Connecting photocells to the NICE Wide barrier

Barrier gates NICE Wide use conventional hardwired technology, so in principle they are compatible with all relay-type photocells powered by 24V. Wide barrier gates are not compatible with photocells using BlueBus technology.

Photocells always come in pairs: a transmitter (TX) and a receiver (RX). Photocells are divided into three types:

There is also:

Disconnect the barrier gate from the power supply before wiring the photocells. If you are not wiring photocells, install jumpers in the control unit between terminals 6 and 11, and between terminals 6 and 12.

Wiring wired photocells

The TX photocell is wired using a 2×0.5m2, and the RX photocell is wired using a 4×0.5m2. In theory, you can, instead of running a wire from terminal 4 on the RX photocell to terminal 6 on the control unit, fit a jumper between terminals 1 and 4 on the photocell, allowing you to use a three-core cable only.

Wire the photocells as follows:

  • Connect terminal 1 on each photocell to terminal 6 on the control unit.
  • Connect terminal 2 on each photocell to terminal 5 on the control unit.
  • Connect terminal 4 on the RX photocell to terminal 6 on the control unit.
  • Connect terminal 5 on the RX photocell to terminal 11 on the control unit.

Wiring one wired and one wireless photocell

This essentially applies only to NICE FT210 photocells. One photocell is connected using a four-core cable, while the other is battery-powered.

Wire the NICE FT210 photocells to a NICE Wide barrier gate as follows:

  1. Disconnect the barrier gate from the power supply.
  2. Set the jumpers on the TX photocell as follows:
    • Jumper J1 – removed (if the photocells are more than 7m apart, insert it)
    • Jumper J2 – removed
    • Jumper J3 – removed
  3. Set the jumpers on the RX photocell as follows:
    • Jumper J1 – removed
    • Jumper J2 – inserted
  4. Connect the wires as follows (photocell terminals are numbered from top to bottom):
    • From terminal no. 6 (+24V) on the Wide barrier gate to terminal no. 10 (+24V) on the RX photocell
    • From terminal no. 5 (-0V) on the Wide barrier gate to terminal no. 9 (-0V) on the RX photocell
    • From terminal no. 11 (PHOTO) on the Wide barrier gate to terminal no. 1 (PHOTO) on the RX photocell
    • From terminal no. 6 (+24V) on the Wide barrier gate to terminal no. 2 (COM) on the RX photocell
  5. Restore power to the operator.

The LEDs on the RX photocell should be lit as follows (from left to right):

  • LED 1 – green, should be lit
  • LED 2 – red, should not be lit
  • LED 3 – yellow, should not be lit
  • LED 4 – red; the slower it flashes, the better the visibility, or the diagnostic sequence

Wiring a reflector photocell

The only model is NICE EPMOR. The photocell, which contains both the TX transmitter and RX receiver, is wired on one side; there is only a reflector on the other side of the passage. Wiring procedure:

  1. Disconnect the barrier gate from the power supply.
  2. See figure 2 on page 2 of the manual https://fortamigo.ie/data/manualy-k-pohonom/fortamigo.ie-NICE-EPMOR.pdf There are three jumpers: J1, J2 and J3. Set them as follows:
    1. If the barrier opening is wider than 4m, remove jumper J1; if it is narrower, leave it in place.
    2. Set jumper J2 to the NC position, i.e. it should be on the top two pins, leaving the bottom pin free.
    3. Leave jumper J3 inserted; this means we will operate without a photocell test.
  3. Connect the wiring as follows:
    1. From terminal 6 on the control unit to terminal 3 on the photocell
    2. From terminal 5 on the control unit to terminal 4 on the photocell
    3. From terminal 11 on the control unit to terminal 6 on the photocell
    4. From terminal 6 on the control unit to terminal 5 on the photocell
  4. Reconnect the barrier gate to the power supply; it should now work.

Wiring multiple pairs of photocells

If you need to connect multiple pairs of photocells to a NICE Wide barrier, they will share a power supply, and their safety circuits should be wired in series. This means wiring the safety circuit between terminals 6 and 11 on the control unit as follows: connect terminal 6 on the control unit to terminal 4 on the first RX photocell; then connect terminal 5 on that photocell to terminal 4 on the second RX photocell; finally, connect terminal 5 on the second photocell to terminal 11 on the control unit.

This way, if the beam between any pair is interrupted, the safety circuit is also interrupted, causing the barrier gate to stop and begin opening.

Protecting the area where the barrier opens with photocells

If for any reason you also need photocells that respond while the barrier is opening, you can wire them in the same way as standard photocells; their safety circuit simply connects between terminals 6 and 12.