Standard With test
RX10 (+) Board 10 Board 10
RX2 (−) and RX C Board 2 Board 2
RX TX ↔ TX TX Connect between RX and TX Same connection
TX2 Board 2 Board TS
RX NC Board CX Board CX

The C–NC contact has no polarity. In this synchronized diagram, RX2 and C connect to board terminal 2, not 11. Connect RX TX to TX TX; do not replace this connection with a direct power feed from board terminal 10. Set C1 on CX to reopen during closing.

BKV – standard DIR / DELTA-S wiring
BKV – standard DIR / DELTA-S wiring

Activating the safety device test

With the power off, move the TX2 wire to TS; RX2/C stay on 2, and the TX link between RX/TX remains in place. Then go to Configuration → Wired safety devices → Safety devices test and activate the test and the corresponding safety input. If the test fails, resolve the issue with the power supply, wiring or configuration; never permanently bypass the safety device.

BKV – DIR / DELTA-S with tested transmitter connected to TS
BKV – DIR / DELTA-S with tested transmitter connected to TS

Safety edges and four inputs

Configure CX, CY, CZ and CK individually. An NC safety edge uses a C–NC contact with no polarity, for example as shown in the DFWN diagram. For a resistive safety edge, select the appropriate R7/R8 mode and use the actual 8K2 wiring diagram; a pair of edges has its own setting and wiring. Do not confuse a resistive safety edge with a standard NC contact.

BKV – DFWN NC safety edge
BKV – DFWN NC safety edge

For a pair of DFWN NC safety edges, both contacts are connected separately in the diagram on the left: C from both edges to board terminal 2, NC from one to CX, and NC from the other to CY. The manufacturer recommends this wiring and identifies it as parallel; configure each input individually. On the right, the NC contacts are wired in series to one input: board terminal 2 → C of the first edge, NC of the first → C of the second, NC of the second → board CX. These are DFWN contact diagrams, not 8K2 resistive safety edge diagrams.

DFWN NC safety edges: separate CX and CY on the left, series connection to CX on the right
DFWN NC safety edges: separate CX and CY on the left, series connection to CX on the right

Initial start-up and direction check

  1. Check the mechanism, end stops, rack, cables, release lock and clearances.
  2. After switching on, follow the graphical display’s setup wizard. For this operator, select Motor type → BKV2000; changing the type does not change the physical load capacity.
  3. Set the direction in Configuration → Motor settings → Opening direction. The default direction is left.
  4. In the Motor test function, the > button closes and the < button opens. If the direction is wrong, correct it in the menu; do not guess by swapping wires.
  5. Configure STOP, all connected safety inputs and any required test, then run travel learning.
  6. Check a full cycle, partial opening, all safety devices, lights, radio controls and behavior after a power failure.

The first normal movement after switching on is opening; wait for it to finish. If the operator behaves unusually or makes noise or vibrates, stop it immediately and resolve the cause.

BKV automatic travel learning

Before learning, set the mechanical limit switches, fixed end stops, BKV2000 type and direction correctly. The operator must be locked in place and the entire movement area clear. Monitor the entire procedure; keep people out of the travel path.

  1. Open Configuration → Motor settings → Travel calibration.
  2. When prompted with Confirm?, select YES and press ENTER.
  3. Allow the complete learning wizard displayed on the specific board to run; do not issue another command before it finishes.
  4. When complete, check the positions, slowdowns and operation of all safety devices. If Calibration error appears, first remove the obstruction or mechanical fault, and only then repeat the learning procedure.

This control board is programmed using the menu labels. Do not transfer the numerical A1/A3 or ZN7 settings from another product series to this unit.

Programming via the graphic display

ENTER opens the menu and confirms the selection. < and > navigate through the items and change the value. ESC cancels an unconfirmed change, goes back, exits the menu, or stops movement. Program the unit while the drive is stationary, and save the current settings before making changes.

BKV graphic display and ESC, arrow, and ENTER buttons
BKV graphic display and ESC, arrow, and ENTER buttons

Below is an explanation in Slovak with the English menu labels to make it easy to find the relevant item. Bold is used only for factory-set values explicitly identified as such. Feature availability depends on the connected boards and the control board version.

Configuration → Motor settings

Item / meaning Options and conditions
Opening direction
Opening direction.
To the left – left; To the right – right.
Motor test
Direction test.
> closes, < opens; if the direction is incorrect, correct it by selecting the right direction.
Travel calibration
Travel learning.
Confirm? NO/YES; learning procedure.
Motor type
Drive type.
For the BKV20AGS, select BKV2000; the other options, BKV1500/BKV2500, do not increase this model’s load capacity.

Configuration → Gate travel settings

Item / meaning Options and conditions
Opening speed
Opening speed.
40–100%; 100%.
Closing speed
Closing speed.
40–100%; 100%.
Opening slowdown speed
Opening slowdown speed.
15–60%; 50%.
Closing slowdown speed
Closing slowdown speed.
15–60%; 50%.
Travel AST control
Sensitivity of obstruction detection during movement.
Deactivated, Minimum, Average, Maximum, Customised.
Slowdown AST control
Sensitivity during slowdown.
Deactivated, Minimum, Average, Maximum, Customised.
Soft start
A brief start at reduced speed.
Deactivated / On.
Part. open point
Partial opening point.
10–100% of travel; 20%.
Opening slowdown point
Start of slowdown when opening.
10–60% of travel; 25%.
Closing slowdown point
Start of slowdown when closing.
10–60% of travel; 25%.

Configuration → Wired safety devices

Item / meaning Options and conditions
Total stop
STOP1–2: stops the gate and disables automatic closing.
Deactivated / On. Activate only with a correctly wired NC contact.
CX input / CY input / CZ input / CK input
Four separately configurable inputs.
Each Deactivated; C1/C2/C3/C4/C7/C8/C13/R7/R8 and R7/R8 for two edges. Meanings are listed below the table.
Safety devices test
Photocell test for opening and closing commands.
Deactivated / On; requires connection via TS.
Obst. with motor stopped
When an obstruction is detected, prevents the drive from starting, even from a stationary position.
Deactivated / On.

Configuration → RIO safety devices

Item / meaning Options and conditions
RIO ED T1 / RIO ED T2
Two wireless safety edges, available with the RIO interface.
Each Disabled; P0 stops the gate and disables automatic operation, P7 reopens during closing, P8 recloses during opening.
RIO PH T1 / RIO PH T2
Two wireless photocell channels.
Each Disabled; P1/P2/P3/P4/P13, depending on the relevant safety response.

Configuration → Command inputs / Functions

Item / meaning Options and conditions
Command 2-7
Main NO command mode.
Step-by-step (open/close) / Sequential (open–STOP–close–STOP).
Hold-to-run
Movement occurs only while the corresponding control is held down.
Deactivated / On. The gate stops when the control is released; when this function is active, the other control devices are disabled.
B1-B2 output
Standalone contact mode.
Bistable / Monostable; monostable switching for 1–180 s.
Removing obstacles
Clearance after activation of the safety edge or current sensing.
Deactivated / On. When On, the movement briefly reverses to clear the obstacle; when deactivated, it reverses all the way to the end position.

Configuration → Times / Manage lights

Item / meaning Options and conditions
Automatic close
Delay after fully opening.
Deactivated or 1–180 s. Automatic closing is not activated after a STOP command, a safety device detecting an obstacle, or a power failure.
Automatic partial close
Delay after partial opening.
Off or 1–180 s; 10 s. The main Automatic close function must not be deactivated.
Gate-open warning light
Status output 10–5.
Warning light on: on during movement and while open; Warning light flashing: flashes during movement and stays on while open.
Light E3
Separate auxiliary light.
Deactivated, Cycle lamp or Courtesy light. The cycle lamp requires automatic operation to be enabled.
Courtesy time
Lighting duration.
60–180 s; 60 s.
Pre-flashing time
Beacon pre-flash duration.
Deactivated or 1–10 s.

Configuration → RSE communication / External memory

Item / meaning Options and conditions
RSE1
Card function in RSE_1.
CRP, Paired or Off.
CRP address
Unique board address in the system.
1–254.
RSE1 speed / RSE2 speed
Baud rate for each port.
1200/2400/4800/9600/14400/19200/38400/57600/115200 bps.

Default speed for both ports: 38400 bps.

Save data
Save users, times and configuration.
Shown when external memory is inserted; Memory Roll.
Read data
Load saved data onto the board.
Replaces the board data with the saved configuration; check the entire setup after loading.

Manage users – users

Item / meaning Options and conditions
New user
Add a user.
Up to 250; assign Step-by-step, Sequential, Open, Partially open or B1-B2 output.
Remove user
Delete one user.
Enter a number from 1–250 or activate the user's device, press ENTER, then answer Confirm? if prompted. YES; CLr confirms deletion.
Remove all
Delete all users.
Confirm? NO/YES.
Radio decoding
Enabled radio coding.
All decodings / Rolling code / TW Key block. Selecting a restricted mode deletes other codes previously stored.
Sensor type
Type of control sensor.
Keypad or Transponder with the corresponding decoding card.
Change mode
Change the command assigned to a user.
Select the user by number or device, press ENTER, choose a new command, then confirm with YES.

Information – information and service

Item / meaning Options and conditions
FW version
Display the FW and GUI versions.
Record both versions before changing the settings.
Manoeuvre counter
Movement counters.
Total manoeuvres / Partial manoeuvres.
Set up maintenance
Service reminder.
Deactivated or 1×100 to 250×100 manoeuvres; the reminder flashes 3+3 times.
Maintenance reset
Reset the partial service counter.
Confirm? NO/YES; perform after actual maintenance.
Parameter reset
Restore parameters.
Preserves Radio decoding, Motor type and calibration data; distinguish this from a full reset.
Errors list
Last 8 errors.
Use the arrows to browse the history; Delete errors clears it after confirmation.

Timer management / Commands

Item / meaning Options and conditions
Show clock
Display the clock.
Requires a compatible clock card to be physically installed.
Set the clock
Set the date and time.
Use the arrows and ENTER.
Automatic DST
Automatic daylight saving time change.
Deactivated / On.
Time format
Time format.
24-hour /12-hour.
Create new timer
Create a timer.
Open / Partially open / Output B1-B2; set the start, end, and days, or the whole week.
Remove timer
Remove the saved timer.
Select 0 – open, P – partial opening, or B – output B1-B2; confirm.
Commands
Test commands from the display.
Open / Partially open / Close / Stop; confirm with ENTER only when the area is secure.

Language / Password / F Menu

Item / meaning Options and conditions
Language
Display language.
IT/EN/FR/DE/ES/PT/PL/RU; Slovak or Czech is not listed here.
Enable password
Main menu protection.
Enter a 4-digit password and confirm it again.
Remove password
Remove the password.
Confirm? NO/YES.
Change password
Change the password.
Enter the new 4-digit code and repeat it.
F Menu
Enable the display of F functions.
This is an alternative display for this control board; do not use numerical options from other series.

Responses of wired and RIO inputs

Response Meaning
C1 / P1 Reopen while closing – photocells.
C2 / P2 Reclose while opening – photocells.
C3 / P3 Partial stop; check alongside the operating automation.
C4 / P4 Stop and wait for the obstruction to be removed.
C7 / P7 Reopen while closing – safety edges.
C8 / P8 Reclose while opening – safety edges.
C13 / P13 Reopen while closing and stop immediately once the obstruction is removed; this response also applies when the gate is stationary.
R7 / R8 Corresponding response for 8K2-resistance safety edges; separate option for one or two edges.
P0 Stop and disable automatic operation; resume only with a new command.

Saving and managing remote controls

For the graphic menu described above, the capacity is 250 users. The AF requires a receiver with the correct frequency and coding; one example is AF43S with TOP-432EE. Matching frequencies alone does not confirm compatibility.

  1. Open Manage users → New user.
  2. Select the required function and confirm with ENTER.
  3. Send the code by pressing the selected button on the remote control.
  4. Repeat the procedure for another button or user, record the number and command, and test the actual operation.

To delete an individual user, select Remove user; to delete all users, select Remove all. Radio decoding → Rolling code or TW Key block erases previously stored transmitters with different coding. Do not use this option unless you have a record of the existing remote controls.

Parameter reset and full reset

Information → Parameter reset restores the factory parameters but preserves Radio decoding, Motor type, and travel calibration settings. Save the configuration before confirming, and after the reset check the direction, safety devices, timings, and operating tests. To delete all users, use the separate option Manage users → Remove all. After each reset, also check the stored remote controls.

Resetting a forgotten password requires a different, full reset. It erases stored users, timings, and calibration. After the reset, the entire system must be recommissioned safely.

  1. Disconnect power to the control board, including any batteries.
  2. Press and hold < and > simultaneously, then restore power according to the service procedure.
  3. Hold the buttons until Factory reset appears, select Confirm YES, and press ENTER.
  4. Set the correct model and direction again, configure all safety devices, perform the learning procedure, and set up the users; carry out full tests before operation.

Backing up and loading Memory Roll

  1. Disconnect the mains and batteries, then insert Memory Roll into the designated connector.
  2. After switching on, select Configuration → External memory → Save data or Read data.
  3. Saving/loading includes users, timings, and configuration. Loading may overwrite the board's existing data.
  4. When finished, disconnect the power and remove Memory Roll. After restoring, check that the model, direction, all safety devices, and commands are correct.

These items appear when memory is connected. Use the documented Memory Roll connector; do not connect a USB device to another connector just because the function name looks similar.

Memory Roll is labeled in the image of the actual ZN8 control board with the number 23.

Two operators in MASTER–SLAVE mode

Insert RSE cards into RSE_1 on both boards and connect A–A, B–B, and GND–GND via UTP CAT5 as shown in the diagram. Connect accessories and control devices to the MASTER; users are also stored there. On the MASTER, select Paired in the wizard or in the RSE1 settings; the second operator becomes the SLAVE. The MASTER handles the partial command according to the original diagram; the shared opening command operates both leaves.

If RSE_1 is used for pairing, CRP uses RSE_2. CAME KEY cannot be connected in this configuration. Do not confuse the same letters A/B on different interfaces.

BKV – RSE_1 connection between MASTER and SLAVE
BKV – RSE_1 connection between MASTER and SLAVE

Troubleshooting display messages

Message Check / action
Calibration error Learning interrupted by an obstruction; remove the cause and check the mechanics.
The Encoder does not work Encoder disconnected or damaged; with power off, check its specific connector and wiring.
Service test failure error Obstruction at the photocells, incorrect wiring/configuration, or a faulty photocell; check the TS test.
Door lock open The operator is released; check that the lever is secured.
Maximum number of closing / opening obstacles / obstacles The maximum number of consecutive obstructions has been exceeded; remove the resistance or cause of the safety response.
Communication error Incorrectly configured RSE port; check the connection and mode.
Incompatible remote control Incompatible transmitter, coding, or TWIN KEY BLOCK.
Slave door open The SLAVE operator is released.
No communication from the RIO system The RIO module is missing from the connector or is faulty.
RIO system not configured The wireless system or its devices are not configured.

Information → Errors list stores the last 8 errors. Record the status and FW/GUI before clearing them. If the gate does not move, check the mains supply, fuses, release mechanism, STOP input, safety devices, and any continuously activated command. If it opens but does not close, check the photocells and the relevant input setting. Do not bypass the safety device with a permanent bridge.

Fuses for 230 V BKV20AGS

Circuit Fast-acting fuse
Mains 2 A F
Control board 630 mA F
Accessories 1.6 A F

Check the fuses with the mains and batteries disconnected. Replace them only with the same type and rating, and first eliminate the cause of the short circuit or overload.

Maintenance and servicing

Every 10,000 cycles and at least every 6 months check that screws/nuts are tight, inspect the wear and operation of moving parts, lubricate the relevant mechanical points, and check warning and safety devices, the manual release, cables, guide and rack. Disconnect the power supply and batteries before carrying out any work. After an extended shutdown, check that the entire system operates correctly once mains power is restored.

The manufacturer specifies an MCBF of 250,000 cycles for the BKV20 at 20 m/2,000 kg; in windy areas, the stated figure is reduced by 15%. This is a reference figure for the number of cycles between failures, not a maintenance-free interval or a guarantee of the service life of every gate. Set the service reminder in Information → Set up maintenance and reset it only after servicing has been completed.

After setup, close the board guard, cover and all fasteners. Check the forces and safety functions of the entire gate, show the user how to operate the manual release, and provide the manuals for the complete assembly. Dispose of electronic components and batteries at a designated collection point when decommissioning the unit.

CAME BKV20AGS Technical Specifications

Parameter Value for the described configuration
Model / code BKV20AGS / 801MS-0310
Maximum gate leaf weight / length 2,000 kg / 20 m
Mains power supply 230 V AC, 50/60 Hz
Motor / board internal power supply 36 V DC / 26 V DC
Power 250 W
Force / maximum force 900 N / 1,350 N
Maximum speed 12 m/min
Ingress protection rating IP54
Operating temperature −20 to +55 °C
Operation Continuous operation; no fixed cycles-per-hour figure.
Operating time 180 s
Standby power consumption 14 W; 0.8 W with the RGP1 module
Transformer thermal protection 120 °C
Insulation class / gear ratio I / 40
Operator weight 21 kg
Colour Grey RAL 7024
Pinion / limit switches Module 4 / mechanical
Dimensions: width × depth × height 400 × 260 × 412 mm
Model setting Motor type → BKV2000
User capacity of this menu 250

CAME BKV20AGS dimensional drawing
CAME BKV20AGS dimensional drawing

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about CAME BKV20AGS – standalone operator for sliding gates up to 2000 kg (A)

Product: CAME BKV20AGS – standalone operator for sliding gates up to 2000 kg (A)
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.