CAME BKV15AGS – standalone drive unit for a sliding gate up to 1500 kg (A)


Product availability: within 3 days

We usually dispatch goods within 3 days.


CAME BKV15AGS – standalone drive unit for a sliding gate up to 1500 kg (A) CAME BKV15AGS – standalone drive unit for a sliding gate up to 1500 kg (A)
CAME-BKV15AGS-A
within 3 days
€717.11 excluding VAT
€882.05 including VAT

 pcs
Weight
12 kg

Description of CAME BKV15AGS – standalone drive unit for a sliding gate up to 1500 kg (A)

CAME BKV15AGS gate operator is designed for sliding gates with a weight of up to 1,500 kg and a gate leaf length of up to 20 m. It features an electromechanical stop switch. The operator is non-reversible. Detailed technical specifications ». Download the manual ».

CAME BKV15AGS, code 801MS-0300, is a gate operator for a large sliding gate leaf up to 1,500 kg and 20 m long. It has a 36 V DC motor, a graphic display, four wired safety inputs and mechanical limit switches. The mains supply is 230 V AC. Consider the gate’s weight, length and actual resistance together.

Disconnect the mains and any batteries before opening the unit or inserting cards. Check the BKV15AGS label, ZBKN board and FW/GUI version in the Information menu. The settings below are for the graphic menu with the Motor type BKV1500 option. For a different version or menu, use the manual specific to that version.

Quick navigation
Standalone gate operator Accessories
Installation Wiring
Manual release Board overview
Terminals and power supply Photocells and testing
First startup Travel learning
Programming Remote controls
Reset and memory Diagnostics
Maintenance Technical specifications
Installation manual PDF

CAME BKV15AGS standalone gate operator

This manual is for the CAME BKV15AGS standalone gate operator (A). For the version with accessories, see the CAME BKV15AGS kit listing.

The 20 m value is the maximum gate-leaf length; do not confuse it with the clear opening width. The BKV15AGS uses mechanical limit switches. Magnetic limit switches and the timer card included with AGE versions are not standard equipment on the AGS.

Accessories and wiring examples

The devices below are specific examples for the wiring shown. Check the standalone operator’s package contents and confirm which accessories are actually supplied in the specific listing; for a different model, use its own manual.

Component Example / use
Photocells CAME DIR10, 12/24 V AC/DC; range 10 m, terminals and testing.
Flashing light CAME KLED24, 24 V AC/DC, 2 W; wiring to 10–E.
Radio CAME AF43S and TOP-432EE, example of a fixed code at 433.92 MHz; check code compatibility with the board settings.
Rack Toothed racks, module 4 for this model.
Controls Switches, push buttons and readers; voltage-free NO commands and NC STOP, as specified for the board.

Installing the BKV15AGS

Before installation, check that the gate moves easily and smoothly by hand along its entire travel. The gate and its guide must be stable and level, with no risk of the gate coming off the guide. Check that there are solid stops in both the open and closed positions, and guard against crushing, trapping and rack-engagement hazards. Secure the operator to a solid base, away from direct water flow. If the gate leaf has a pedestrian gate, movement may be enabled only when it is safely secured.

Foundation and anchor plate

The manufacturer’s example specifies an excavation 500 × 280 mm, 800 mm deep and Ø 40 mm conduits. Adapt the foundation dimensions to the ground conditions and the specific gate; this is an installation example, not a universal foundation design. The formwork extends 50 mm above ground and contains steel reinforcement.

Example of a BKV foundation and conduit routing
Example of a BKV foundation and conduit routing
Formwork 50 mm above ground and BKV foundation reinforcement
Formwork 50 mm above ground and BKV foundation reinforcement

Insert the supplied M12 bolts into the plate and secure them with nuts. Bend the preformed anchor tabs away and place the plate in the reinforcement. The conduits must pass through its openings. Level the plate precisely; the threaded ends must remain above the concrete. The position relative to the rack is based on the dimensions 76 and 96 mm shown in the cross-section. Allow the concrete to cure for at least 24 hours.

Installing the BKV anchor plate and M12 bolts
Installing the BKV anchor plate and M12 bolts
BKV position relative to the rack – dimensions 76 and 96 mm
BKV position relative to the rack – dimensions 76 and 96 mm

Positioning and height adjustment

After removing the formwork, backfill around the foundation. Remove the anchor nuts and pull the cables to approximately 600 mm above the plate. Remove the cover and position the operator; the cables pass through its underside and sealed cable glands. Use the threaded feet to raise the operator by 5–10 mm, leaving room to adjust the gear mesh.

Positioning the BKV operator on the anchor plate
Positioning the BKV operator on the anchor plate
Cable gland and BKV height adjustment by 5–10 mm
Cable gland and BKV height adjustment by 5–10 mm

Rack and 1–2 mm clearance

Release the operator and fasten the module 4 rack while moving the gate by hand. When joining rack sections, place a spare rack section underneath the joint and use two clamps to keep the teeth aligned smoothly. After fastening, adjust the height using the feet and the horizontal position using the slotted holes.

Fastening the module 4 rack and aligning the joints
Fastening the module 4 rack and aligning the joints

Leave 1–2 mm of clearance between the pinion and rack. The weight of the gate must not rest on the operator. Move the gate through its full travel by hand and, once adjusted, secure the operator to the plate with washers and nuts.

1–2 mm clearance and BKV adjustment relative to the rack
1–2 mm clearance and BKV adjustment relative to the rack
Final fastening of the BKV after adjusting the gear mesh
Final fastening of the BKV after adjusting the gear mesh

AGS mechanical limit switches

Open the gate manually. Fit the opening limit-switch tab to the rack so that its ramp actuates the spring-loaded microswitch, then secure it with the supplied screws. Repeat the same procedure at the closing position. In the assembly shown, approximately 20 mm before the fixed stop; check the run-on distance under the actual load. The gate’s fixed stop and the drive’s limit stop serve different functions.

BKV mechanical limit stop at opening
BKV mechanical limit stop at opening
BKV mechanical limit stop at closing
BKV mechanical limit stop at closing

Wiring

Circuit Cross-section / condition
230 V AC mains 3G × 1.5 mm² up to 20 m; 3G × 2.5 mm² for 20–30 m.
24 V beacon 2 × 1 mm² for the specified cable runs up to 30 m.
Photocells TX 2 × 0.5 mm²; RX 4 × 0.5 mm², according to the complete wiring diagram.
Control devices Number of cores according to the device; 0.5 mm² cross-section for the specified cable runs.
Antenna RG58, maximum 5 m.
RSE / CRP UTP CAT 5, maximum 1,000 m, subject to the conditions of the serial system.

For a longer cable run or multiple loads, recalculate the cross-section based on the current and voltage drop. Route the mains supply cable through its own conduit, separate from the low-voltage circuits. Cables must not touch heated parts or be exposed to mechanical damage.

Manual release and re-engagement

First disconnect the power supply and secure the gate leaf to prevent uncontrolled movement. Do not release a damaged or unbalanced gate without securing it first.

  1. Insert the key into the lock and turn it as shown in the top pair of images.
  2. Open the release lever away from the housing, in the direction of the arrow.
  3. Move the gate manually and under control, with no one in its path.
  4. To re-engage the mechanism, return the lever to its original position and lock it as shown in the bottom pair of images.
  5. Before issuing a motor command, check that the mechanism is secured again.
BKV – manual release and relocking
BKV – manual release and relocking

Orientation on the ZBKN board

In the following image, the board is oriented with the large capacitors at the top, the long terminal blocks at the bottom and the programming buttons on the right. The graphical display and ESC/arrow/ENTER buttons are used for setup, diagnostics and user management. Insert and remove cards only when the mains power and any batteries are disconnected.

ZBKN board – display, terminals and BKV connectors
ZBKN board – display, terminals and BKV connectors

Image number Component
1 / 2 / 3 Motor / encoder / RGP1 or LBB.
4 / 5 / 6 / 7 Programming buttons / RSE / CAME KEY / AF.
8 / 9 / 10 / 11 Antenna / safety / serial connection / wired commands.
12 / 13 / 14 / 15 Keypad / transponder / lights / B1–B2.
16 / 17 / 18 / 19 R700 or R800 / RIOCN8WS / clock card / limit switches.
20 / 21 / 22 / 23 / 24 Accessory fuse / board fuse / transformer / Memory Roll / display.
25 / 26 Mains fuse / mains supply connection on the drive.

BKV15AGS power supply and terminals

Circuit / terminals Voltage, polarity and limit
L / N / PE Mains 230 V AC, 50/60 Hz. L is the live wire, N the neutral wire, and PE the protective earth. AC has no positive or negative polarity.
Motor / internal board power supply Motor 36 V DC, board according to the technical table 26 V DC. These are internal circuits of the correct assembly, not an output for accessories. Keep them connected as specified; do not connect mains power or an external power supply to them by guesswork.
10 / 11 Accessories 24 V AC/DC, 20 W maximum in total; typically 24 V AC. For DC 10 = positive (+), 11 = negative (−); no fixed polarity for AC.
10 / E Beacon 24 V AC/DC, max. 3 W. For DC, 10 is the positive common terminal and E is the switched output.
10 / E3 Auxiliary light 24 V AC/DC, max. 12 W; mode in Manage lights → Light E3. For DC, 10 is the positive common terminal and E3 is the switched output.
10 / 5 Status indication 24 V AC/DC, max. 3 W. For DC, 10 is the positive common terminal and 5 is the switched output.
B1 / B2 Separate controlled contact with monostable or bistable mode. It does not power accessories via 10/11; check the documentation for the specific board for load connections and permitted ratings.
10 / TS / 2 Photocell power supply and tested circuit, with common terminal as shown in the specific wiring diagram; TS is not a universal permanent negative output.

BKV mains connection: L, N and protective earth
BKV mains connection: L, N and protective earth
BKV accessory power supply – 10 positive and 11 negative for DC
BKV accessory power supply – 10 positive and 11 negative for DC

Commands, STOP, safety and antenna

Terminals Function / contact
1–2 NC STOP. Stops the gate and disables automatic closing; a new command is required to move it again. If STOP is not used, deactivate Total stop.
2–3 NO command: open only.
2–3P NO partial opening.
2–4 NO command: close only.
2–7 NO step-by-step or sequential command, according to Command 2-7.
2–CX / CY / CZ / CK Four independently configurable safety inputs. Deactivate unused inputs; configure those in use according to the safety devices.
S1 / GND A transponder or reader with the corresponding R700 card.
A / B on readers Code keypad with R800; do not confuse with the same letters used for the serial connection.
A / B / GND on RSE Pair serial connection or CRP, depending on the corresponding connector.
Antenna / AF RG58 core for the antenna signal, shielding to the marked ground terminal as shown; plug-in radio card into AF.

NO/NC commands and safety contacts are voltage-free, with no +/− polarity. The accessory power supply and its output contact are separate circuits. Do not connect 230 V to the command terminals.

BKV – readers, STOP, commands 2–3/3P/4/7 and antenna
BKV – readers, STOP, commands 2–3/3P/4/7 and antenna

Flashing light and auxiliary light

CAME KLED24 is rated at 24 V AC/DC and 2 W, so it should be connected to 10–E within the 3 W limit. Its input is not separately marked +/−; polarity is irrelevant with AC, while with DC, 10 is the board's positive common terminal. Do not connect a 230 V version of the flashing light here. E3 is a separate light output with a 12 W limit; do not confuse E and E3.

Separate BKV outputs: flashing light E, light E3 and signal 5
Separate BKV outputs: flashing light E, light E3 and signal 5
24 V supply for CAME KLED24 flashing light
24 V supply for CAME KLED24 flashing light

DIR10 photocells and testing via TS

The example is for CAME DIR10: TX/RX pair, 10 m range, 12/24 V AC/DC power supply. Set the RX jumper to 24 V. The pair draws 60 mA at 24 V AC. RX has terminals 10 (+), 2 (−), TX, C and NC. TX has terminals TX and 2, with no separate +/− markings in the original diagram. With AC, DC polarity does not apply.

CAME DIR10 receiver RX and transmitter TX terminals
CAME DIR10 receiver RX and transmitter TX terminals
Setting the DIR10 jumper to 24 V
Setting the DIR10 jumper to 24 V

DIR10 terminal Standard With test
RX10 (+) Board10 Board10
RX2 (−) and RX C Board2 Board2
RX TX ↔ TX TX Connect between RX and TX Same connection
TX2 Board2 BoardTS
RX NC BoardCX BoardCX

The C–NC contact has no polarity. In this synchronized diagram, RX2 and C are connected to board terminal 2, not 11. Connect RX TX to TX TX; do not replace this connection with direct power from board terminal 10. Set C1 on CX to reopen during closing.

BKV – standard DIR / DELTA-S wiring
BKV – standard DIR / DELTA-S wiring

Enabling the safety test

With the power off, move the TX2 wire to TS; RX2/C remain on 2, and the TX connection between RX/TX remains in place. Then go to Configuration → Wired safety devices → Safety devices test enable the test and the corresponding safety input. If the test fails, fix the power supply, wiring or configuration issue; never permanently bypass the safety device.

BKV – DIR / DELTA-S with transmitter tested via TS
BKV – DIR / DELTA-S with transmitter tested via TS

Safety edges and four inputs

Configure CX, CY, CZ and CK individually. An NC edge uses a C–NC contact with no polarity, for example as shown in the DFWN diagram. For a resistive edge, select the appropriate R7/R8 mode and the actual 8K2 wiring; a pair of edges has its own selection and wiring. Do not confuse a resistive edge with a standard NC contact.

BKV – DFWN NC safety edge
BKV – DFWN NC safety edge

For a pair of DFWN NC edges, both contacts are connected separately in the left-hand diagram: C of both edges to board terminal 2, NC of one to CX and NC of the other to CY. The manufacturer recommends and identifies this as parallel wiring; each input must be configured individually. On the right, the NC contacts are wired in series to one input: board terminal 2 → C of the first edge, NC of the first → C of the second, NC of the second → board CX. These are DFWN contact diagrams, not 8K2 resistive edge diagrams.

DFWN NC edges: separate CX and CY on the left, series connection to CX on the right
DFWN NC edges: separate CX and CY on the left, series connection to CX on the right

Initial startup and checking the direction

  1. Check the mechanics, end stops, rack, cables, release lock and clear space.
  2. After switching on, follow the graphical display wizard. For this operator, select Motor type → BKV1500; changing the type does not change the physical load capacity.
  3. Set the direction in Configuration → Motor settings → Opening direction. The default direction is to the left.
  4. In the Motor test function, the > button closes and the < button opens. If the direction is incorrect, correct it in the menu; do not guess and swap the wires.
  5. Set STOP, all connected safety inputs and any required test, then run the travel learning procedure.
  6. Check a full cycle, partial opening, all safety devices, lights, radio and behavior after a power outage.

The first normal movement after power-up is opening; wait for it to finish. If you notice unusual behavior, noise or vibration, stop immediately and fix the cause.

Automatic BKV travel learning

Before learning, the mechanical limit switches, fixed end stops, BKV1500 type and direction must be set correctly. The operator must be locked in place and the entire movement area clear. Supervise the entire procedure; no one may enter the travel path.

  1. Open Configuration → Motor settings → Travel calibration.
  2. When asked “Confirm?”, select YES and press ENTER.
  3. Let the entire learning wizard shown on the specific board run; do not issue another command prematurely.
  4. When complete, check the positions, deceleration and operation of all safety devices. If “Calibration error” appears, first remove any obstruction or fix the mechanical fault, then repeat the learning procedure.

This graphical board is programmed using menu names. Do not transfer numerical A1/A3 settings or ZN7 settings from another product line to this one.

Programming via the graphical display

ENTER opens the menu and confirms the selection. < and > scroll through the items and change the value. ESC cancels an unconfirmed change, goes back, exits the menu or stops movement. Program the drive while it is stationary, and save the current settings before making changes.

BKV graphic display and ESC, arrow and ENTER buttons
BKV graphic display and ESC, arrow and ENTER buttons

Below is the explanation in Slovak, with the English menu names included so you can locate each item unambiguously. In bold are only the factory values explicitly specified. Feature availability depends on the connected cards and the control board version.

Configuration → Motor settings

Item / description Options and conditions
Opening direction
Opening direction.
To the left – left; To the right – right.
Motor test
Direction test.
> closes, < opens; if the direction is wrong, correct it by selecting the appropriate direction.
Travel calibration
Travel learning.
Confirm? NO/YES; learning procedure.
Motor type
Drive type.
For the BKV15AGS, select BKV1500; the other options, BKV2000/BKV2500, do not increase the load capacity of this model.

Configuration → Gate travel settings

Item / description Options and conditions
Opening speed
Opening speed.
40–100 %; 100 %.
Closing speed
Closing speed.
40–100 %; 100 %.
Opening slowdown speed
Opening slowdown speed.
15–60 %; 50 %.
Closing slowdown speed
Closing slowdown speed.
15–60 %; 50 %.
Travel AST control
Sensitivity of obstacle detection during movement.
Deactivated, Minimum, Average, Maximum, Customised.
Slowdown AST control
Sensitivity during slowdown.
Deactivated, Minimum, Average, Maximum, Customised.
Soft start
Brief start-up at reduced speed.
Deactivated / On.
Part. open point
Partial opening point.
10–100 % of travel; 20 %.
Opening slowdown point
Opening slowdown start point.
10–60 % of travel; 25 %.
Closing slowdown point
Closing slowdown start point.
10–60 % of travel; 25 %.

Configuration → Wired safety devices

Item / description Options and conditions
Total stop
STOP1–2: stops movement and disables automatic closing.
Deactivated / On. Activate only with the correct NC contact.
CX input / CY input / CZ input / CK input
Four independently configurable inputs.
Each Deactivated; C1/C2/C3/C4/C7/C8/C13/R7/R8 and R7/R8 for two safety edges. Descriptions below the table.
Safety devices test
Tests the photocells during opening and closing commands.
Deactivated / On; requires connection via TS.
Obst. with motor stopped
When an obstacle is detected, prevents the motor from starting, even from a stationary state.
Deactivated / On.

Configuration → RIO safety devices

Item / description Options and conditions
RIO ED T1 / RIO ED T2
Two wireless safety edges, available with the RIO interface.
Each Disabled; P0 stops movement and disables automatic operation, P7 reopens during closing, P8 recloses during opening.
RIO PH T1 / RIO PH T2
Two wireless photocell channels.
Each Disabled; P1/P2/P3/P4/P13, depending on the relevant safety response.

Configuration → Command inputs / Functions

Item / description Options and conditions
Command 2-7
Main NO command mode.
Step-by-step (open/close) / Sequential (open–STOP–close–STOP).
Hold-to-run
Movement occurs only while the relevant control is held.
Deactivated / On. Stops when released; when this function is active, all other control devices are disabled.
B1-B2 output
Standalone contact mode.
Bistable / Monostable; monostable contact closure for 1–180 s.
Removing obstacles
Clearance after activation of the edge or current sensing.
Deactivated / On. When On, briefly reverse movement to release the obstruction; when deactivated, reverse all the way to the end position.

Configuration → Times / Manage lights

Item / description Options and conditions
Automatic close
Wait time after fully opening.
Deactivated or 1–180 s. Automatic closing will not take place after STOP, safety activation due to an obstruction, or a power failure.
Automatic partial close
Wait time after partially opening.
Off or 1–180 s; 10 s. The main Automatic close function must not be deactivated.
Gate-open warning light
Status output 10–5.
Warning light on: on during movement and while open; Warning light flashing: flashes during movement and stays on while open.
Light E3
Separate auxiliary light.
Deactivated, Cycle lamp or Courtesy light. Cycle lamp requires the automatic function to be set.
Courtesy time
Lighting duration.
60–180 s; 60 s.
Pre-flashing time
Pre-flashing time for the warning light.
Deactivated or 1–10 s.

Configuration → RSE communication / External memory

Item / description Options and conditions
RSE1
Role of the card in RSE_1.
CRP, Paired or Off.
CRP address
Unique board address in the system.
1–254; do not guess the default.
RSE1 speed / RSE2 speed
Transmission speed for each port.
1200/2400/4800/9600/14400/19200/38400/57600/115200 bps.
Save data
Save users, times and configuration.
Displayed when memory is inserted; Memory Roll.
Read data
Load saved data onto the board.
Replaces the board data with the saved configuration; check the entire system after loading.

Manage users – users

Item / description Options and conditions
New user
Add a user.
Maximum 250; assign Step-by-step, Sequential, Open, Partially open or B1-B2 output.
Remove user
Delete one user.
Enter number 1–250 or activate the user's device, press ENTER and answer the Confirm? prompt if shown. YES; CLr confirms deletion.
Remove all
Delete all users.
Confirm? NO/YES.
Radio decoding
Permitted radio encoding.
All decodings / Rolling code / TW Key block. Selecting a restricted mode deletes other encodings previously stored.
Sensor type
Type of control sensor.
Keypad or Transponder with the corresponding decoding card.
Change mode
Change the command assigned to a user.
Select the user by number or device, press ENTER, choose the new command and confirm with YES.

Information – information and service

Item / description Options and conditions
FW version
Display both FW and GUI versions.
Record both versions before changing settings.
Manoeuvre counter
Movement counters.
Total manoeuvres / Partial manoeuvres.
Set up maintenance
Service reminder.
Deactivated or 1×100 to 250×100 manoeuvres; the warning flashes 3+3 times.
Maintenance reset
Reset the partial service counter.
Confirm? NO/YES; do this after actual maintenance.
Parameter reset
Restore parameters.
Preserves Radio decoding, Motor type and calibration data; distinguish this from a full reset.
Errors list
Last 8 errors.
Use the arrows to browse the history; Delete errors clears it after confirmation.

Timer management / Commands

Item / description Options and conditions
Show clock
Display the clock.
Requires a correctly matched clock card to be physically installed.
Set the clock
Set the date and time.
Use the arrows and ENTER.
Automatic DST
Automatic daylight saving time change.
Deactivated / On.
Time format
Time format.
24-hour / 12-hour.
Create new timer
Create a timer.
Open / Partially open / Output B1-B2; set the start and end times and the days, or the whole week.
Remove timer
Delete a saved timer.
Select 0 – open, P – partially open or B – output B1-B2; confirm.
Commands
Test commands from the display.
Open / Partially open / Close / Stop; press ENTER to confirm only when the area is secure.

Language / Password / F Menu

Item / meaning Options and conditions
Language
Display language.
IT/EN/FR/DE/ES/PT/PL/RU; Slovak or Czech is not listed here.
Enable password
Main menu protection.
Enter a 4-digit password and confirm it again.
Remove password
Remove the password.
Confirm? NO/YES.
Change password
Change the password.
Enter and repeat the new 4-digit code.
F Menu
Enable the display of F functions.
This is an alternative display for this control board; do not use numerical options from other series.

Responses of wired and RIO inputs

Response Meaning
C1 / P1 Reopening during closing – photocells.
C2 / P2 Reclosing during opening – photocells.
C3 / P3 Partial stop; check in conjunction with the operating automation.
C4 / P4 Stop and wait for the obstacle to be removed.
C7 / P7 Reopening during closing – safety edges.
C8 / P8 Reclosing during opening – safety edges.
C13 / P13 Reopen during closing and stop immediately once the obstacle is removed; this response also applies when the gate is stationary.
R7 / R8 Corresponding response for 8K2 resistance safety edges; separate option for one or two edges.
P0 Stop and disable the automation; operation can resume only with a new command.

Storing and managing remote controls

For the graphical menu described above, the capacity is 250 users. The AF slot requires a receiver with the correct frequency and encoding; one example is AF43S with TOP-432EE. Matching frequencies alone do not confirm compatibility.

  1. Open Manage users → New user.
  2. Select the required function and press ENTER to confirm.
  3. Transmit the code using the selected button on the remote control.
  4. Repeat the procedure for another button or user, record the number and command, and test the actual operation.

Use Remove user to delete an individual user, or Remove all to delete all users. Radio decoding → Rolling code or TW Key block deletes transmitters previously stored with different encoding. Do not try this option unless you have a record of the existing remote controls.

Parameter reset and full reset

Information → Parameter reset restores the factory parameters but retains Radio decoding, Motor type and travel calibration settings. Save the configuration before confirming, and after the reset check the direction, safety devices, timings and operating tests. To delete all users, use the separate option Manage users → Remove all. After each reset, also verify the stored remote controls.

Recovery after forgetting the password is a separate full reset. It deletes stored users, timings and calibration. After the reset, the entire system must be recommissioned safely.

  1. Disconnect power to the control board, including any batteries.
  2. Press and hold < and > simultaneously, then restore power as directed by the service procedure.
  3. Keep the buttons pressed until Factory reset appears, select Confirm YES and press ENTER.
  4. Set the correct model and direction again, configure all safety devices, perform learning and add users; carry out complete tests before operation.

Backing up and loading a Memory Roll

  1. Disconnect the mains and batteries, then insert the Memory Roll into the marked connector.
  2. After switching on, select Configuration → External memory → Save data or Read data.
  3. Saving/loading includes users, timings and configuration. Loading may overwrite the board's existing data.
  4. When complete, disconnect the power and remove the Memory Roll. After restoring, verify the model, direction, all safety devices and commands.

These items appear when memory is connected. Use the specified Memory Roll connector; do not connect a USB device to another connector just because the function name looks similar.

In the picture, the Memory Roll of the actual ZBKN board is marked with number 23.

Two operators in MASTER–SLAVE mode

Insert RSE cards into RSE_1 on both boards and connect A–A, B–B and GND–GND via UTP CAT5, as shown in the diagram. Connect accessories and control devices to the MASTER; users are also stored there. On the MASTER, select Paired in the wizard or in the RSE1 settings; the second operator becomes the SLAVE. The MASTER controls partial opening according to the original diagram; the shared opening command opens both leaves.

If RSE_1 is used for the pair, CRP uses RSE_2. CAME KEY cannot be connected in this configuration. Do not confuse the same A/B letters on different interfaces.

BKV – RSE_1 connection between MASTER and SLAVE
BKV – RSE_1 connection between MASTER and SLAVE

Troubleshooting display messages

Message Check / procedure
Calibration error Learning interrupted by an obstacle; remove the cause and check the mechanics.
The Encoder does not work Encoder disconnected or damaged; with the power off, check its specific connector and wiring.
Service test failure error Obstacle at the photocells, faulty wiring/configuration or a faulty photocell; check the TS test.
Door lock open The operator is released; check that the lever is secured.
Maximum number of closing / opening obstacles / obstacles The maximum number of consecutive detected obstacles has been exceeded; remove the resistance or cause triggering the safety device.
Communication error Incorrect RSE port setting; check the connection and mode.
Incompatible remote control Transmitter, encoding or TWIN KEY BLOCK does not match.
Slave door open The SLAVE operator is released.
No communication from the RIO system The RIO module is missing from the connector or is faulty.
RIO system not configured The wireless system or its devices are not configured.

Information → Errors list stores the last 8 errors. Record the status and FW/GUI before clearing them. If the gate does not move, check the mains supply, fuses, release mechanism, STOP, safety devices and any continuously active command. If it opens but does not close, check the photocells and the relevant input setting. Do not bypass the safety device with a permanent bridge.

Fuses for 230 V BKV15AGS

Circuit Fast-acting fuse
Mains 2 A F
Control board 630 mA F
Accessories 1.6 A F

Check the fuses with the mains and batteries disconnected. Replace them only with fuses of the same type and rating, and first eliminate the cause of the short circuit or overload.

Maintenance and servicing

Every 10,000 cycles and at least every 6 months check that screws/nuts are tight, inspect the wear and operation of moving parts, lubricate the relevant mechanical points, and check warning and safety devices, the manual release, cables, guide and rack. Disconnect the power supply and batteries before carrying out any work. After an extended period out of service, check that the system operates correctly once the mains supply is restored.

The manufacturer specifies an MCBF of 250,000 cycles for the BKV15 at 20 m/1,500 kg; in windy areas, this figure is reduced by 15%. This is a reference figure for the interval between failures, not a maintenance-free interval or a guarantee of the service life of every gate. Set the maintenance reminder under Information → Set up maintenance, and reset it only after servicing has been completed.

After making adjustments, close the control board cover, housing and all fasteners. Check the forces and safety functions of the entire gate, show the user how to operate the manual release, and provide the manuals for the complete assembly. Take the electronics and batteries to a designated collection point when disposing of them.

CAME BKV15AGS technical specifications

Parameter Value for the described configuration
Model / code BKV15AGS / 801MS-0300
Maximum gate leaf weight / length 1,500 kg / 20 m
Mains supply 230 V AC, 50/60 Hz
Motor / control board internal supply 36 V DC / 26 V DC
Power 200 W
Force / maximum force 800 N / 1,200 N
Maximum speed 12 m/min
Ingress protection rating IP54
Operating temperature −20 to +55 °C
Operation Continuous operation; no fixed number of cycles per hour.
Operating time 180 s
Standby power consumption 14 W; 0.8 W with the RGP1 module
Transformer thermal protection 120 °C
Insulation class / gear ratio I / 40
Drive unit weight 20 kg
Colour Grey RAL 7024
Pinion / limit switches Module 4 / mechanical
Dimensions: width × depth × height 400 × 260 × 412 mm
Model setting Motor type → BKV1500
User capacity for this menu 250

CAME BKV15AGS dimensional drawing
CAME BKV15AGS dimensional drawing

How can I order this item?

Choose the option that suits you:

  1. order online: use the buy button to add the goods to your shopping cart (you will find the buy button here in the product variants table).
  2. order by email: place your order at [email protected]

Ask us anything about CAME BKV15AGS – standalone drive unit for a sliding gate up to 1500 kg (A)

Product: CAME BKV15AGS – standalone drive unit for a sliding gate up to 1500 kg (A)
Name:
Email:
Phone:
Message:
This page is protected by Google reCAPTCHA.