How to configure two Robus/Run motors as master and slave units

The procedure is as follows:

  1. Disconnect the drives from the power supply
  2. Connect the BlueBus terminals with a two-core cable (left hole to left hole, right to right).
    BlueBus polarity when connecting two opposing Nice Robus RBS drives
  3. If necessary, set the gate opening direction using the switch on the control unit.
    Selecting the direction of movement on the MCU1
  4. Connect to the power supply
  5. Set the subordinate unit mode on the subordinate unit (you have 10 seconds for each step):
    1. Press and hold the STOP/SET button; when L1 starts flashing, release it.
    2. Press the CLOSE button seven times, until the flashing LED moves to position L8.
    3. Press the STOP/SET button once. The L8 LED will change its flashing frequency and then remain lit (or L1+L2 or L3+L4 may flash).
    4. Done.
  6. Detect the connected devices on the subordinate unit:
    1. Press and hold OPEN and STOP/SET; when L1+L2 start flashing rapidly together, release them.
    2. They will stop flashing after a short while. Done.
  7. Detect the connected devices on the master unit:
    1. Press and hold OPEN and STOP/SET; when L1+L2 start flashing rapidly together, release them.
    2. They will stop flashing after a short while. Done.
  8. Detect the movement of the gate leaves on the master unit:
    1. Press and hold STOP/SET and CLOSE; when L3+L4 start flashing rapidly together, release them.
    2. The drives should open and close the gates. Then L3+L4 will go out, and you're done. The Slave will move as well.